 2 – Roof EDIT SECTION
2.2.1 – Roof Covering
NOT SEALED – SHINGLES

One or more shingle strips were not completely sealed at the edges. Unsealed shingles in high wind conditions may cause a blowup of some shingles or even blow off a section. Recommend a qualified contractor evaluate and repair or replace as needed. 

 EDIT

2.2.2 – Roof Covering
OLDER ON ONE SIDE

The roof covering material appears to be older on one side (or in areas) of the structure.  This can be a sign of  insufficient attic ventilation. 

 Recommend a qualified contractor evaluate and repair or replace as necessary.

2.6.1 – Flue Gas Vent Pipes
DENTED OR DAMAGED – CAP

Flue Pipe cap is excessively dented or damaged. Recommend a qualified contractor evaluate and repair or replace as necessary.

2.7.1 – Masonry Chimney
DAMAGE – MORTAR CROWN

The mortar crown was cracked or deteriorated at the time of inspection. 

If the crown on top of the chimney is not properly sealed or is extensively cracked, defective, spalled, or displays rust stains, it should be replaced. Sheet metal caps/crowns with minor rust or corrosion should be repaired, but if rust or corrosion is extensive, replacement is recommended. 

2.7.2 – Masonry Chimney
MISSING – RAIN CAP

The chimney was missing a rain cap and/or spark arrestor. 

The rain cap covers the top opening of the chimney flue liner and is usually combined with a spark arrestor.

Spark arrestors are to prevent floating embers from a fire (particularly one burning wood) setting light to a flammable roofing surface or falling onto combustible material on the ground. Such a spark arrestor typically consists of a double layer of metal mesh, which catches the ember and allows the flue gas to escape. Spark arrestors also help prevent animals from entering the chimney.

Recommend a qualified contractor evaluate and install the required components.

2.8.1 – Roof Drainage Systems
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. 

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation and Ventilation EDIT SECTION
3.1.1 – Attic Access
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

3.2.1 – Attic Structural Components
ROOF DECKING DAMAGED/ALTERED

The roof decking had been damaged or altered. This can affect the overall structural integrity of the roof, and cause the roof to sag or fail in that area. 

Trusses are specifically engineered and designed to support the roof and loads placed on it, such as snow. The individual components of a truss — webs, connectors, gusset plates, straps, clips, and fasteners — and all trusses in a roof are designed to perform together as a system. Recommend further evaluation by a licensed roofing contractor and/or structural engineer to determine the effect of the damage or alterations, and options for any necessary repairs.

3.4.1 – Insulation in Attic
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards. 

Recommend a qualified contractor evaluate and repair or replace as needed.

3.5.1 – Ventilation in Attic
VENTILATION INADEQUATE

Ventilation may have been insufficient at the time of the inspection. 

Inadequate attic ventilation can cause the attic to overheat, causing heat damage to the roof covering, which results in a decreased life expectancy. Adequate ventilation of the attic will actually help prolong the life expectancy of the roof covering and help stabilize interior temperatures when heating and cooling is in use. 

Recommend a qualified contractor evaluate to ensure all attic ventilation is unobstructed and fully functional and/or install additional ventilation as needed.

3.6.1 – Electrical Wiring In Attic
EXPOSED ELECTRICAL SPLICES

Exposed electrical conductor splices need to be installed inside a junction box with cover plate. A qualified contractor should evaluate and repair or replace as necessary.

3.7.1 – Exhaust System Vents
BATHROOM FAN EXHAUSTS INTO ATTIC

Bathroom vent duct terminated in the attic and did not vent to the exterior of property. 

3.7.2 – Exhaust System Vents
CORRODED – FLUE PIPES

Flue pipe was corroded at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

 4 – Exterior EDIT SECTION
4.2.1 – Driveways
CRACKING – MODERATE

The concrete driveway was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

4.4.1 – Wall-Covering, Flashing & Trim
DAMAGED – SIDING

The siding and/or trim was damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.2 – Wall-Covering, Flashing & Trim
PEELING PAINT

Peeling paint was present in areas. 

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary. 

