2 – Roof
2.4.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Gutter Contractor
2.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
CORRODED

One or more combustion appliance exhaust flue(s) exhibited heavy corrosion.  A qualified contractor should evaluate and repair/replace as necessary.

Qualified Professional
 
3 – Attic, Insulation & Ventilation
3.2.1 – Attic Structural Components
Attic Structural Components 1
RAFTER SPLIT
One or more rafter boards were split.  A qualified contractor should evaluate and repair or replace as necessary.
Carpentry Contractor
3.4.1 – Insulation in Attic
Insulation in Attic 1
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
 
4 – Exterior
4.2.1 – Walkways & Driveways
Walkways & Driveways 1
Walkways & Driveways 2
Walkways & Driveways 3
HEAVING AND/OR SETTLING

The driveway/walkway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Driveway Contractor
4.2.2 – Walkways & Driveways
Walkways & Driveways 4
NOT SEALED PROPERLY

A walkway was not properly sealed against a foundation wall and may allow excess moisture to enter. Recommend a qualified contractor and repair or replace as needed.

Qualified Professional
4.2.3 – Walkways & Driveways
Walkways & Driveways 5
IMPROPERLY SLOPED SURFACE

The driveway or walkway has a negative slope and drains towards the house. This condition is prone to water penetration into the house structure. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Driveway Contractor
4.2.4 – Walkways & Driveways
Walkways & Driveways 6
MAJOR CRACKING – DRIVEWAY

There were signs of indications of major cracking at the driveway. This condition could be a trip hazard. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Concrete Contractor
4.3.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

Qualified Professional
4.3.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
WOOD ROT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
4.4.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
ERODED GRADE

Grade has eroded or was poorly back-filled near foundation wall, patio, or stairway.

Recommend a qualified contractor evaluate and repair or replace as necessary.

Qualified Professional
4.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
MOISTURE DAMAGE

Components of the eaves, facia, and/or soffit was warped, swollen, or had peeling paint which are signs of water damage. The materials will eventually begin to rot if left untreated or cause has not been corrected.

A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
4.5.2 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 2
PEELING PAINT

The paint was peeling or cracking in one or more areas of the eaves.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Painting Contractor
4.6.1 – Exterior Doors
Exterior Doors 1
BROKEN/CRACKED GLASS

An entry door had a broken or cracked glass pane.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
4.6.2 – Exterior Doors
Exterior Doors 2
GAP AT DOOR

An exterior entry door had a gap at the bottom of the door.  A qualified contractor should evaluate and repair or replace as necessary.

Door Repair and Installation Contractor
4.9.1 – Windows
Windows 1
CRACKED – GLASS WINDOWPANE
A window had cracked glass or cracked windowpane.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Window Repair and Installation Contractor
4.10.1 – Window Wells
Window Wells 1
WINDOW WELLS MISSING COVER

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
4.15.1 – Exterior Foundation Wall
Exterior Foundation Wall 1
DETERIORATED CONCRETE

Visible exterior foundation walls appeared deteriorated in areas at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
 
5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls
Ceilings & Walls 1
ASBESTOS CEILING

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

Qualified Professional
5.2.2 – Ceilings & Walls
Ceilings & Walls 2
DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.2.3 – Ceilings & Walls
Ceilings & Walls 3
Ceilings & Walls 4
MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.2.4 – Ceilings & Walls
Ceilings & Walls 5
MINOR CRACKS-WALLS

Minor cracking was visible on the interior walls.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.2.5 – Ceilings & Walls

Ceilings & Walls 6

PAINT PEELING

The paint was peeling in areas.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.2.6 – Ceilings & Walls
Ceilings & Walls 7
SAGGING

The tiles on the ceiling were sagging.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.2.7 – Ceilings & Walls
Ceilings & Walls 8
SIGNS OF REPAIR-CEILINGS

The ceilings had signs of previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.3.1 – Floors
Floors 1
ASBESTOS TILES

The property had tiles that may contain asbestos. A qualified contractor should evaluate and repair or replace as necessary. Flooring, including sheet vinyl, vinyl or asphalt floor tiles and any associated paper-like backing, mastic, adhesive or glue, may contain asbestos. In the past, asbestos fibers were added during the production of flooring materials to strengthen the flooring and to increase its durability. Flooring that contains asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken flooring to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

Qualified Professional
5.3.2 – Floors
Floors 2
CARPET LOOSE

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.3.3 – Floors
Floors 3
FLOOR DAMAGED

The floor covering was damaged in several areas at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised.

