Full Report

Summary

PDF

Summary Text (enter here)

2 – Attic, Insulation and Ventilation Edit Section
2.3.1 – Attic Moisture Intrusion
Rusty Nails

Rusty nails often signal excess condensation build-up due to poor ventilation. Recommend a qualified contractor evaluate further to repair or replace as needed. 

4 – Interior, Doors, Windows Edit Section
4.2.1 – Ceilings & Walls
Asbestos Ceiling
Throughout Property

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s. 

In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

4.4.1 – Doors
Strike Not Latching
Master Bedroom

The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

4.5.1 – Windows
Broken Seals
Bedrooms

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass was observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary. 

4.5.2 – Windows
Worn or Nearing the End of Life Expectancy

Windows installed in the home appeared to be worn or aged. This apparent condition can mean the windows are deteriorated or difficult to operate, and can also mean they are not consistent with current efficiency standards. They were possibly original and were either at or near their serviceable lifespan. Recommend further evaluation by a qualified contractor and budgeting for potential future replacement. 

4.5.3 – Windows

Stuck Shut
Bedrooms

The window had a sash that was unable to be opened without excessive force, possibly from being painted or nailed shut.  A qualified contractor should evaluate and repair or replace as necessary. 

4.5.4 – Windows
Water Penetration
Back Bedroom

Signs of water penetration was present at the window(s).  A qualified contractor should evaluate and repair or replace as necessary. 

4.7.1 – Electrical Fixtures & Switches
Missing – Bulb
Dining Room

The light fixture was missing one or more bulbs. A qualified contractor should evaluate and repair or replace as necessary. 

4.8.1 – Stairways & Railings
Spindle Spacing Over 4″

At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary. 

4.9.1 – Smoke & CO Detectors
CO Detector Missing

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper level. 

5 – Detached Garage Edit Section
5.4.1 – Ceiling & Walls in Garage
Defect – Wall

A defect at the wall was present in the detached garage. 

Recommend a qualified contractor evaluate and repair or replace as needed.

5.4.2 – Ceiling & Walls in Garage
Moisture Intrusion

Garage walls/ceilings showed signs of moisture intrusion. Recommend a qualified contractor evaluate and find source of moisture to prevent further damage and/or mold. 

5.5.1 – Floor
Improperly Sloped

The floor surface of the garage is not sloped properly away from the structure due to settlement. 

The area of floor used for parking of automobiles or other vehicles must be sloped. It should slope toward the vehicle door opening. The sloped surface will help the movement of liquids to a drain or toward the main vehicle doorway of the carport. 

5.6.1 – Vehicle Door
Not Sealed at Floor

The garage door was missing weather stripping or did not evenly seal at the floor. A qualified contractor should evaluate and make adjustments, repair, or replace as necessary.

5.7.1 – Door Opener
Reverse Sensors Too High

The photo-electric reverse sensors are installed too high from the garage floor surface. 

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

6 – Exterior – Condo/Townhome Edit Section
6.1.1 – Garage Door Exterior
Damaged – Panel(s)

The exterior of garage door has one or more damaged panels. A qualified contractor should inspect and repair as necessary and according to current standards.

6.3.1 – Electrical Fixtures
Not Working – Bulb
Back

A bulb at an exterior light fixture did not respond to the switch at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

6.4.1 – Electrical Outlets
No Exterior GFCI Protection

No Ground Fault Circuit Interrupter (GFCI) protection was provided for the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

6.4.2 – Electrical Outlets
Missing Weatherproof Covering

The exterior electrical outlet was missing a weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

6.4.3 – Electrical Outlets
Reverse Polarity

An exterior electrical outlet was wired incorrectly with “reverse polarity,” meaning the hot and neutral wires are reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created because there is still electricity running through the hot wire when the switch is turned off. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

6.5.1 – Exterior Faucets (Hose Bibs)
Loose in Wall

One or more exterior faucet was loose in the wall. The faucet should be securely fastened to the wall using appropriate screws depending on material at location of the faucet. Recommend a qualified contractor evaluate and repair or replace as needed.

