2 – Roof- Units A,B
2.2.1 – Roof Covering
Roof Covering 1
HVAC EQUIPMENT NO LONGER IN USE
ROOF

There was an old roof top heating system located on the roof that was no longer in use, and may to be removed in the future. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
2.3.1 – Flashing
Flashing 1
WALL FLASHING IMPROPERLY SEALED
ROOF

Wall flashing appears to be improperly sealed. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

Roofing Professional
2.4.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS
GUTTERS

Gutters were full of debris in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Gutter Contractor
2.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
INADEQUATE CLEARANCE – ROOF
ROOF

One or more combustion appliance exhaust flue(s) ( no longer in use) did not extend far enough above the roof. To ensure proper draw, furnace flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally). Correction could include the addition of a flue extension to encourage proper draft.  A qualified contractor should evaluate and repair/replace as necessary.

Roofing Professional
2.6.2 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 2
MISSING – CAP
ROOF

Flue Pipe (no longer in use) cap is missing. Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
2.6.3 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 3
TOO CLOSE TO WINDOW
ROOF

A flue pipe ( no longer in use) and a plumbing vent (still active), were located to close to an openable window. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
3 – Roof – Unit C
3.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
Roof Covering 3
DAMAGED/DETERIORATED
ROOF

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
3.2.2 – Roof Covering
Roof Covering 4
PATCHED AND SEALED
ROOF

The roof covering material shows signs of previous patches and sealing.

Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
3.3.1 – Flashing
Flashing 1
Flashing 2
WALL FLASHING DAMAGED
ROOF

Wall flashing was damaged. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

Roofing Professional
3.4.1 – Roof Drainage Systems
Roof Drainage Systems 1
BENT/DAMAGED
GUTTERS

Gutters were bent and/or damaged at the time of the inspection.

This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Gutter Contractor
3.4.2 – Roof Drainage Systems
Roof Drainage Systems 2
Roof Drainage Systems 3
DEBRIS IN GUTTERS
GUTTERS

Gutters were full of debris in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Gutter Contractor
3.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
Flue Gas Vent Pipes 2
CORRODED
ROOF

One or more combustion appliance exhaust flue(s) exhibited heavy corrosion.  A qualified contractor should evaluate and repair/replace as necessary.

Qualified Professional
3.6.2 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 3
Flue Gas Vent Pipes 4
Flue Gas Vent Pipes 5
INADEQUATE CLEARANCE – ROOF
ROOF

One or more combustion appliance exhaust flue(s) did not extend far enough above the roof. To ensure proper draw, furnace flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally). Correction could include the addition of a flue extension to encourage proper draft.  A qualified contractor should evaluate and repair/replace as necessary.

Roofing Professional
3.6.3 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 6
LEANING FLUE
ROOF

Flue pipe was leaning at the time of inspection. Flue pipe may not be supported correctly. Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
 
4 – Roof – Unit D
4.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
Roof Covering 3
DAMAGED/DETERIORATED
ROOF

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
4.2.2 – Roof Covering
Roof Covering 4
PATCHED AND SEALED
ROOF

The roof covering material shows signs of previous patches and sealing. Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
4.4.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 1
DEBRIS IN GUTTERS
GUTTERS

Gutters were full of debris in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Gutter Contractor
4.4.2 – Roof Drainage Systems
Roof Drainage Systems 2
MISSING GUTTERS
GUTTERS

The gutters were missing in areas.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
4.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
INADEQUATE CLEARANCE – ROOF
ROOF

One or more combustion appliance exhaust flue(s) did not extend far enough above the roof. To ensure proper draw, furnace flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally). Correction could include the addition of a flue extension to encourage proper draft.  A qualified contractor should evaluate and repair/replace as necessary.

Roofing Professional
4.6.2 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 2
DENTED OR DAMAGED – CAP
ROOF

Flue Pipe cap is excessively dented or damaged. Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
5 – Attic, Insulation & Ventilation – Unit D
5.4.1 – Insulation in Attic
Insulation in Attic 1
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
5.6.1 – Electrical Wiring In Attic
Electrical Wiring In Attic 1
JUNCTION BOX MISSING COVER PLATE

Splice/Junction box was missing a cover plate. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
6 – Exterior – Units A,B,C
6.2.1 – Walkways & Driveways
Walkways & Driveways 1
Walkways & Driveways 2
Walkways & Driveways 3
DETERIORATED
WALKWAYS

The driveway/walkway was deteriorated or was eroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Concrete Contractor
6.2.2 – Walkways & Driveways
Walkways & Driveways 4
HEAVING AND/OR SETTLING
WALKWAYS

The driveway/walkway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Driveway Contractor
6.2.3 – Walkways & Driveways
Walkways & Driveways 5
Walkways & Driveways 6
NOT SEALED PROPERLY
WALKWAYS

A walkway was not properly sealed against a foundation wall and may allow excess moisture to enter. Recommend a qualified contractor and repair or replace as needed.