Qualified Professional
5.4.1 – Doors
Doors 1
DAMAGED – DOOR

The door was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.4.2 – Doors
Doors 2
MISSING – DOOR

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.4.3 – Doors
Doors 3
WON’T CLOSE

The door would not close using reasonable force. A qualified contractor should evaluate, then repair or replace as advised.

Qualified Professional
5.5.1 – Windows
Windows 1
NEARING THE END OF LIFE EXPECTANCY

The windows in the building appeared to be original and were either at or near their serviceable lifespan. Recommend further evaluation by a qualified contractor and budgeting for potential future replacement.

Qualified Professional
5.5.2 – Windows
Windows 2
GLASS BROKEN/CRACKED

The window had a cracked or broken glass pane.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.5.3 – Windows

Windows 3

WON’T OPEN

The window could not be opened at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.6.1 – Electrical Outlets
Electrical Outlets 1
NOT GROUNDED – OUTLET

One or more electrical outlets were not grounded. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.6.2 – Electrical Outlets
Electrical Outlets 2
Electrical Outlets 3
Electrical Outlets 4
TWO PRONG OUTLET

The inspector observed many two-prong outlets throughout the property. These are outdated outlets that should be upgraded to three-prong outlets with proper grounds. A qualified contractor should evaluate then repair or replace as advised.

Qualified Professional
5.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
Electrical Fixtures & Switches 2
NOT WORKING

One or more light fixtures/bulbs were not working at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
5.8.1 – Stairways & Railings
Stairways & Railings 1
NO RETURN AT ENDS

At the interior stairs, the handrail had a railing end that did not return to the wall or post.  A fall could occur if something (purse, backpack etc.) caught the end of the railing when descending. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.9.1 – Smoke & CO Detectors
SMOKE DETECTOR MISSING

The smoke detector was missing. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

Qualified Professional
5.10.1 – Installed Heat Source
Installed Heat Source 1
NO HEAT SOURCE
BASEMENT

There was no heat source installed in the basement. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
5.11.1 – Bar Sink
LEAK FAUCET
The sink faucet was leaking at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised.
Qualified Professional
 
6 – Bathroom
6.3.1 – Electrical Outlets
Electrical Outlets 1
TWO PRONG OUTLET

The inspector observed many two-prong outlets throughout the property. These are outdated outlets that should be upgraded to three-prong outlets with proper grounds. A qualified contractor should evaluate then repair or replace as advised.

Qualified Professional
6.4.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
6.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
6.6.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
MISSING – SINK DRAIN STOPPER

The sink drain stop was missing, damaged or did not operate properly.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
6.9.1 – Toilets
Toilets 1
FLUSH WEAK
The toilet flush very slowly. This may indicate the presence of a clog or obstruction in the toilet or sewer drain. A qualified contractor should evaluate and repair or replace as necessary.
Qualified Professional
 
7 – Bathroom 2
7.3.1 – Electrical Outlets
Electrical Outlets 1
TWO PRONG OUTLET

The inspector observed many two-prong outlets throughout the property. These are outdated outlets that should be upgraded to three-prong outlets with proper grounds. A qualified contractor should evaluate then repair or replace as advised.

Qualified Professional
7.4.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB

One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

Qualified Professional
7.6.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
FLEX

Flexible drain lines can clog, leak or fail.  A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
7.6.2 – Drain Waste and Vent System
Drain Waste and Vent System 2
MISSING – SINK DRAIN STOPPER
The sink drain stop was missing, damaged or did not operate properly.  A qualified contractor should evaluate and repair or replace as necessary.
Qualified Professional
7.9.1 – Toilets
Toilets 1
LOOSE AT THE FLOOR

The toilet was loose at the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. Loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8 – Heating
8.1.1 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY
Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate and repair or replace as necessary.
Qualified Professional
8.2.1 – Exhaust Flue
Exhaust Flue 1
B-VENT CLEARANCE UNDER 1″
The B-Vent (double wall) exhaust flue had improper clearance from combustible materials. This type of vent requires 1-inch minimum clearance. This condition is a potential fire hazard. A qualified contractor should evaluate and repair or replace as necessary.
Qualified Professional
8.7.1 – Condensate
Condensate 1
SECONDARY

The secondary drain line was capped, missing or not routed to a drain. If the primary drain line becomes blocked, this condition could cause condensation to not drain properly and possibly damage the unit. The inspector recommends installing a secondary drain or installing an over flow protection device. A qualified contractor should evaluate then repair or replace as advised.

