2 – Roof EDIT SECTION
2.2.1 – Roof Covering
DEGRANULATED

Some of the shingles appear to be de-granulated in areas. Recommend a qualified contractor to evaluate and repair or replace as necessary.

2.2.2 – Roof Covering
HAIL/WIND/FOOT DAMAGE

The roof covering had minor damage from hail, wind, and/or foot traffic.  A qualified contractor should evaluate and repair or replace as necessary.

2.4.1 – Flashing
WALL FLASHING EXPOSED NAILS
BACK

Wall flashing has exposed nails. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

2.4.2 – Flashing
WALL FLASHING LOOSE

Wall flashing was loose. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

2.9.1 – Roof Drainage Systems
CORROSION – MODERATE

Gutters had moderate general corrosion visible. Corrosion is generally a sign of poor sloping or drainage, and continued corrosion will eventually result in leaking gutters.

This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.9.2 – Roof Drainage Systems
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation, and Ventilation EDIT SECTION
3.1.1 – Attic Access
ATTIC HATCH

The attic was located in the garage, however, it is not fire-rated material.

3.4.1 – Insulation in Attic
PAPER FACING THE  WRONG WAY

The insulation was improperly installed with a paper backing/vapor barrier facing the wrong way. This condition can trap moisture and create condensation, which may bring along more significant hazards such as accelerated wood rot, or mold.

Recommend a qualified contractor to evaluate and repair or replace as needed.

 4 – Attic, Insulation, and Ventilation 2 EDIT SECTION
4.5.1 – Ventilation in Attic
VENTILATION INADEQUATE

Ventilation may have been insufficient at the time of the inspection.

Inadequate attic ventilation can cause the attic to overheat, causing heat damage to the roof covering, which results in a decreased life expectancy. Adequate ventilation of the attic will actually help prolong the life expectancy of the roof covering and help stabilize interior temperatures when heating and cooling is in use.

Recommend a qualified contractor evaluate to ensure all attic ventilation is unobstructed and fully functional and/or install additional ventilation as needed.

 5 – Exterior EDIT SECTION
5.2.1 – Driveways
CRACKING – MODERATE

The concrete driveway was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

5.2.2 – Driveways
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.4.1 – Wall-Covering, Flashing & Trim
WOOD ROT
FRONT RIGHT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor to evaluate and repair or replace as necessary.

5.8.1 – Electrical Outlets
NO EXTERIOR GFCI PROTECTION

No Ground Fault Circuit Interrupter (GFCI) protection was provided for the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

5.8.2 – Electrical Outlets
MISSING WEATHERPROOF COVERING

The exterior electrical outlet was missing a weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.10.1 – Window Wells
WINDOW WELLS DEBRIS

Window wells had accumulated soil, leaves, and other debris which should be cleared to encourage proper drainage and minimize the retaining of moisture near the foundation and moisture intrusion and damage through the window area. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

5.11.1 – Walkways
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.11.2 – Walkways
TRIP HAZARD – WALKWAY(S)

A trip hazard was present on the walkway(s) in areas.  This condition is a safety concern. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.12.1 – Vegetation, Grading & Drainage
ERODED GRADE

Grade has eroded or was poorly back-filled near the foundation wall, patio, or stairway. This may allow moisture to pool near the structure, and this may allow significant cracking if not corrected.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

5.12.2 – Vegetation, Grading & Drainage
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

5.17.1 – Exterior Foundation Wall

CRACKS – AT CORNER(S)
THROUGHOUT PROPERTY

The exterior foundation wall had cracks at the corner. A qualified contractor should evaluate and repair or replace as necessary.  Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

5.19.1 – Decks & Balconies
WORN – SURFACES

The deck had visible indications of bare or worn-out surfaces. A qualified contractor should evaluate and repair or replace as necessary.

