2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
DEBRIS

The roof was covered with debris in areas. This condition could trap moisture and conceal damage. Latent defects may exist. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.1 – Flashing
Flashing 1
Flashing 2
Flashing 3
VENT FLASHING INSTALLED IMPROPERLY

The vent flashing, used to protect areas of the roof from moisture intrusion, appeared to be installed improperly. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.4.2 – Flashing
Flashing 4
VENT FLASHING MISSING

The vent flashing, used to protect areas of the roof from moisture intrusion, was missing in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
RUBBER BOOT DAMAGED

One or more plumbing vents had a rubber boot flange that was damaged. This condition could allow moisture to penetrate the roof component.  A qualified contractor should evaluate,  then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Masonry Chimney
Masonry Chimney 1
IMPROPER SUPPORT – TOO TALL

The chimney extends 5 feet or more above the roof surface without a proper brace to keep it secure. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.2 – Masonry Chimney
Masonry Chimney 2
MISSING – RAIN CAP/SPARK ARRESTOR

The chimney rain cap/spark arrestor was missing. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

A rain cap covers the top opening of the chimney flue liner and is usually combined with a spark arrestor.

A spark arrestor is used to prevent floating embers from a solid fuel fire setting light to a flammable roofing surface or falling onto other combustible materials on the ground. A spark arrestor typically consists of a double layer of metal mesh, which catches the ember and allows the flue gas to escape. Spark arrestors also help prevent animals from entering the chimney.

2.8.1 – Masonry Chimney 2
Masonry Chimney 2 1
MISSING – RAIN CAP/SPARK ARRESTOR

The chimney rain cap/spark arrestor was missing. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

A rain cap covers the top opening of the chimney flue liner and is usually combined with a spark arrestor.

A spark arrestor is used to prevent floating embers from a solid fuel fire setting light to a flammable roofing surface or falling onto other combustible materials on the ground. A spark arrestor typically consists of a double layer of metal mesh, which catches the ember and allows the flue gas to escape. Spark arrestors also help prevent animals from entering the chimney.

2.9.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
Roof Drainage Systems 3
DEBRIS IN GUTTERS
MOST AREAS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3 – Attic, Insulation and Ventilation
3.1.1 – Attic Access
Attic Access 1
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

3.1.2 – Attic Access
Attic Access 2
Attic Access 3
OPENING TOO SMALL

The attic hatch was not the proper size to access the attic itself. The rough framed opening must measure a minimum of 22 by 30 inches to allow a full-grown adult to safely enter and exit. Should there be an appliance in the attic, the dimensions may be required to increase to allow the appliance to be removed.

The 2012 International Residential Code requires an attic access opening for attics with an area greater than 30 square feet and a vertical height in excess of 30 inches.

3.2.1 – Attic Structural Components
Attic Structural Components 1
SIGNS OF REPAIRS
NEW DECKING MOST AREAS

Visible signs of repairs were noted in the roof structure/decking. Recommend asking current homeowners for more information. Recommend further evaluation by a qualified professional if repairs appear to be poorly done or failing in the future.

3.4.1 – Insulation in Attic
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor evaluate and repair or replace as needed.

4 – Exterior
4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.6.1 – Exterior Doors
Exterior Doors 1
DAMAGE – WEATHER STRIPPING

An entry door had damaged or deteriorated weather stripping at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised.

4.6.2 – Exterior Doors
Exterior Doors 2
GAP AROUND DOOR

An exterior entry door had an opening that was too wide leaving a gap or daylight around the door.  A qualified contractor should evaluate and repair or replace as necessary.

4.6.3 – Exterior Doors
Exterior Doors 3
RUBS FRAME

An entry door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

4.8.1 – Electrical Outlets
Electrical Outlets 1
Electrical Outlets 2
NO EXTERIOR GFCI PROTECTION

No Ground Fault Circuit Interrupter (GFCI) protection was provided for the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

4.8.2 – Electrical Outlets
Electrical Outlets 3
LOOSE OUTLET

An exterior electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.3 – Electrical Outlets
Electrical Outlets 4
Electrical Outlets 5
MISSING WEATHERPROOF COVERING
BOTH

The exterior electrical outlet was missing an in-use weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.1 – Windows
Windows 1
Windows 2
Windows 3
MISSING – SCREEN
MULTIPLE MOST

A window was a missing a window screen.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.2 – Windows
Windows 4
MISSING TOP FLASHING

The top window flashing was missing around the subject property. Recommend a qualified contractor evaluate and repair or replace as needed.