Qualified Professional
6.2.4 – Walkways & Driveways
Walkways & Driveways 7
MODERATE CRACKING – WALKWAY
WALKWAYS

There were signs of moderate cracking at the walkways. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Concrete Contractor
6.2.5 – Walkways & Driveways
Walkways & Driveways 8
MINOR CRACKING – DRIVEWAY
DRIVEWAY

Minor cracking was visible at the driveway. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary.

Concrete Contractor
6.2.6 – Walkways & Driveways
Walkways & Driveways 9
MINOR CRACKING – WALKWAYS
WALKWAYS

Minor cracking was visible at the walkways in areas.  Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary.

Concrete Contractor
6.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
CRACKING AND MOVEMENT
EXTERIOR

Cracking as well as movement was present in the siding at the time of  inspection.

Monitoring the masonry walls of the house is needed. Although masonry can deform elastically over long periods of time to accommodate small amounts of movement, large movements normally cause cracking.

Cracking can result from a variety of problems:

  • Differential settlement of the foundation
  • Drying shrinkage
  • Expansion and contraction due to ambient thermal and moisture variations
  • Improper support over openings
  • The effects of freeze-thaw cycles
  • The corrosion of iron and steel wall reinforcement
  • Differential movement between building materials; expansion of salts
  • The bulging or leaning of walls.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Qualified Professional
6.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
Wall-Covering, Flashing & Trim 5
MISSING – SIDING
EXTERIOR

The siding or trim was missing in one or more areas. Recommend a qualified contractor evaluate and replace as needed.

Qualified Professional
6.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 6
Wall-Covering, Flashing & Trim 7
PEELING PAINT
EXTERIOR

Peeling paint was present in areas around the property. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
6.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 8
Wall-Covering, Flashing & Trim 9
TUCK POINTING NEEDED
EXTERIOR

A common maintenance task for brick masonry is repair of mortar joints. The longevity of mortar joints will vary with the exposure conditions and the mortar materials used, but a life span of more than 25 years is typical. The longevity of brick, however, may well exceed 100 years. Consequently, occasional repair of the mortar joints is expected over the life of the brick masonry. It is our observation that the most common reason for repointing brick masonry is to improve water penetration resistance. Repointing deteriorated mortar joints is one of the most effective and permanent ways of decreasing water entry into brickwork. This is because the most common means of water entry into a brick masonry wall is through de-bonded, cracked or deteriorated mortar joints. A qualified contractor should evaluate and repair all areas as necessary.

Qualified Professional
6.5.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
NEGATIVE GRADING
EXTERIOR

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

Landscaping Contractor
6.5.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 3
TREE BRANCHES OVER PROPERTY
EXTERIOR

Large trees near the house have branches which overhang the property. Falling branches due to conditions such as wood decay, high winds or heavy snow loads may cause injury, death or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

Tree Service
6.6.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
Eaves, Soffits & Fascia 2
DAMAGED – EAVES
EXTERIOR

The eave(s) were damaged and showed signs of repairs in one or more areas. A qualified contractor should evaluate and repair or replace as necessary.

General Contractor
6.6.2 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
GAPS AT INTERSECTIONS
EXTERIOR

The eaves had gaps at the edges between soffit panels or roof sheathing which allows insects to enter the attic. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
6.6.3 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 2
PEELING PAINT
EXTERIOR

The paint was peeling or cracking in one or more areas of the eaves. A qualified contractor should evaluate and repair or replace as necessary.

Painting Contractor
6.8.1 – Electrical Fixtures
Electrical Fixtures 1
LOOSE WIRES/JUNCTION
EXTERIOR

There was a loose junction box with exposed wires (tested and no longer live) at the rear of the building. A qualified contractor should evaluate and repair or replace as necessary.