5.21.1 – Railings & Handrails
HORIZONTAL RAILINGS

The guard/handrail had horizontal railings. This creates a climbing risk and a fall or injury could occur if not corrected. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

5.21.2 – Railings & Handrails

SPINDLE SPACING OVER 4″

Improper spacing was noted between balusters, spindles, and rails. This is a safety hazard, especially for small children.

Guards may not allow the passage of a sphere 4 inches in diameter.

Correction and further evaluation are recommended.

5.22.1 – Roof Drainage – Downspouts & Extensions
EXTENSIONS TOO SHORT

One or more downspout extensions were too short. Recommend installing 6-8ft long (or greater as needed) extensions to divert rainwater runoff away from the property.

5.22.2 – Roof Drainage – Downspouts & Extensions
MISSING – EXTENSIONS

Downspout(s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 6 – Attached Garage EDIT SECTION
6.2.1 – Occupant Door
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

6.2.2 – Occupant Door
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Ceiling, Walls & Firewalls
FIREWALL BREAK – ATTIC ACCESS

An attic access panel in the ceiling of the garage was not properly trimmed or sealed and is considered a break in the firewall between the garage and habitable areas.

Should the interior attic span across the entire structure, the attic access should be installed according to current fire rating standards. Alternatively, there may be a wall to separate the garage and the house or attic space. This wall must be covered with at least 1/2-inch thick (and preferably 5/8-inch thick Type X) gypsum board or equivalent applied to the garage side.

Recommend a qualified contractor evaluate and repair or replace as needed.

6.4.1 – Floor
CRACKING – MODERATE

The concrete floor in the garage was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

6.4.2 – Floor
SIGNS OF REPAIR

Signs of repairs were present in the garage floor. Recommend asking current homeowner for more information, and if repairs appear to be of poor quality it is recommended to have a qualified contractor evaluate further for any additional repairs necessary.

6.5.1 – Vehicle Door
NOT SEALED AT FLOOR

The garage door was missing weather stripping or did not evenly seal at the floor or sides of the door. A qualified contractor should evaluate and make adjustments, repair, or replace as necessary.

6.5.2 – Vehicle Door
WEAK SPRINGS

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.

Recommend a qualified contractor evaluate and repair or replace as necessary.

6.6.1 – Door Opener
NOT WORKING – LIGHT BULB

The garage door opener had a light bulb that was not working. Recommend a qualified contractor evaluate and repair or replace as needed.

6.6.2 – Door Opener
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

6.7.1 – Electrical Outlets & Fixtures
NO GFCI PROTECTION

The garage had one or more outlets without GFCI (or ground fault circuit interrupter) protection.

GFCI protection is required for all 15- and 20-amp receptacles, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage. A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Stairs & Railings
RISER TOO TALL, OVER 7 3/4″

The stair riser height is more than what is accepted for current safety standards.

The riser height maximum is 7 3/4 inches measured vertically between the stair treads. This poses a trip hazard.

Recommend a qualified contractor evaluate and repair or replace as needed.

 7 – Interior, Doors, Windows EDIT SECTION
7.2.1 – Ceilings & Walls
ASBESTOS CEILING

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

7.3.1 – Floors
SLOPED
BASEMENT

Floor has a dip or is sloped in areas.

Recommend a qualified contractor evaluate and repair or replace as needed.

7.5.1 – Windows
NO EGRESS

At the time of the inspection, the property did not have emergency escape and rescue openings which met generally-accepted current standards. Egress opening requirements:

For safety reasons, all sleeping room and basements greater than 200 square feet and new properties should meet the generally-accepted current standards for emergency escape and rescue openings, which include the following requirements:

1. Sill height shall not exceed 44 inches above the floor.

2. Minimum net clear opening shall be 5.7 square feet; exception – grade level windows

may have a minimum clear opening of 5 square feet.

3. Minimum net clear opening height shall be 24 inches.

4. Minimum net clear opening width shall be 20 inches.

 

 

7.8.1 – Stairways & Railings
NOT CONTINUOUS

An interior handrail was not continuous throughout an interior stairway.

