2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.2.2 – Roof Covering
Roof Covering 3
Roof Covering 4
DEGRANULATED

Some of the shingles appeared to be de-granulated in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.1 – Flashing
Flashing 1
Flashing 2
MEMBRANE IMPROPERLY INSTALLED

The roof membrane was installed underneath the drip edge flashing at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.2 – Flashing
Flashing 3
Flashing 4
EDGE FLASHING MISSING

The drip edge flashing along the rake/eave was missing in areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
RUBBER BOOT DAMAGED
One or more plumbing vents had a rubber boot flange that was damaged. This condition could allow moisture to penetrate the roof component.  A qualified contractor should evaluate,  then repair or replace as advised prior to the inspection objection deadline.
4 – Exterior EDIT SECTION
4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
CRACKING AND MOVEMENT
Cracking from apparent wall movement was present in the siding at the time of inspection.

Monitoring the walls of the house is needed. Most materials including masonry can deform elastically over long periods of time to accommodate small amounts of movement, large movements normally cause cracking.

Cracking can result from a variety of problems:

  • Differential settlement of the foundation
  • Drying shrinkage
  • Expansion and contraction due to ambient thermal and moisture variations
  • Improper support over openings
  • The effects of freeze-thaw cycles
  • The corrosion of iron and steel wall reinforcement
  • Differential movement between building materials; expansion of salts
  • The bulging or leaning of walls.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
DAMAGED – SIDING

The siding and/or trim was damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
PENETRATIONS

There were penetrations in areas of the siding at the time of inspection. Recommend applying appropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.

4.4.4 – Wall-Covering, Flashing & Trim

Wall-Covering, Flashing & Trim 5

Wall-Covering, Flashing & Trim 6
LOOSE – SIDING

The exterior wall-covering material was loose in one or more areas.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.5 – Wall-Covering, Flashing & Trim

Wall-Covering, Flashing & Trim 7

PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.6 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 8
Wall-Covering, Flashing & Trim 9

Wall-Covering, Flashing & Trim 10

SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.7 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 11
SIGNS OF REPAIRS

There were signs of previously repaired damage. Recommend inquiring with current homeowners for any further information. Should repairs be significant or failing, we recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.8 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 12
WOOD ROT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor evaluate and repair or replace as necessary.

4.10.1 – Window Wells
Window Wells 1
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Walkways
Walkways 1
CRACK AT STEP(S)

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.18.1 – Exterior Vents
Exterior Vents 1
VENT FLAP STUCK OPEN

The dryer vent had a flap that was stuck open. The clothes dryer vent may be clogged which is a potential fire hazard. This may also allow rodents or insects to enter the interior.  Recommend qualified contractor should evaluate and clean, repair, or replace as necessary.

4.19.1 – Decks & Balconies
Decks & Balconies 1
IMPROPER FOOTING – SUPPORT POST

A support post was not properly rested on a concrete footer or missing metal connection hardware. This may put the wood in direct contact with the moisture on the ground and accelerate any potential deterioration.

A qualified contractor should evaluate and repair or replace as necessary.

5 – Attached Garage
5.4.1 – Floor
Floor 1
HEAVING/SETTLING

Indications of movement from heaving/settling of the concrete floor were present in the garage. Significant movement may be a compromise the structural integrity of the foundation or structure of the garage which only a qualified structural engineer could comment after further analysis.

Recommend a qualified structural engineer inspect further and provide a professional opinion related to this observation.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-400-8148

5.6.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

 
6 – Interior, Doors, Windows
6.4.1 – Doors
Doors 1
CANNOT CLOSE

The basement door would not close; hits the frame. A qualified contractor should evaluate and repair or replace as necessary.

6.4.2 – Doors
Doors 2
SWINGS OPEN/CLOSED

The door swings open or closed by itself.  A qualified contractor should evaluate and repair or replace as necessary.

8 – Laundry
8.2.1 – Doors
Doors 3
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Electrical Outlets
Electrical Outlets 1
GFCI PROTECTION NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
DIDN’T POP UP – SINK STOPPER

The sink drain stop did not pop up allowing the water to drain.  A qualified contractor should evaluate and repair or replace as necessary.

10 – Bathroom 2
10.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

10.13.1 – Toilets
Toilets 1
FLUSH-HOLD LEVER DOWN

The toilet won’t flush unless the lever is held down briefly.  A qualified contractor should evaluate and repair or replace as necessary.

10.13.2 – Toilets
Toilets 2
FLUSH WEAK

The toilet flush very slowly. This may indicate the presence of a clog or obstruction in the toilet or sewer drain. A qualified contractor should evaluate and repair or replace as necessary.

11 – Bathroom 3
11.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

11.7.1 – Electrical Outlets
Electrical Outlets 1
NOT GROUNDED – GFCI OUTLET

A GFCI outlet was not grounded and did not trip when tested. A GFCI requires a ground wire to route electricity when tripped. A qualified contractor should evaluate and repair or replace as necessary.

11.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

11.9.2 – Cabinets & Counters
Cabinets & Counters 2
LOOSE – CABINETRY
The base cabinetry was loose and not securely fastened to the wall.  A qualified contractor should evaluate and repair or replace as necessary.
13 – Electrical
13.2.1 – Distribution Panels
Distribution Panels 1
OPEN KNOCKOUT – BREAKER

Unused circuit-breaker panel opening was missing filler plate. A qualified contractor should evaluate and repair and replace as necessary.

13.5.1 – Electrical Circuit Breakers
 Electrical Circuit Breakers 1
DIFFERENT BRANDS

Some or all circuit breakers were a brand different from the main panel brand. Circuit breakers made by different manufacturers vary in design, therefore panel manufacturers require their own manufactured breakers to be used. Select brands are interchangeable, and there are some “semi” universal breaker types or panel types.

Using incompatible breakers in the panel of another manufacturer may result in poor connections which can create a potential fire or shock/electrocution hazard. A qualified contractor should evaluate and repair or replace as necessary.

14 – Water Heating Equipment
14.8.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
Temperature & Pressure Relief Valve 2
LEAKING – TPR VALVE

The TPR Valve at the water heating equipment was leaking. A qualified contractor should evaluate and repair or replace as necessary.

16 – Cooling
16.3.1 – AC Compressor
AC Compressor 1
AIR FLOW RESTRICTED

Air flow to the air-conditioner condenser coils was restricted by vegetation, dirt, or debris. The unit should be cleaned and anything restricting air flow in or around the air conditioner should be removed in order to maintain cooling system efficiency and avoid problems from overheating of the compressor.

19 – Structural Crawlspace
19.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
NO BARRIER
No soil cover was installed at the time of the inspection. Soil covers help reduce humidity levels in crawlspaces by limiting moisture evaporation into the air from soil. Reducing humidity levels can help reduce the chances for mold growth and deterioration of structural components. A qualified contractor should evaluate and install a soil cover as necessary.