6.5.2 – Exterior Faucets (Hose Bibs)
Significant Leak – Knob

The outside water faucet had a significant leak from the knob/handle when the water pressure gauge was attached. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

6.7.1 – Roof Drainage – Downspouts & Extensions
Extensions Not Positioned Properly

One or more downspout extensions were not properly positioned. Extensions should not be in the upright position or should not route run-off too close to the foundation. 

Recommend a qualified contractor evaluate and repair or replace as necessary.

 

These downspouts may account for the moisture intrusion in the crawlspace.

7 – Kitchen Edit Section
7.5.1 – Cabinets & Counters
Damaged – Cabinet Floor

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years. 

A qualified contractor should evaluate and repair or replace as necessary.

7.13.1 – Dishwasher
No High Loop

The dishwasher drain line came out from a low location and did not discharge into a higher drain pipe. Dishwasher drain lines require a “high loop” in the line in order to drain properly. A “high loop” may have been hidden behind the appliance itself. The high loop in the drain hose is to keep water from settling in the hose to prevent any odors from backing up into the dishwasher. Food or debris may become stuck in the line and smell or mold if not corrected. Recommend a qualified contractor evaluate and repair or replace as needed. 

8 – Laundry Edit Section
8.2.1 – Doors
Rubs Frame
Laundry Area

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly. 

A qualified contractor should evaluate and repair or replace as necessary. 

8.4.1 – Exhaust Fan
Fan Needed

There was no ventilation (exhaust fan or openable window) In the laundry area. Normally an exhaust fan or an openable window is needed for proper ventilation.  A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Electrical Outlets
GFCI Protection Not Present

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

8.10.1 – 220 Volt Dryer Outlet
Not Working

The 220-volt dryer electrical outlet was damaged not working.  A qualified contractor should evaluate and repair or replace as necessary.

8.11.1 – Dryer Vent Piping
Plastic Vent

A dyer vent connection was installed in the laundry area. The dryer was vented using a flexible plastic vent which is not approved by the Underwriter’s Laboratory (UL). Flexible plastic dryer vent is more likely to accumulate lint than a smooth metal vent creating a potential fire hazard. Excessive lint accumulation can increase drying time and shorten the dryers lifespan. The inspector recommends replacing the plastic vent with a properly installed UL approved dryer vent. A qualified contractor should evaluate and repair or replace as necessary.

8.11.2 – Dryer Vent Piping
Excessive Lint Build-Up

Excessive lint was built up behind the dryer area, and in parts of laundry area. The dryer vent connection may have become disconnected and should be reconnected to properly route the dryer exhaust to the exterior. Failure to reconnect the vent may result in unsatisfactory conditions from excessive humidity and lint accumulation in the home. Excessively high humidity can damage home materials or components and may encourage the growth of microbes such as mold. A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom Edit Section
9.2.1 – Doors
Damaged – Door
Master Bathroom

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary. 

9.4.1 – Ceilings & Walls
Paint Peeling
Master Bathroom

The paint was peeling in areas.  A qualified contractor should evaluate and repair or replace as necessary.

9.6.1 – Windows
Skylight painted over

The skylight in the master bathroom was painted over at the time of the inspection.

9.10.1 – Drain Waste and Vent System
Not Working – Sink Stopper

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

10 – Bathroom 2 Edit Section
10.9.1 – Cabinets & Counters
Damaged – Cabinet Floor

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years. 

A qualified contractor should evaluate and repair or replace as necessary.

10.10.1 – Drain Waste and Vent System
Not Working – Sink Stopper
2nd Floor Hallway Bathroom

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

10.13.1 – Toilets
Missing toilet paper holder

Missing a toilet paper holder At the time of inspection. Recommend a qualified contractor evaluate and install as needed.

11 – Bathroom 3 Edit Section
11.2.1 – Doors
Not Operate Smoothly
1st Floor 1/2 Bathroom

The door did not operate smoothly.  A qualified contractor should evaluate and repair or replace as necessary. 

11.2.2 – Doors
Damaged Hardware

Hardware was damaged on  an interior bathroom door at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed. 

11.7.1 – Electrical Outlets
Not Working
1st Floor Bathroom

An electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary.