Electrical Contractor
6.10.1 – Windows
Windows 1
CRACKED – GLASS WINDOWPANE
EXTERIOR

At least one window had cracked glass or cracked windowpane. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Window Repair and Installation Contractor
6.10.2 – Windows
Windows 2
WOOD ROT AT WINDOWS
EXTERIOR

Exterior windows have trim or framing appears to have wood rot in areas. This may represent a general lack of maintenance or potential water intrusion issues. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Handyman
6.13.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
COULDN’T REMOVE GARDEN HOSE
EXTERIOR

The outside water faucet is connected to a garden hose. The hose could not be removed to inspect the faucet’s current operation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Qualified Professional
6.16.1 – Exterior Foundation Wall
Exterior Foundation Wall 1
Exterior Foundation Wall 2
CRACK – SETTLEMENT
EXTERIOR

The exterior foundation wall had settlement crack(s.) A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
6.16.2 – Exterior Foundation Wall
Exterior Foundation Wall 3
Exterior Foundation Wall 4
Exterior Foundation Wall 5
LOOSE/MISSING – BLOCK & MORTAR
EXTERIOR

The exterior foundation wall has loose or missing block and mortar in areas. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
6.20.1 – Roof Drainage System – Downspouts & Extensions
Roof Drainage System - Downspouts & Extensions 1
Roof Drainage System - Downspouts & Extensions 2
MISSING – EXTENSIONS
EXTERIOR

Downspout(s) are missing extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Qualified Professional
7 – Exterior – Unit D
7.2.1 – Walkways & Driveways
Walkways & Driveways 1
Walkways & Driveways 2
MAJOR CRACKING – DRIVEWAY

There were signs of indications of major cracking at the driveway. This condition could be a trip hazard. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Concrete Contractor
7.10.1 – Windows
Windows 1
DAMAGED – FRAME

The window frame was damaged. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8 – Interior, Doors, Windows – Units A,B
8.2.1 – Ceilings & Walls
Ceilings & Walls 1
DAMAGED – CEILINGS

The ceilings showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.3.1 – Floors
Floors 1
SEAMS WIDE/INCONSISTENT

The flooring had seams that were wide or inconsistent possibly indication loose flooring or poor installation.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.4.1 – Doors
Doors 1
DAMAGE – HANDLE

The door had a damaged handle.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.4.2 – Doors
Doors 2
MISSING – HANDLE/KNOB
MECHANICAL CLOSET

The door was missing a handle or knob.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.5.1 – Windows
Windows 1
Windows 2
STUCK SHUT

The window had a sash that was unable to be opened without excessive force, possibly from being painted or nailed shut.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.6.1 – Electrical Outlets
Electrical Outlets 1
Electrical Outlets 1
MISSING – FACEPLATE

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
EXPOSED WIRING – LIGHT FIXTURE

The light fixture had exposed splices or electrical conductors. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.8.1 – Stairways & Railings
Stairways & Railings 1
MISSING – HANDRAIL

At the interior stairs, the handrail was missing.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
SMOKE DETECTOR IMPROPER LOCATION

The smoke detector was installed improperly. Smoke detectors should be installed on the ceiling, or installed on the wall no more than 12 inches from the ceiling.  A qualified person should repair or replace according to current standards. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

DIY
9 – Interior, Doors, Windows – Unit C
9.2.1 – Ceilings & Walls
Ceilings & Walls 1
Ceilings & Walls 2
MINOR CRACKS-CEILING
BACK BATHROOM

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
9.2.2 – Ceilings & Walls
Ceilings & Walls 3
MINOR CRACKS-WALLS
KITCHEN

Minor cracking was visible on the interior walls.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
9.2.3 – Ceilings & Walls
Ceilings & Walls 4
PAINT PEELING
KITCHEN

The paint was peeling in areas.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
9.3.1 – Floors
Floors 1
CARPET STAINS

The carpet was stained in areas. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
9.3.2 – Floors
Floors 2
CARPET REVEALED A SEAM
LIVING ROOM

The carpet revealed a seam.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
9.3.3 – Floors
Floors 3
SLOPED
KITCHEN

Floor has a dip or is sloped in areas.

Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
9.6.1 – Electrical Outlets

Electrical Outlets 1

Electrical Outlets 2

NOT GROUNDED – OUTLET
THROUGHOUT PROPERTY

One or more electrical outlets were not grounded. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
9.8.1 – Stairways & Railings
Stairways & Railings 1
MISSING – HANDRAIL

At the interior stairs, the handrail was missing.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
9.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
SMOKE DETECTOR MISSING

The smoke detector was missing. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

Qualified Professional
10 – Interior, Doors, Windows – Unit D
10.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
FLICKERING LIGHT

The light fixture flickered possibly indicating a loose connection at the switch or fixture.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
11 – Bathroom – Unit A
11.2.1 – Exhaust Fan
NOT PRESENT – FAN NEEDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
11.4.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 2
MISSING – COVER/GLASS

The light fixture was missing cover/glass. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
11.4.2 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 3
MISSING – BULB

The light fixture was missing one or more bulbs. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
11.6.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
NOT WORKING – SINK STOPPER

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
11.11.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
Fixture Valve Installation And Temperature 2
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate the mixing valve (safety feature to limit potential scalding) needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
12 – Bathroom – Unit B
12.2.1 – Exhaust Fan
Exhaust Fan 1
NOT PRESENT – FAN NEEDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
12.4.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB

One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
12.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
12.5.2 – Cabinets & Counters
Cabinets & Counters 2
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years.

A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
12.5.3 – Cabinets & Counters
Cabinets & Counters 3
LOOSE – CABINETRY

The base cabinetry was loose and not securely fastened to the wall.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
12.5.4 – Cabinets & Counters
Cabinets & Counters 4
CABINET DOES NOT OPEN COMPLETELY

The barbershop bathroom cabinet did not open completely. The door in the toilet.

Qualified Professional
12.6.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
LEAKING

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
12.7.1 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 1
CORRODED

The water supply valve was corroded at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
12.8.1 – Plumbing Fixtures
Plumbing Fixtures 1
DIFFICULT TO OPERATE – CONTROL VALVE

The shower/tub control lever or knob was difficult to operate.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
12.11.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate the mixing valve (safety feature to limit potential scalding) needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
13 – Bathroom – Unit C
13.2.1 – Exhaust Fan
Exhaust Fan 1
DIRTY

The bathroom exhaust fan was was very dirty and clogged.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
13.3.1 – Electrical Outlets
Electrical Outlets 1
NOT GROUNDED – GFCI OUTLET

A GFCI outlet was not grounded and did not trip when tested. A GFCI requires a ground wire to route electricity when tripped. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
13.4.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
MISSING – COVER/GLASS

The light fixture was missing cover/glass. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
13.6.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
NOT WORKING – TUB STOPPER

The drain stop did not work or did not hold water in the tub.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
 
14 – Bathroom – Unit D
14.4.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
FLICKERED
BATHROOM

The light fixture flickered possibly indicating a loose connection at the switch or fixture.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
15 – Kitchen – Unit C
15.7.1 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 1
NO HOT WATER
The kitchen sink did not provide hot water at the time of the inspection. A qualified plumber should investigate and repair or replace as necessary.
Qualified Professional
15.9.1 – Dishwasher
Dishwasher 1
DID NOT CLOSE

The dishwasher door did not close properly.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
15.11.1 – Range Hood
Range Hood 1
LIGHT DID NOT WORK

The vent hood light was not working at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
 
16 – Kitchen – Unit D
16.2.1 – Cabinets & Counters
Cabinets & Counters 1
NOT SMOOTH – CABINET/DRAWERS
One or more cabinet or drawer does not operate smoothly. This could be an issue with the drawer not sliding on a proper guide track or a door being difficult to swing open/closed.

A qualified contractor should evaluate and repair or replace as necessary.

Cabinet Contractor
16.9.1 – Dishwasher
Dishwasher 1
Dishwasher 2
NOT FILLING WITH WATER

The dishwasher was not filling with water when on.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
16.11.1 – Range Hood
Range Hood 1
LIGHT DID NOT WORK

The vent hood light was not working at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
17 – Heating – Unit A
17.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

Qualified Professional
17.6.1 – Cabinet
Cabinet 1
CORRODED, RUSTED

The heating system cabinet was corroded, rusted or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

HVAC Professional
17.9.1 – Air Filter
Air Filter 1
DIRTY

The HVAC system air filter was dirty. Clogged filters can restrict air flow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing filter, as well as cleaning, servicing and evaluating of the HVAC system by a qualified HVAC professional and repair or replace as necessary.