4.4.4 – Wall-Covering, Flashing & Trim
TUCK POINTING NEEDED

A common maintenance task for brick masonry is the repair of mortar joints. The longevity of mortar joints will vary with the exposure conditions and the mortar materials used, but a life span of more than 25 years is typical. The longevity of brick, however, may well exceed 100 years. Consequently, occasional repair of the mortar joints is expected over the life of the brick masonry. It is our observation that the most common reason for repointing brick masonry is to improve water penetration resistance. Repointing deteriorated mortar joints is one of the most effective and permanent ways of decreasing water entry into brickwork. This is because the most common means of water entry into a brick masonry wall is through de-bonded, cracked or deteriorated mortar joints. A qualified contractor should evaluate and repair all areas as necessary.

4.6.1 – Exterior Doors

MISSING – WEATHER STRIPPING

The door was missing some or all weather stripping at the time of the inspection.

4.10.1 – Window Wells
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Walkways
CRACK AT STEP(S)

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.2 – Walkways
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.3 – Walkways
TRIP HAZARD – WALKWAY(S)

A trip hazard was present on the walkway(s) in areas.  This condition is a safety concern. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
DEFECT – FENCE

The fence is damaged or missing pieces.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.2 – Vegetation, Grading & Drainage
LARGE TREES FOUNDATION

Consideration should be given to trimming or even removing large tree(s) located close to the structure. We suggest consultation with a tree specialist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.14.1 – Exterior Faucets (Hose Bibs)
LOOSE IN WALL
FRONT

One or more exterior faucet was loose in the wall. The faucet should be securely fastened to the wall using appropriate screws depending on the material at the location of the faucet. Recommend a qualified contractor evaluate and repair or replace as needed.

4.14.2 – Exterior Faucets (Hose Bibs)
LEAKS AT ANTI-SIPHON
BACK

The exterior hose bib dripped from the anti-siphon when operated.

4.16.1 – Gas Meter, Gas Shut-Off
MINOR RUST

Pipes had minor surface rust at the gas meter. Monitoring and contacting a qualified professional to further evaluate for repairs is recommended

4.17.1 – Exterior Foundation Wall
CRACKS – AT CORNER(S)

The exterior foundation wall had cracks at the corner. A qualified contractor should evaluate and repair or replace as necessary.  Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

4.17.2 – Exterior Foundation Wall
CRACK – VERTICAL

The foundation had vertical cracks in areas. A qualified contractor should evaluate and repair as necessary before your inspection objection deadline.

4.21.1 – Roof Drainage – Downspouts & Extensions
MISSING – EXTENSIONS

Downspout(s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 5 – Interior, Doors, Windows EDIT SECTION
5.3.1 – Floors
FLOOR SQUEAKS

The floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary. 

5.4.1 – Doors
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary. 

5.4.2 – Doors
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly. 

A qualified contractor should evaluate and repair or replace as necessary. 

5.4.3 – Doors
RUBS FLOOR
BASEMENT RIGHT BEDROOM

An interior door rubs on the flooring when opening or closing. Recommend a qualified contractor evaluate and repair or replace as needed.

5.4.4 – Doors
DOOR WOULDN’T CLOSE
1ST FLOOR CLOSET

The door would not close at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary. 

5.5.1 – Windows
GLASS BROKEN/CRACKED

The window had a cracked or broken glass pane.  A qualified contractor should evaluate and repair or replace as necessary. 

5.5.2 – Windows
WORN OR NEARING THE END OF LIFE EXPECTANCY

Windows installed in the home appeared to be worn or aged. This apparent condition can mean the windows are deteriorated or difficult to operate, and can also mean they are not consistent with current efficiency standards. They were possibly original and were either at or near their serviceable lifespan. Recommend further evaluation by a qualified contractor and budgeting for potential future replacement. 

5.5.3 – Windows
NO EGRESS

At the time of the inspection, the property did not have emergency escape and rescue openings which met generally-accepted current standards. Egress opening requirements:

For safety reasons, all sleeping room and basements greater than 200 square feet and new properties should meet the generally-accepted current standards for emergency escape and rescue openings, which include the following requirements:

1. Sill height shall not exceed 44 inches above the floor.

2. Minimum net clear opening shall be 5.7 square feet; exception – grade level windows

may have a minimum clear opening of 5 square feet.

3. Minimum net clear opening height shall be 24 inches.

4. Minimum net clear opening width shall be 20 inches.

 

 

5.6.1 – Electrical Outlets
NOT GROUNDED – HOUSE

Although the 3-prong outlets installed in this property typically indicate a property with grounded branch wiring, this property had no grounding system installed to protect devices such as switches and electrical outlets. Although this condition may have been commonly considered safe or acceptable at the time the property was originally constructed, as general knowledge of safe building practices has improved with the passage of time, building standards have changed to reflect current understanding. A qualified contractor should evaluate and repair or replace as necessary.

