4 – Detached Garage
4.7.1 – Door Opener
Door Opener 1
NOT OPERATIONAL – OPENER BUTTON

The push button opener on the wall did not work.

5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls
Ceilings & Walls 1
DOOR KNOB HOLE

The wall was damaged or dented from the door knob.  A qualified contractor should evaluate and repair or replace as necessary.

5.2.2 – Ceilings & Walls
Ceilings & Walls 2
SIGNS OF REPAIR-CEILINGS
LIVING ROOM

The interior ceilings have signs of repairs. Recommend asking the current homeowner for more information. Recommend further evaluation from a qualified contractor should the repairs be excessive or of visibly poor quality.

5.3.1 – Floors
Floors 1
CARPET STAINS

The carpet was stained in areas. A qualified contractor should evaluate and repair or replace as necessary.

5.3.2 – Floors
Floors 2
CARPET DAMAGED

The carpet was damaged in areas. A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Doors
Doors 1
MISSING – DOOR
2ND FLOOR RIGHT BEDROOM CLOSET

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.2 – Doors
Doors 2
Doors 3
Doors 4
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

5.6.1 – Electrical Outlets
Electrical Outlets 1
DEFECT – FACEPLATE
LIVING ROOM

An electrical outlet had a loose or damaged faceplate. A qualified contractor should evaluate and repair or replace as necessary.

5.6.2 – Electrical Outlets

Electrical Outlets 2

MISSING – FACEPLATE

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

5.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
2ND FLOOR

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper level.

5.10.1 – Fireplaces Gas/LP
Fireplaces Gas/LP 1
FIREPLACE – DIRTY

Excessive lint, dust and/or debris was built up in the  pilot ignition compartment. Recommend further evaluation and proper cleaning by a qualified professional.

6 – Exterior – Condo/Townhome
6.1.1 – Exterior Doors

Exterior Doors 1

MISSING – HARDWARE

Hardware was missing at an exterior entry door.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

7 – Kitchen
7.2.1 – Doors
Doors 1
MISSING – FLOOR GUIDES

The door had missing or damaged floor guides.  A qualified contractor should evaluate and repair or replace as necessary.

7.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
KITCHEN

A fixture or bulb was not responding to switches at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

7.14.1 – Range/Oven/Cooktop
Range/Oven/Cooktop 1
DIRTY, EXCESS GREASE

The oven had excess grease or was dirty at the time of inspection. Excess grease may be a fire hazard. Recommend a qualified contractor evaluate and clean as needed.

7.16.1 – Mounted Microwave
LOOSE CONTROL PANEL

The microwave display was loose. A qualified contractor should evaluate and repair or replace as necessary.

7.16.2 – Mounted Microwave
Mounted Microwave 1
LIGHT NOT WORKING

The microwave light was not working.  A qualified contractor should evaluate and repair or replace as necessary.

8 – Laundry
8.2.1 – Doors
Doors 1
MISSING – DOOR
LAUNDRY AREA

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
PRIMARY BATHROOM

One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

9.9.1 – Cabinets & Counters
LOOSE – HINGES
PRIMARY BATHROOM

Cabinet door hinges were loose at time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

10 – Bathroom 2
10.4.1 – Ceilings & Walls
Ceilings & Walls 1
MINOR CRACKS-CEILING
UPSTAIRS BATHROOM

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – TUB/SHOWER DRAIN
UPSTAIRS BATHROOM

The tub/shower drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

11 – Bathroom 3
11.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 2
CLOGGED/SLOW – SINK DRAIN
1/2 BATHROOM

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

12 – Plumbing
12.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

12.7.1 – Sump Pit
NOT RESPONDING

The property had a sump pump. The sump pump did not respond to the controls. A qualified contractor should evaluate and repair/replace as necessary.

This system protects the property from water intrusion by discharging rising groundwater or seepage from surface runoff to the exterior of the property or to a waste pipe or storm drain. Sump pumps require periodic maintenance to ensure that they work when they’re needed and should be tested on an annual basis to ensure they are in working order. The pumps can be tested by lifting the float, but to avoid potential shock/electrocution hazard testing should be performed using a tool which will not conduct electricity. Pumps have a filter that should be cleaned during routine maintenance.

13 – Electrical
13.2.1 – Distribution Panels
Distribution Panels 1
SCREWS SHARP – PANEL COVER

Sharp screws / fasteners we used at the electrical panel cover. This could be potentially hazardous if the screws puncture a live electrical wire. A qualified contractor should evaluate and repair or replace as necessary.

14 – Water Heating Equipment
14.1.1 – General Information
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

15 – Heating
15.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

15.1.2 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.

15.9.1 – Air Filter
Air Filter 1
Air Filter 2
VERY DIRTY

The HVAC system air filter was very dirty or clogged. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

17 – Structural Crawlspace
17.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
BARRIER DAMAGED

The crawlspace vapor barrier was damaged in some areas, which compromises its effectiveness in reducing moisture and/or radon levels. A qualified contractor should evaluate and repair or replace as necessary.

17.3.1 – Moisture Intrusion
Moisture Intrusion 1
Moisture Intrusion 2
MOISTURE INTRUSION

There were water stains or water damaged areas in the crawlspace at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

17.5.1 – Foundation Wall
Foundation Wall 1
MINOR CRACKS

There were several cracks in the crawlspace foundation wall. These cracks should be sealed to prevent moisture intrusion, and monitored for further movement. Further analysis by a licensed structural engineer is recommended. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540.

17.6.1 – Insulation
Insulation 1
INSULATION NEEDED

There is no insulation on the crawlspace exterior walls or floor system. Heat loss can occur more on this property than one that is properly insulated. A qualified contractor should evaluate and install as necessary.