4.11.1 – Walkways
Walkways 1
Walkways 2
HEAVING AND/OR SETTLING

The walkway(s) showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
INADEQUATE CLEARANCE GRADE
DETACHED GARAGE

The top of the foundation wall had inadequate clearance from grade. The top of the foundation wall should be a minimum of six inches above soil. Inadequate clearance may result in moisture intrusion of the structure.

Recommend a qualified contractor should evaluate and repair as necessary according to current standards.

4.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
Vegetation, Grading & Drainage 3
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.12.3 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 4
Vegetation, Grading & Drainage 5
Vegetation, Grading & Drainage 6
TREE BRANCHES OVER PROPERTY

Large trees near the house have branches which overhang the property. Falling branches due to conditions such as wood decay, high winds or heavy snow loads may cause injury, death or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
INADEQUATE CLEARANCE

The outside water faucet is installed close to the ground/floor or wall. A hose would likely be difficult to attach. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.17.1 – Exterior Foundation Wall
Exterior Foundation Wall 1
Exterior Foundation Wall 2
SIGNS OF REPAIR

The exterior foundation wall had signs of repair. Recommend inquiring with the current sellers for more information. Recommend further evaluation by a qualified contractor if the quality of work is poor.

4.18.1 – Exterior Vents
Exterior Vents 1
VENT FLAP STUCK OPEN
OLD DRYER VENT

The dryer vent had a flap that was stuck open. The clothes dryer vent may be clogged which is a potential fire hazard. This may also allow rodents or insects to enter the interior.  Recommend qualified contractor should evaluate and clean, repair, or replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
Roof Drainage - Downspouts & Extensions 2
EXTENSIONS NOT POSITIONED PROPERLY

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor evaluate and repair or replace as necessary.

5 – Detached Garage
5.3.1 – Exterior Door
Exterior Door 1
Exterior Door 2
WEATHERED, WORN

An exterior entry door had a weathered or worn surface.

Recommend a qualified contractor evaluate and repair or replace as needed.

5.3.2 – Exterior Door
Exterior Door 3
NO LOCK
No lock or damaged lock for exterior entry door. Recommend qualified contractor evaluate and repair or replace as needed.
5.4.1 – Ceiling & Walls in Garage
Ceiling & Walls in Garage 1
Ceiling & Walls in Garage 2
MOISTURE INTRUSION

Garage walls/ceilings showed signs of moisture intrusion. Recommend a qualified contractor evaluate and find source of moisture to prevent further damage and/or mold.

5.4.2 – Ceiling & Walls in Garage
Ceiling & Walls in Garage 3
SIGNS OF REPAIRS
There were signs of previously repaired damage. Recommend inquiring with current homeowners for any further information. Should repairs be significant or failing, we recommend a qualified contractor should evaluate and repair or replace as needed.
5.6.1 – Vehicle Door
Vehicle Door 1
DOORS DO NOT OPEN ALL THE WAY

Doors not opening fully, will require some dirt removal and or re-hanging of the doors. Recommend qualified contractor evaluate and repair or replace as needed.

5.8.1 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 1
LOOSE OUTLET, MISSING COVER PLATE

An outlet or switch box was loose in the garage at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

6 – Detached Garage 2
6.4.1 – Ceiling & Walls in Garage
Ceiling & Walls in Garage 1
DAMAGED DRYWALL

Garage wall had damaged drywall. Recommend drywall contractor repair.

6.5.1 – Floor
Floor 1
CRACKED – COMMON

The concrete floor in the garage was cracked.

A qualified contractor should evaluate and repair as necessary.

6.8.1 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 1
DEFECT – WALL SWITCH

A defect was noted at a wall switch in the garage. Not installed properly.

Recommend a qualified contractor evaluate and repair or replace as needed.