5.7.1 – Electrical Fixtures & Switches
NOT WORKING – BULB(S)

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed. 

5.8.1 – Stairways & Railings
NO RETURN AT ENDS

At the interior stairs, the handrail had a railing end that did not return to the wall or post.  A fall could occur if something (purse, backpack etc.) caught the end of the railing when descending. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary. 

5.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
BASEMENT

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper level. 

5.11.1 – Fireplace Wood-Burning
CLEANING NEEDED

The visible areas of the firebox and chimney flue were dirty at the time of the inspection. Most of the chimney flue was inaccessible and was not inspected. Dirty flues are potential fire hazards and should be cleaned by a professional. Recommend having the chimney evaluated by a C.S.I. (Chimney Safety Institute) -qualified chimney sweep. 

5.11.2 – Fireplace Wood-Burning
DAMAGE TO FIREPLACE INTERIOR CHAMBER

The fireplace had damage to the interior chamber. A qualified contractor should evaluate and repair or replace as necessary.

 6 – Kitchen EDIT SECTION
6.2.1 – Doors
MISSING – DOOR

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary. 

6.4.1 – Floors
FLOOR SQUEAKS

The floor squeaks.  A qualified contractor should evaluate and repair or replace as necessary. 

6.5.1 – Cabinets & Counters
CAULKING – NEEDS TOUCH UPS

Caulking at the kitchen counter/backsplash area was poor installation, or had areas in poor condition and needs touch-up. Recommend a qualified contractor evaluate and repair or replace as needed.

6.6.1 – Electrical Outlets
NO GFCI PROTECTION

No ground fault circuit interrupter (GFCI) protection was provided for kitchen electrical outlets. Although GFCI protection of kitchen circuits may not have been required at the time in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing kitchen electrical circuits to provide GFCI protection. This can be achieved by: 

 

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary. 

6.6.2 – Electrical Outlets
2 PRONG OUTLET

The inspector observed many two-prong outlets throughout the property. These are outdated outlets that should be upgraded to three-prong outlets with proper grounds. A qualified contractor should evaluate then repair or replace as advised.

6.12.1 – Food Waste Disposer
MISSING WIRING CLAMP

The food waste disposer was missing the wiring connector (clamp and bushing).  A qualified contractor should evaluate and repair or replace as necessary. 

6.14.1 – Range/Oven/Cooktop
NOT IGNITING – BURNER

A cook top burner was not igniting at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

6.15.1 – Range Hood
VENTS IN TO CABINET

The microwave vent hood vents in to the cabinet space between the top of the microwave and the cabinet above it. The microwave needs to be removed and the fan rotated forward to vent out of the top front vent on the microwave.  A qualified contractor should evaluate and repair or replace as necessary. 

 7 – Laundry EDIT SECTION
7.7.1 – Windows
WORN OR NEARING THE END OF LIFE EXPECTANCY

Windows installed in the home appeared to be worn or aged. This apparent condition can mean the windows are deteriorated or difficult to operate, and can also mean they are not consistent with current efficiency standards. They were possibly original and were either at or near their serviceable lifespan. Recommend further evaluation by a qualified contractor and budgeting for potential future replacement. 

7.8.1 – Floors
FLOOR NOT SLOPED TOWARD DRAIN
LAUNDRY AREA

The floor was not sloped toward the drain which allows water to pool and possibly seep through the floor.  A qualified contractor should evaluate and repair or replace as necessary. 

7.9.1 – Electrical Outlets
GFCI PROTECTION NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

7.9.2 – Electrical Outlets

OUTLET NOT GROUNDED

An electrical outlet was not grounded. A qualified contractor should evaluate and repair or replace as necessary.

7.9.3 – Electrical Outlets
FACEPLATE MISSING

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

7.12.1 – Gas Supply Shut-Off Valve
NO CAP
 8 – Bathroom EDIT SECTION
8.2.1 – Doors
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary. 

8.15.1 – Fixture Valve Installation And Temperature

WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range. 

Recommend a qualified contractor evaluate and repair or replace as necessary.

8.15.2 – Fixture Valve Installation And Temperature
HOT SIDE NOT FUNCTIONAL
1ST FLOOR BATHROOM
 9 – Bathroom 2 EDIT SECTION
9.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation. 