Qualified Professional
17.12.1 – Heating System Ignition & Operation
HEATING SYSTEM NOT OPERATIONAL

The heating system did not respond to demand for heat or did not function properly at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.

HVAC Professional
 
18 – Heating – Unit B
18.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

Qualified Professional
18.6.1 – Cabinet
Cabinet 1
CORRODED, RUSTED

The heating system cabinet was corroded, rusted or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

HVAC Professional
18.9.1 – Air Filter
Air Filter 1
MISSING

The HVAC system air filter was missing. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict air flow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing filter, as well as cleaning, servicing and evaluating of the HVAC system by a qualified HVAC professional and repair or replace as necessary.

HVAC Professional
 
19 – Heating – Unit C
19.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

Qualified Professional
19.6.1 – Cabinet
Cabinet 1
CORRODED, RUSTED

The heating system cabinet was corroded, rusted or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

HVAC Professional
19.9.1 – Air Filter
Air Filter 1
DIRTY

The HVAC system air filter was dirty. Clogged filters can restrict air flow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing filter, as well as cleaning, servicing and evaluating of the HVAC system by a qualified HVAC professional and repair or replace as necessary.

Qualified Professional
 
20 – Heating – Unit D
20.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

Qualified Professional
20.9.1 – Air Filter
Air Filter 2
NOT SECURED

The HVAC system air filter was not properly secured. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict air flow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing filter, as well as cleaning, servicing and evaluating of the HVAC system by a qualified HVAC professional and repair or replace as necessary.

HVAC Professional
20.11.1 – Thermostat & Normal Operating Controls
Thermostat & Normal Operating Controls 1
THERMOSTAT INOPERABLE

The thermostat was inoperable. A qualified contractor should evaluate and repair or replace as necessary.

HVAC Professional
22 – Laundry – Unit D
22.6.1 – 220 Volt Dryer Outlet
220 Volt Dryer Outlet 1
NOT WORKING

The 220-volt dryer electrical outlet was damaged not working.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
22.8.1 – Dryer Vent Piping
Dryer Vent Piping 1
NO VENT CONNECTION

No vent connection was provided for the dryer. Lack of proper dryer venting to the exterior may result in excessively high humidity levels which can damage property materials or components and may encourage the growth of microbes such as mold. Lack of proper dryer venting can also result in the accumulation of lint in the property. Lint is combustible and it’s accumulation is a potential fire hazard and a possible health hazard from the inhalation of particulates. The Inspector recommends proper installation of an Underwriter’s Laboratory (UL) approved dryer vent for safety reasons. Dryer vents should be clean annually to ensure that safe conditions continue to exist.

Qualified Professional
 
23 – Plumbing
23.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
CORROSION – DISTRIBUTION LINE
PLUMBING

The distribution piping runs from the main source to each faucet or fixture. The water distribution supply pipe was corroded. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
23.3.2 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 2
GALVANIZED
PLUMBING

The property contained galvanized steel water distribution pipes. These pipes are outdated and subject to corrosion which will eventually result in restricted flow and leakage and will need to be replaced. Water flow in the property was satisfactory at the time of the inspection.

Qualified Professional
 
24 – Electrical – Unit A
24.5.1 – Electrical Circuit Breakers
Electrical Circuit Breakers 1
DOUBLE TAP
ELECTRICAL PANEL

One or more circuit breakers have two wires that are connected to a breaker designed for only one wire. This is known as a “double-tap” and is a defective condition. A qualified contractor should evaluate and repair or replace as necessary.

Electrical Contractor
 
25 – Electrical – Unit B
25.2.1 – Distribution Panels
Distribution Panels 1
PUSHMATIC
ELECTRICAL PANEL

The sub panel for unit B was manufactured by a company named “Pushmatic”. These panels are obsolete and often when replacing breakers/parts the entire panel will need to be replaced, due to the fact that  parts cannot be found. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
25.3.1 – Main Service Shut-Off
Main Service Shut-Off 1
SERVICE RATING – BELOW 100AMPS
ELECTRICAL PANEL

Determining the electrical service capacity is outside the scope of a general home inspection according to the InterNACHI (International Association of Certified Home Inspectors) standards of practice. The inspector does not measure/calculate the amperage or voltage of the property according to these standards.