6.8.2 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 2
Interior Outlets & Fixtures 5
Interior Outlets & Fixtures 3
MISSING – FACEPLATE

A garage outlet or switch box was missing a face plate at the time of inspection recommend a qualified contractor evaluate and repair or replace as needed.

6.8.3 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 4
NO GFCI PROTECTION

The garage had one or more outlets without GFCI (or ground fault circuit interrupter) protection.

GFCI protection is required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage. A qualified contractor should evaluate and repair or replace as necessary.

6.8.4 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 5
FLICKERING LIGHT

Flickering light, Light not working at time of inspection. Recommend qualified contractor evaluate and repair or replace as needed.

6.9.1 – Windows
Windows 1
WON’T OPEN
MOST

The inspector was unable to open the window using reasonable force. A qualified contractor should evaluate then repair or replace as advised.

6.11.1 – Shop Sink
Shop Sink 1
Shop Sink 2
SINK NOT WORKING

No water supplied to sink. Recommend qualified contractor evaluate and repair or replace as needed.

7 – Interior, Doors, Windows
7.2.1 – Ceilings & Walls
Ceilings & Walls 1
Ceilings & Walls 2
ACCESS HOLE

The drywall was cut out for an access hole.  A qualified contractor should evaluate and repair or replace as necessary.

7.2.2 – Ceilings & Walls
Ceilings & Walls 3
MINOR CRACKS-WALLS
Minor cracking was visible on the interior walls.  A qualified contractor should evaluate and repair or replace as necessary.
7.3.1 – Floors
Floors 1
SLOPED
MULTIPLE AREAS

Floor has a dip or is sloped in areas.

Recommend a qualified contractor evaluate and repair or replace as needed.

7.4.1 – Doors
STRIKE NOT LATCHING

The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

7.4.2 – Doors
Doors 1
NOT CLOSING TIGHT
The door needs a strike plate adjustment to close tightly.
7.4.3 – Doors
Doors 2
Doors 3
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

7.5.1 – Windows
Windows 1
DIFFICULT TO OPEN/CLOSE

A window had a sash that was difficult to slide or operate to get opened/closed.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.2 – Windows
Windows 2
GLASS BROKEN/CRACKED

The window had a cracked or broken glass pane.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.3 – Windows
Windows 3
LOCK DAMAGED/MISSING

The window had damaged or missing lock hardware.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.4 – Windows
Windows 4
SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.5 – Windows
Windows 5
STUCK SHUT

The window had a sash that was unable to be opened without excessive force, possibly from being painted or nailed shut.  A qualified contractor should evaluate and repair or replace as necessary.

7.6.1 – Electrical Outlets
Electrical Outlets 1
Electrical Outlets 1
NOT GROUNDED – OUTLET
BACK BEDROOM, KITCHEN

One or more electrical outlets were not grounded. A qualified contractor should evaluate and repair or replace as necessary.

7.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
MISSING – BULB

The light fixture was missing one or more bulbs. A qualified contractor should evaluate and repair or replace as necessary.

7.8.1 – Stairways & Railings
Stairways & Railings 1
MISSING – HANDRAIL

At the interior stairs, the handrail was missing.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
CO DETECTOR >15 FEET

Carbon monoxide detectors were installed greater than 15 feet of rooms used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage within a specified distance of each room lawfully used for sleeping purposes.

7.9.2 – Smoke & CO Detectors
Smoke & CO Detectors 2
DETECTOR “BEEPS”

A smoke or CO detector was beeping at the time of inspection, and likely has low battery life or the detector itself may be defective. Recommend further evaluation of all detectors to repair or replace as needed.

7.11.1 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
Fireplace Wood-Burning 2
DAMAGE TO FIREPLACE INTERIOR CHAMBER
CRACK BRICKS, NEEDS TUCK POINTING

The fireplace had damage to the interior chamber. A qualified contractor should evaluate and repair or replace as necessary.

7.11.2 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
DEFECT AT LINTEL

The fireplace had a defect at the lintel. A qualified contractor should evaluate and repair or replace as necessary.

8 – Kitchen
8.4.1 – Floors
Floors 1
SLOPED

Floor has a dip or is sloped in areas.