Handrails for stairs must be continuous for the full length of the stairway.

7.8.2 – Stairways & Railings
SPINDLE SPACING OVER 4″

At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary.

7.11.1 – Fireplace Wood-Burning
INADEQUATE HEARTH EXTENSION

The fireplace had inadequate clearance at the hearth extension component in front of the fireplace opening. InterNACHI recommends that for fireplaces that have an opening of 6 square feet or smaller, a hearth should extend at least 16 inches out into the room from the opening, and by at least 8 inches away from the sides. A qualified contractor should evaluate and repair or replace as necessary.

 8 – Kitchen EDIT SECTION
8.6.1 – Electrical Outlets
NO GFCI PROTECTION

No ground fault circuit interrupter (GFCI) protection was provided for kitchen electrical outlets. Although GFCI protection of kitchen circuits may not have been required at the time in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing kitchen electrical circuits to provide GFCI protection. This can be achieved by:

 

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary.

 9 – Laundry EDIT SECTION
9.9.1 – Electrical Outlets
GFCI PROTECTION NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom EDIT SECTION
10.3.1 – Exhaust Fan
WEAK

The bathroom exhaust fan was weak. A qualified contractor should evaluate and repair or replace as necessary.

10.9.1 – Cabinets & Counters
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.1 – Drain Waste and Vent System
NOT WORKING – SINK STOPPER

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.1 – Plumbing Fixtures
LOOSE IN WALL – SHOWER ARM
2ND FLOOR BATHROOM

A shower supply arm was loose in the wall.  This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

 11 – Bathroom 2 EDIT SECTION
11.4.1 – Ceilings & Walls
SIGNS OF REPAIR-CEILINGS

The ceilings had signs of previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 3 EDIT SECTION
12.7.1 – Electrical Outlets
WILL NOT RESET
BASEMENT BATHROOM

A GFCI outlet was defective and will not reset once tripped. A qualified contractor should evaluate and repair or replace as necessary.

12.15.1 – Fixture Valve Installation And Temperature
SINK REVERSED

The water supply valves and supply lines at the sink fixture in the bathroom were installed improperly with a reversed configuration. Current standards for installation produce hot water when the valve is turned to the left and cold water when the valve is turned to the right. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Plumbing EDIT SECTION
13.4.1 – Water Pressure
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

13.5.1 – Drain, Waste, & Vent Systems
FLOOR DRAIN BACKING UP
BASEMENT LAUNDRY AREA

The floor drain in the basement laundry room has fresh moisture around the drain that was not there half an hour ago. A qualified plumber should investigate and repair or replace as necessary.

 14 – Electrical EDIT SECTION
14.2.1 – Distribution Panels
SCREWS MISSING – PANEL COVER

Screws / fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

14.7.1 – Service Grounding & Bonding
GROUND ROD NOT FLUSH

The grounding rod is not flush with or below grade level. A qualified contractor should evaluate and repair or replace as necessary.

 15 – Water Heating Equipment EDIT SECTION
15.4.1 – Expansion Tank / Valve
NOT SECURED

The expansion tank was not properly secured. A qualified contractor should evaluate and repair or replace as necessary.

15.5.1 – Draft Diverter & Exhaust Flue
B VENT CLEARANCE 1″

The gas-fired water heater has a B vent exhaust flue with improper clearance from combustible materials. This type of vent is double walled and requires 1-inch minimum clearance. This condition is a potential fire hazard. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

15.12.1 – Operation & Response to Controls
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

15.13.1 – Water Temperature
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

 16 – Heating EDIT SECTION
16.2.1 – Exhaust Flue
B-VENT CLEARANCE UNDER 1″

The B-Vent (double wall) exhaust flue had improper clearance from combustible materials. This type of vent requires a 1-inch minimum clearance from combustibles. This condition is a potential fire hazard. A qualified contractor should evaluate and repair or replace as necessary.