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.  

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.  

A qualified contractor should evaluate and repair or replace as necessary.

9.6.1 – Windows
NOT FUNCTIONAL

The window was not considered a functional window.  A qualified contractor should evaluate and repair or replace as necessary. 

9.7.1 – Electrical Outlets
NO GFCI PROTECTION

No ground fault circuit interrupter (GFCI) protection was provided for the bathroom electrical outlets. Although GFCI protection of bathroom circuits may not have been required at the time of in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing bathroom electrical circuits to provide GFCI protection. This can be achieved by: 

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary. 

9.7.2 – Electrical Outlets
NOT GROUNDED

An electrical outlet was not grounded. A qualified contractor should evaluate and repair or replace as necessary.

9.9.1 – Cabinets & Counters

CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System

FLEX PIPE

Flexible drain lines can clog, leak or fail. Flex lines design includes multiple folds in which moisture may become trapped and mold may grow.  A qualified contractor should evaluate and repair or replace as necessary.

9.14.1 – Tub, Shower Area

CAULK – NEEDS TOUCH-UPS

Some caulking in the tub shower area was loose, old, or poorly done. Recommend a qualified contractor evaluate and re-caulk as needed. 

 11 – Electrical EDIT SECTION
11.2.1 – Distribution Panels
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too. 

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

11.5.1 – Electrical Circuit Breakers
DIFFERENT BRANDS

Some or all circuit breakers were a brand different from the main panel brand. Circuit breakers made by different manufacturers vary in design, therefore panel manufacturers require their own manufactured breakers to be used. Select brands are interchangeable, and there are some “semi” universal breaker types or panel types.

Using incompatible breakers in the panel of another manufacturer may result in poor connections which can create a potential fire or shock/electrocution hazard. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Water Heating Equipment EDIT SECTION
12.2.1 – Water Shut-Off
NOT PRESENT

There was no shut off valve installed on the water heater supply line. This means to replace the water heater the water would need to be turned off to the whole house. A qualified contractor should evaluate and repair or replace as necessary. 

12.5.1 – Draft Diverter & Exhaust Flue
DRAFT DIVERTER NOT ALIGNED/SECURED

The draft diverter of the gas-fired water heater was not properly aligned/secured. A qualified contractor should evaluate and repair as necessary.

12.8.1 – Temperature & Pressure Relief Valve
OVER 6″ FROM FLOOR

The TPRV pipe did not conspicuously terminate within 6 inches of the floor. This may allow high pressure hot water to cause unnecessary damage. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Heating EDIT SECTION
13.9.1 – Air Filter
DIRTY

The HVAC system air filter was dirty. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

 14 – Cooling EDIT SECTION
14.3.1 – AC Compressor
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

14.4.1 – AC Service Disconnect
SERVICE DISCONNECT NOT PRESENT

The electrical service disconnect for the air conditioning condenser was not present. A disconnect is required is required unless the condenser is within 50 feet of and within line of sight of the main electrical panel.  A qualified contractor should evaluate and repair/replace as necessary.

 15 – Cooling – Evaporative Cooler EDIT SECTION
15.2.1 – Cabinet, Reservoir, Drain Line
CORROSION

The reservoir appears to be corroded or rusted in areas. Recommend a qualified contractor evaluate and repair or replace as necessary.

15.3.1 – Evaporative Pads, Filters
EVAPORATIVE PADS – NEED REPLACEMENT

Recommend replacing the evaporative cooling pads on the swamp cooler and cleaning the reservoir. 

 16 – Structural Basement EDIT SECTION
16.2.1 – Basement Floor
CRACKED – COMMON

The concrete floor in the basement was cracked in areas. These cracks appear to be common cracks indicating regular settlement or heaving, but not necessarily structural problems. Recommend a qualified contractor to evaluate to make further recommendations and repair as necessary.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

16.5.1 – Moisture Intrusion
EFFLORESCENCE

Efflorescence (white powdery substance) on the wall indicates moisture is in contact with the concrete or masonry. This does not necessarily indicate that intrusion will occur. I recommend checking the gutters and the downspout drain lines for proper operation. Also, a water proofing paint could be applied to the interior side of the wall if necessary. Efflorescence is found on many properties without water intrusion occurring inside the property. But, it should alert you to the possibility that future steps may be needed. A qualified contractor should evaluate and repair as necessary.