11.7.2 – Electrical Outlets
Will Not Reset
1st Floor Bathroom

A GFCI outlet was defective and will not reset once tripped. A qualified contractor should evaluate and repair or replace as necessary.

11.10.1 – Drain Waste and Vent System
Leaking

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

13 – Electrical Edit Section
13.2.1 – Distribution Panels
FPE Federal Pacific Panel

The main electrical distribution panel is a Federal Pacific Electric (FPE) panel. These panels have a reputation for being problematic and further evaluation by a qualified electrician is recommended. FPE panel breakers are known to fail to trip at a much higher rate than standard panels. When a breaker fails to trip, the breaker and other components, including wires, may overheat and melt. The panel itself could overheat and catch fire. 

Due to safety concerns, no further evaluation was conducted on this panel.  A qualified contractor should evaluate and replace as necessary. 

14 – Water Heating Equipment Edit Section
14.3.1 – Pipe Connections
Corroded – Pipe Fittings

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

14.13.1 – Water Temperature
Water Temperature Low

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

15 – Heating Edit Section
15.1.1 – Heating System Information
Servicing Recommended

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional. 

15.1.2 – Heating System Information
Not Accessible
15.5.1 – Gas Supply Shut-Off Valve
No Gas Shut-Off Valve

There was no gas shutoff valve installed at the heating system equipment. Safe building practices require a gas shutoff valve be installed at every gas-burning appliance. A qualified contractor should evaluate and repair or replace as necessary.

15.6.1 – Cabinet
Corroded, Rusted

The heating system cabinet was corroded, rusted or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

16 – Cooling Edit Section
16.1.1 – Cooling System Information
Beyond Typical Life Expectancy

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

16.1.2 – Cooling System Information
Label Worn Out

The manufacturing label on the system was worn out and illegible. This is an indication of old age, or prolonged exposure to harsh elements. Recommend a qualified contractor further evaluate and repair or replace.

16.2.1 – AC Refrigerant Lines
Damaged Insulation

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

16.3.1 – AC Compressor
Unit is Not Level

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16.3.2 – AC Compressor
Coil Fins Damaged

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

16.4.1 – AC Service Disconnect
Panel Housing Loose

The electrical service disconnect for the air conditioning condenser had a loose panel housing and was not properly secured to the wall. A qualified contractor should evaluate and repair/replace as necessary.

17 – Structural Crawlspace Edit Section
17.2.1 – Soil Vapor Barrier
No Barrier

No soil cover was installed at the time of the inspection. Soil covers help reduce humidity levels in crawlspaces by limiting moisture evaporation into the air from soil. Reducing humidity levels can help reduce the chances for mold growth and deterioration of structural components. A qualified contractor should evaluate and install a soil cover as necessary.

17.3.1 – Moisture Intrusion
Active Leak

The inspector observed signs of a possible active leak in the crawlspace.

17.3.2 – Moisture Intrusion
+ 1 more
Excessive Ground Moisture

Areas of the crawlspace were visibly wet or soft/squishy under the vapor barrier. The ground showed signs of moisture intrusion. A qualified contractor should evaluate and repair or replace as necessary.

17.3.3 – Moisture Intrusion
Standing water

There is a large puddle of standing water directly in front of the furnace. A qualified contractor should investigate and repair or replace as necessary.

17.8.1 – Electrical in Crawlspace
Loose Wire End/Splice

A loose wire end and/or splice was located. A qualified contractor should evaluate and repair or replace as necessary.

17.8.2 – Electrical in Crawlspace
Electrical + water

There is standing water in the crawlspace with an electrical wire running right through it. A qualified plumber and electrician should investigate and repair or replace as necessary.

17.10.1 – Wasp nest
Wasp nest

There is a large wasp nest in the crawl space

19 – Sewer Scope Edit Section
19.4.1 – Sewer Line Condition
Belly

There is a low point in the drain line which will promote clogging.  We recommend further review and repair as needed.

19.4.2 – Sewer Line Condition
Offset

There is an offset in the drain line where two pipes are not properly connected and there is a “lip” that can cause clogging or leaking.  We recommend further review and repair as needed.