3 – Attic, Insulation and Ventilation
3.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor evaluate and repair or replace as needed.

4 – Exterior
4.4.1 – Wall-Covering, Flashing & Trim

Wall-Covering, Flashing & Trim 1

CRACKING – MINOR

Siding showed cracking and or damage in one or more places. Recommend monitoring, and if the problem exacerbates, a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.10.1 – Window Wells
Window Wells 1
Window Wells 2
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

4.10.2 – Window Wells
Window Wells 3
WINDOW WELL DAMAGED

Window Well(s) were damaged. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

4.10.3 – Window Wells
Window Wells 4
Window Wells 5
WINDOW WELL NO LADDER

Window well(s) lacked an egress ladder. Window wells more that 44″ below grade should have a permanent ladder installed. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
PIPE BENT/DAMAGED

Sprinkler system supply line pipe was bent or damaged at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

4.17.1 – Exterior Foundation Wall
Exterior Foundation Wall 1
Exterior Foundation Wall 2
CRACKS – AT CORNER(S)

The exterior foundation wall had cracks at the corner. A qualified contractor should evaluate and repair or replace as necessary.  Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540.

4.20.1 – Railings & Handrails
Railings & Handrails 1
MISSING – HANDRAIL

A stairway of more than 3 steps or drop of over 30″ was missing a handrail.

 

5 – Attached Garage
5.9.1 – Stairs & Railings
Stairs & Railings 1
MISSING – HANDRAIL

A stairway of more than 3 steps is missing a handrail. This condition may be a safety hazard if not corrected.

Correction and further evaluation is recommended.

15 – Water Heating Equipment
15.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

17 – Cooling
17.4.1 – AC Service Disconnect
AC Service Disconnect 1
PANEL HOUSING DAMAGED

The electrical service disconnect for the air conditioning condenser was damaged at panel housing. A qualified contractor should evaluate and repair/replace as necessary.