Recommend a qualified contractor evaluate and repair or replace as needed.

8.13.1 – Dishwasher
Dishwasher 1
DOOR RUBS CABINET/WALL

The dishwasher door rubbed the adjacent wall or cabinet when opening or closing.  A qualified contractor should evaluate and repair or replace as necessary.

9 – Laundry
DIFFICULT TO OPEN/CLOSE

A window had a sash that was difficult to slide or operate to get opened/closed.  A qualified contractor should evaluate and repair or replace as necessary.

9.11.1 – Dryer Vent Piping
NO VENT CONNECTION

No vent connection was provided for the dryer. Lack of proper dryer venting to the exterior may result in excessively high humidity levels which can damage property materials or components and may encourage the growth of microbes such as mold. Lack of proper dryer venting can also result in the accumulation of lint in the property. Lint is combustible and it’s accumulation is a potential fire hazard and a possible health hazard from the inhalation of particulates. The Inspector recommends proper installation of an Underwriter’s Laboratory (UL) approved dryer vent for safety reasons. Dryer vents should be clean annually to ensure that safe conditions continue to exist.

10 – Bathroom
10.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

11 – Bathroom 2
11.9.1 – Cabinets & Counters
Cabinets & Counters 1
NOT SMOOTH
WON’T CLOSE FLUSH

One or more cabinet or drawer does not operate smoothly. This could be an issue with the drawer not sliding on a proper guide track or a door being difficult to swing open/closed.

A qualified contractor should evaluate and repair or replace as necessary.

12 – Plumbing
12.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

12.5.1 – Drain, Waste, & Vent Systems
Drain, Waste, & Vent Systems 1
PVC-ABS CONNECTION

The was a direct connection of ABS and PVC drain line material which is not recommended.   A qualified contractor should evaluate and repair or replace as necessary.

13 – Electrical
13.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too.

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

13.5.1 – Electrical Circuit Breakers
Electrical Circuit Breakers 1
DIFFERENT BRANDS

Some or all circuit breakers were a brand different from the main panel brand. Circuit breakers made by different manufacturers vary in design, therefore panel manufacturers require their own manufactured breakers to be used. Select brands are interchangeable, and there are some “semi” universal breaker types or panel types.

Using incompatible breakers in the panel of another manufacturer may result in poor connections which can create a potential fire or shock/electrocution hazard. A qualified contractor should evaluate and repair or replace as necessary.

13.5.2 – Electrical Circuit Breakers
Electrical Circuit Breakers 2
DOUBLE TAP
SUBPANEL DETACHED GARAGE

One or more circuit breakers have two wires that are connected to a breaker designed for only one wire. This is known as a “double-tap” and is a defective condition. A qualified contractor should evaluate and repair or replace as necessary.

13.8.1 – Service Drop
Service Drop 1
INADEQUATE CLEARANCE

The service drop did not meet minimum clearances which is a major electrical hazard. Correction and further evaluation is recommended.

In general, a service drop must be at least:

  • 2 feet above the immediate roof decking
  • 3 feet away from an openable window or door
  • 10 feet above areas accessible only to pedestrians, such as porches or decks
  • 12 feet above the ground (grade) as well as sidewalks and residential driveway
  • 22 1/2 feet above a swimming pool
14 – Water Heating Equipment
14.3.1 – Pipe Connections
Pipe Connections 1
CORRODED – PIPE FITTINGS

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

14.6.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

14.7.1 – Gas Supply Shut-Off Valve
Gas Supply Shut-Off Valve 1
NO DRIP LEG

The gas supply line lacked a sediment or drip leg. This condition could allow small particles in the gas supply to enter the mechanical. A qualified contractor should evaluate then repair or replace as advised.

14.7.2 – Gas Supply Shut-Off Valve
Gas Supply Shut-Off Valve 2
GAS OFF
14.12.1 – Operation & Response to Controls
NOT FUNCTIONING
PILOT WON’T LIGHT

The water heater did not respond to controls or the demand for hot water and was not operational. A qualified contractor should evaluate and repair or replace as necessary.