 17 – Cooling EDIT SECTION
17.2.1 – AC Refrigerant Lines
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

17.3.1 – AC Compressor
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

17.3.2 – AC Compressor
COIL FINS DAMAGED

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

17.3.3 – AC Compressor
RUSTED COMPONENTS

Surface and/or interior components of the AC condenser showed rust in areas. Recommend a qualified contractor evaluate, service, and repair or replace as necessary.

 18 – Structural Basement EDIT SECTION
18.2.1 – Basement Floor
CRACKED – COMMON

The concrete floor in the basement was cracked in areas. These cracks appear to be common cracks indicating regular settlement or heaving, but not necessarily structural problems. Recommend a qualified contractor to evaluate to make further recommendations and repair as necessary.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

18.2.2 – Basement Floor
HEAVING & SETTLING OF CONCRETE FLOOR

Indications of movement/settling of the concrete floor were present in the basement area. This may be a compromise to the structural integrity of the foundation or structure of the house which only a qualified structural engineer could comment after further analysis.

Recommend a qualified structural engineer inspect further and provide a professional opinion related to this observation.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

18.5.1 – Moisture Intrusion
EFFLORESCENCE

Efflorescence (white powdery substance) on the wall indicates moisture is in contact with the concrete or masonry. This does not necessarily indicate that intrusion will occur. I recommend checking the gutters and the downspout drain lines for proper operation. Also, waterproofing paint could be applied to the interior side of the wall if necessary. Efflorescence is found on many properties without water intrusion occurring inside the property. But, it should alert you to the possibility that future steps may be needed. A qualified contractor should evaluate and repair as necessary.

18.5.2 – Moisture Intrusion
WATER DAMAGE AROUND PLUMBING

Water damage was visible in the crawlspace floor structure around plumbing lines. There may be a past or current leak in the nearby drain or supply lines that could further stain or rot wood if not corrected.

18.9.1 – Electrical in Basement
JUNCTION BOX MISSING COVER PLATE

The splice/Junction box was missing a cover plate. A qualified contractor should evaluate and repair or replace as necessary.

 19 – Sewer Scope EDIT SECTION
19.4.1 – Sewer Line Condition
CLOGGING

Clogging is found in the sewer line.

Consult a licensed plumbing contractor for service options.

19.4.2 – Sewer Line Condition
EXCESSIVE BUILD-UP

There is debris build-up in the line, we recommend clearing as needed to prevent further clogging. Recommend a qualified contractor clean as needed, and re-evaluate the system for any potential repairs or replacement.

19.4.3 – Sewer Line Condition
RECOMMEND HYDRO-JETTING

Hydro-jetting offers a comprehensive cleaning of your plumbing. The system uses, on average, 4000 psi. That level of pressure and the amount of water is sure to tackle even the smallest of dust particles. It clears out any obstructions, clogs, or build-up, allowing the water to run smoothly after. We always recommend consulting a professional for any work that gets done.

19.4.4 – Sewer Line Condition
SLUDGE

Sewer line sludge was observed. A service/cleaning line is recommended.

19.4.5 – Sewer Line Condition
STANDING WATER

Standing water was found in areas of the sewer line and may be caused by a lack of proper drain pitch or a back-up in the line.

Annual sewer cleaning/maintenance is suggested, further evaluation and repairs may be needed if the standing water problem worsens.

19.5.1 – Overall Recommendations
ANNUAL SEWER INSPECTION

An annual sewer scope inspection is recommended to monitor the condition of the sewer line.

19.5.2 – Overall Recommendations
FURTHER EVALUATION

We recommend that you consult with a licensed plumber for further evaluation, cleaning and any repairs needed. Consult with your Real Estate agent to ensure this happens prior to the inspection objection deadline date.

19.5.3 – Overall Recommendations
IMMEDIATE CLEANING

Recommend cleaning by a qualified drain cleaning contractor now and re-inspecting after to further evaluate lines’ condition. Consult with your Real Estate agent to ensure this happens prior to the inspection objection deadline date.