Qualified Professional
8.8.1 – Ductwork
Ductwork 1
ASBESTOS TAPE

The property had duct insulation or tape that may contain asbestos. Materials, including sheet vinyl, vinyl or asphalt floor tiles and any associated paper-like backing, mastic, adhesive or glue, may contain asbestos. In the past, asbestos fibers were added during the production of flooring materials to strengthen the flooring and to increase its durability. Flooring that contains asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken flooring to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
8.9.1 – Air Filter
Air Filter 1
VERY DIRTY

The HVAC system air filter was very dirty or clogged. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict air flow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing filter, as well as cleaning, servicing and evaluating of the HVAC system by a qualified HVAC professional and repair or replace as necessary.

HVAC Professional
8.12.1 – Heating System Ignition & Operation
Heating System Ignition & Operation 1
DIRTY
The heating system did fire and appeared to be in serviceable condition at the time of the inspection. However, the interior of the cabinet was dirty. Cleaning, servicing and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.
HVAC Professional
9 – Heating – Other
9.2.1 – Thermostat & Heat Source
Thermostat & Heat Source 1
NOT OPERATIONAL

The electric baseboards did not respond to user operating controls and was considered not operational at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised.

Qualified Professional
10 – Cooling
10.2.1 – Cooling Equipment Information
Cooling Equipment Information 1
Cooling Equipment Information 2
COOLING SYSTEM INACCESSIBLE
The cooling system condenser cabinet was inaccessible. A qualified contractor should evaluate and repair/replace as necessary prior to your inspection objection deadline.
Qualified Professional
 
11 – Plumbing
11.1.1 – Main Water Shut-Off Valve
Main Water Shut-Off Valve 1
CORRODED – VALVE

The main water shutoff valve was corroded.

The valve is not and was not operated during the scope of a home  inspection.

Recommend a qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
11.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
GALVANIZED
The property contained galvanized steel water distribution pipes. These pipes are outdated and subject to corrosion which will eventually result in restricted flow and leakage and will need to be replaced. Water flow in the property was satisfactory at the time of the inspection.
Qualified Professional
11.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

Qualified Professional
 
12 – Water Heating Equipment
12.4.1 – Draft Diverter & Exhaust Flue
Draft Diverter & Exhaust Flue 1
B VENT CLEARANCE 1″

The gas-fired water heater has a B vent exhaust flue with improper clearance from combustible materials. This type of vent is double walled and requires 1-inch minimum clearance. This condition is a potential fire hazard. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

Qualified Professional
12.7.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
MISSING – PIPE

The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

Qualified Professional
 
13 – Electrical
13.2.1 – Distribution Panels
Distribution Panels 1
SCREWS MISSING – PANEL COVER
Screws / fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.
Qualified Professional
13.5.1 – Electrical Circuit Breakers
Electrical Circuit Breakers 1
DIFFERENT BRANDS

Some or all circuit breakers were a brand different from the main panel brand. Circuit breakers made by different manufacturers vary in design, therefore panel manufacturers require their own manufactured breakers to be used. Select brands are interchangeable, and there are some “semi” universal breaker types or panel types.

Using incompatible breakers in the panel of another manufacturer may result in poor connections which can create a potential fire or shock/electrocution hazard. A qualified contractor should evaluate and repair or replace as necessary.

Electrical Contractor
 
14 – Structural Basement
14.4.1 – Basement Interior Wall Structure
Basement Interior Wall Structure 1
BASEMENT WALLS NOT FLOATING

Basement walls were not constructed using a method which will allow for soil movement. This method is usually termed “floating” the walls and involves leaving a gap at the bottom of the wall so that vertical movement (heaving) of the concrete slab basement floor will not be transmitted to the rest of the property structure. Colorado has areas with expansive soils. Expansive soils are soils which increase to many times their original volume in response to increases in soil moisture content, creating forces which can easily damage property structural components such as foundations, floor slabs, flat work and interior and exterior wall coverings. Consider consulting with a qualified contractor before the expiration of your Inspection Objection Deadline to discuss options and costs for correction an/ or stabilization.

Qualified Professional
14.5.1 – Moisture Intrusion
Moisture Intrusion 1
EFFLORESCENCE

Efflorescence (white powdery substance) on the wall indicates moisture is in contact with the concrete or masonry. This does not necessarily indicate that intrusion will occur. I recommend checking the gutters and the downspout drain lines for proper operation. Also, a water proofing paint could be applied to the interior side of the wall if necessary. Efflorescence is found on many properties without water intrusion occurring inside the property. But, it should alert you to the possibility that future steps may be needed. A qualified contractor should evaluate and repair as necessary.

Qualified Professional
14.9.1 – Electrical in Basement
Electrical in Basement 1
DEFECT – LIGHT FIXTURE

One or more light fixtures in basement were not properly installed/secured. A qualified contractor should evaluate, then repair or replace as advised.

Qualified Professional