The size of the service to the property was 70 amps which is the below the minimum for modern day electrical demands. 200 amp is the current standard on most newer homes/buildings. If additional electrical components need to be added, it may require updating and replacing the main electrical panel. If this is a concern or the client requires additional information the inspector would recommend contacting a qualified electrical contractor to further evaluate before the inspection objection period.

Electrical Contractor
25.5.1 – Electrical Circuit Breakers
Electrical Circuit Breakers 1
Electrical Circuit Breakers 2
DOUBLE TAP
ELECTRICAL PANEL

One or more circuit breakers have two wires that are connected to a breaker designed for only one wire. This is known as a “double-tap” and is a defective condition. A qualified contractor should evaluate and repair or replace as necessary.

Electrical Contractor
26 – Electrical – Unit C
26.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS
ELECTRICAL PANEL

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power to. Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

Electrical Contractor
26.2.2 – Distribution Panels
Distribution Panels 2
OPEN KNOCKOUT – BREAKER
ELECTRICAL PANEL

Unused circuit-breaker panel opening was missing filler plate. A qualified contractor should evaluate and repair and replace as necessary.

Electrical Contractor
26.6.1 – Electrical Wiring
Electrical Wiring 1
EXPOSED ELECTRICAL WIRES
ELECTRICAL PANEL

Exposed electrical wires were present in panel. A qualified contractor should evaluate and repair or replace as necessary.

Electrical Contractor
29 – Water Heating Equipment – Units A,B
29.5.1 – Combustion Air Supply
NOT PRESENT
WATER HEATER

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

Qualified Professional
29.6.1 – Gas Supply Shut-Off Valve
Gas Supply Shut-Off Valve 1
NO FLEX LINE
WATER HEATER

The gas supply lines for the water heater were not comprised of flexible lines in the case that the floor heaves or settles. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
29.7.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
MISSING – PIPE
WATER HEATER

The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
29.8.1 – Exterior Condition/Leakage
Exterior Condition/Leakage 1
RUSTED
WATER HEATER

The water heating equipment was rusted/corroded showing signs of previously leaking. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
29.11.1 – Operation & Response to Controls
NOT FUNCTIONING
WATER HEATER

The water heater did not respond to controls or the demand for hot water and was not operational. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
29.12.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE LOW
WATER HEATER

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
 
30 – Water Heating Equipment – Unit C
30.2.1 – Water Shut-Off & Pipe Connections
Water Shut-Off & Pipe Connections 1
CORRODED – PIPE FITTINGS
WATER HEATER

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Qualified Professional
30.5.1 – Combustion Air Supply
NOT PRESENT
WATER HEATER

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

Qualified Professional
30.6.1 – Gas Supply Shut-Off Valve
Gas Supply Shut-Off Valve 1
NO FLEX LINE
WATER HEATER

The gas supply lines for the water heater were not comprised of flexible lines in the case that the floor heaves or settles. The gas supply lines for the water heater were not comprised of flexible lines in the case that the floor heaves or settles. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
30.7.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
MISSING – PIPE
WATER HEATER

The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
31 – Water Heating Equipment Unit D
31.2.1 – Water Shut-Off & Pipe Connections
Water Shut-Off & Pipe Connections 1
CORRODED – PIPE FITTINGS
WATER HEATER

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Qualified Professional
31.5.1 – Combustion Air Supply
NOT PRESENT
WATER HEATER

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

Qualified Professional
31.6.1 – Gas Supply Shut-Off Valve
Gas Supply Shut-Off Valve 1
MISSING CAP
WATER HEATER

The water heater gas line was missing a cap and could be turned on inadvertently. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
31.7.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
OVER 6″ FROM FLOOR

The TPRV pipe did not conspicuously terminate within 6 inches of the floor. This may allow high pressure hot water to cause unnecessary damage. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
 
32 – Structural Basement – Unit C
32.2.1 – Basement Floor Structure
Basement Floor Structure 1
HEAVING & SETTLING OF CONCRETE FLOOR
BASEMENT

Indications of movement/settling of the concrete floor were present in the basement area. This may be a compromise the structural integrity of the foundation or structure of the house which only a qualified structural engineer could comment after further analysis.

Recommend a qualified structural engineer inspect further and provide a professional opinion related to this observation.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-400-8148.

Structural Engineer
32.3.1 – Foundation Wall
Foundation Wall 1
Foundation Wall 2
MINOR CRACKS/MOVEMENT
BASEMENT

There were several cracks as well as movement in the basement foundation wall. These cracks should be sealed to prevent moisture intrusion, and monitored for further movement. Further analysis by a licensed structural engineer is recommended. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-400-8148.