15 – Heating
15.12.1 – Heating System Ignition & Operation
Heating System Ignition & Operation 1
Heating System Ignition & Operation 2
HEATING SYSTEM NOT OPERATIONAL

The heating system did not respond to demand for heat or did not function properly at the time of the inspection. No shut off switches were activated aside from the safety shut-off switch that is designed to kill power when the blower cabinet cover is removed. A qualified contractor should evaluate and repair or replace as necessary.

17 – Structural Basement
17.2.1 – Basement Floor
Basement Floor 1
UNFINISHED
Unfinished Dirt floor present at time of inspection. Recommend vapor barrier or concrete. Recommend qualified contractor evaluate and repair or replace as needed.
17.3.1 – Foundation Wall
Foundation Wall 1
HORIZONTAL CRACKS

Horizontal cracking was observed in the basement foundation wall(s). Horizontal cracks are often serious, and are usually caused by hydrostatic pressure (too much water behind the foundation). Poor drainage and grading of soil around a structure can cause water to drain slowly. This water will saturate the ground around the foundation walls, causing an increase in hydrostatic (water) pressure. As the combined forces of hydrostatic pressure and the natural weight of the soils surrounding the foundation bear down, it can exceed the weight-bearing capacity of the walls, causing them to crack, bow, or shear. Further analysis by a licensed structural engineer is recommended. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540.

17.5.1 – Moisture Intrusion
Moisture Intrusion 1
Moisture Intrusion 2
EFFLORESCENCE

Efflorescence (white powdery substance) on the wall indicates moisture is in contact with the concrete or masonry. This does not necessarily indicate that intrusion will occur. I recommend checking the gutters and the downspout drain lines for proper operation. Also, a water proofing paint could be applied to the interior side of the wall if necessary. Efflorescence is found on many properties without water intrusion occurring inside the property. But, it should alert you to the possibility that future steps may be needed. A qualified contractor should evaluate and repair as necessary.

17.5.2 – Moisture Intrusion
Moisture Intrusion 3
WATER DAMAGE AROUND PLUMBING

Water damage was visible in the crawlspace floor structure around plumbing lines. There may be a past or current leak in the nearby drain or supply lines that could further stain or rot wood if not corrected.

17.6.1 – Floor Structure & Supports
Floor Structure & Supports 1
Floor Structure & Supports 2
POSTS NOT LEVEL

Structural posts and/or beams are not plumb/level, and may not be providing the structural support as intended. Further analysis by a licensed structural engineer is recommended.  Axium recommends our premier partner – Level Engineering.  They can be contacted at 720-706-8540.

17.6.2 – Floor Structure & Supports
Floor Structure & Supports 3
MODIFICATIONS
NEW SUBFLOR IN AREAS

Modifications repairs or additions were present in the floor structure support system. Recommend qualified contractor evaluate and repair or replace as needed.

17.6.3 – Floor Structure & Supports
Floor Structure & Supports 4
Floor Structure & Supports 5
Floor Structure & Supports 6
CONCRETE BLOCKS INSTALLED WRONG DIRECTION
ALL

Concrete blocks installed wrong direction, Concrete blocks are meant to be installed with holes running vertically. Recommend a qualified contractor evaluate and repair or replace as needed.

17.6.4 – Floor Structure & Supports
Floor Structure & Supports 7
Floor Structure & Supports 8
CRACKED OR SPLIT WOOD
Cracked or split wood Of floor structure in areas. Recommend qualified contractor evaluate and repair or replace as needed.
17.9.1 – Electrical in Basement
Electrical in Basement 1
EXPOSED ELECTRICAL SPLICES

Exposed electrical conductor splices need to be installed inside a junction box with cover plate. A qualified contractor should evaluate and repair or replace as necessary.

17.9.2 – Electrical in Basement
Electrical in Basement 2
DEFECT – LIGHT FIXTURE
MISSING BULB

Light fixtures in basement not working and/or missing bulbs at time of inspection. Recommend a qualified contractor evaluate and repair a replace as needed.

17.9.3 – Electrical in Basement
Electrical in Basement 3
OUTLET MISSING FACEPLATE

Outlet box was missing a cover plate. A qualified contractor should evaluate and repair or replace as necessary.