Structural Engineer
32.6.1 – 1st Floor Structure & Supports
1st Floor Structure & Supports 1
SUPPORTS NOT INSTALLED CURRENT STANDARDS
BASEMENT

The structural supports did not appear to be installed in accordance with current construction standards. Further analysis by a licensed structural engineer is recommended. Axium recommends our premier partner – Level Engineering.  They can be contacted at 720-400-8148.

Structural Engineer
32.6.2 – 1st Floor Structure & Supports
1st Floor Structure & Supports 2
IMPROPER NOTCH, HOLE, OR CUT
BASEMENT

The floor structure had cutting, notching and boring of framing members that may, present a structural or safety concern.

Recommend a qualified contractor evaluate and repair or replace as needed.

  • Notches in solid lumber joists, rafters and beams can not be greater than 1/6th of the member’s depth, must not be longer than 1/3rd of the member depth, and must not be located in the middle 1/3rd of the span.
  • Notches at the ends must not exceed 1/4th the member depth.
  • The tension side of members 4 inches or greater in thickness must not be notched, except at the ends.
  • The diameter of holes bored or cut into members must not exceed 1/3rd the member depth.
  • Holes must not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. If the member is notched, the hole must not be closer than 2 inches to the notch.
  • Any “scab” boards sistered in place around the notch require proper sizing and fastening
Qualified Professional
32.7.1 – Insulation
Insulation 1
NO INSULATION
BASEMENT

There is no insulation on the basement exterior walls or floor system. Heat loss can occur more on this property than one that is properly insulated. A qualified contractor should evaluate and repair or replace as as necessary.

Qualified Professional
32.9.1 – Electrical in Basement
Electrical in Basement 1
LOOSE WIRE END/SPLICE
BASEMENT

A loose wire end and/or splice was located. A qualified contractor should evaluate and repair or replace as necessary.

Electrical Contractor
32.9.2 – Electrical in Basement
Electrical in Basement 2
Electrical in Basement 3
Electrical in Basement 4
EXPOSED ELECTRICAL SPLICES
BASEMENT

Exposed electrical conductor splices need to be installed inside a junction box with cover plate. A qualified contractor should evaluate and repair or replace as necessary.

Electrical Contractor
33 – Structural Crawlspace – Unit C
33.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
NO BARRIER
CRAWLSPACE

No soil cover was installed at the time of the inspection. Soil covers help reduce humidity levels in crawlspaces by limiting moisture evaporation into the air from soil. Reducing humidity levels can help reduce the chances for mold growth and deterioration of structural components. A qualified contractor should evaluate and install a soil cover as necessary.

Qualified Professional
33.4.1 – Floor Structure & Supports
Floor Structure & Supports 1
WOOD ON OR NEAR SOIL
CRAWLSPACE

Wooden structural components were in contact with soil or in close proximity with soil.  This condition is prone to water penetration into the structural materials resulting in water damage. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
33.4.2 – Floor Structure & Supports
Floor Structure & Supports 2
LEANING/NOT LEVEL
CRAWLSPACE

Some supports in the crawlspace were leaning/not level and may not be providing the proper support. A qualified structural engineer should evaluate and repair or replace as as necessary.

Qualified Professional
33.4.3 – Floor Structure & Supports
Floor Structure & Supports 3
Floor Structure & Supports 4
SUPPORTS-NOT UP TO CURRENT STANDARDS
CRAWLSPACE

The structural supports did not appear to be installed in accordance with current construction standards. Further analysis by a licensed structural engineer is recommended. Axium recommends our premier partner – Level Engineering.  They can be contacted at 720-400-8148.

Qualified Professional
33.4.4 – Floor Structure & Supports
Floor Structure & Supports 5
MOISTURE DAMAGE
CRAWLSPACE

Signs of past moisture damage was present on the sub floor in the crawlspace area. A qualified contractor should evaluate and repair or replace as as necessary.

Qualified Professional
33.6.1 – Insulation
Insulation 1
INSULATION NEEDED
CRAWLSPACE

There is no insulation on the crawlspace exterior walls or floor system. Heat loss can occur more on this property than one that is properly insulated. A qualified contractor should evaluate and repair or replace as as necessary.

Qualified Professional