2 – Roof

2.2.1 – Roof Covering
Roof Covering 1
ALLIGATORING

The roof covering material had an “alligatored” look.   A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.2.2 – Roof Covering
Roof Covering 2
Roof Covering 3
Roof Covering 4
MINOR DAMAGE/EROSION

The roof covering material had minor damage or erosion in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation and Ventilation
3.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor evaluate and repair or replace as needed.

3.6.1 – Electrical Wiring In Attic
Electrical Wiring In Attic 1
JUNCTION BOX MISSING COVER PLATE

Splice/Junction box was missing a cover plate. A qualified contractor should evaluate and repair or replace as necessary.

 4 – Exterior
4.3.1 – Garage Door Exterior
Garage Door Exterior 1
GAP AROUND DOOR

The door had an opening that was too wide leaving a gap or daylight around the door.  A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
INADEQUATE ROOF CLEARANCE

The siding was in direct contact with the roof covering materials in some areas at the time of inspection. This condition can cause deterioration of the bottom edge of the siding at these locations. Ideally, there should be a minimum clearance of at least 1 1/2 inches from the bottom of the siding material to the top of the roof covering material. Recommend further evaluation by a qualified contractor to repair or replace.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
Wall-Covering, Flashing & Trim 4
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 6
Wall-Covering, Flashing & Trim 7
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 8
Wall-Covering, Flashing & Trim 9
Wall-Covering, Flashing & Trim 10
WOOD ROT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor evaluate and repair or replace as necessary.

4.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
DAMAGE – FASCIA

The fascia was damaged in one or more areas.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.1 – Electrical Outlets
Electrical Outlets 1
MISSING WEATHERPROOF COVERING

The exterior electrical outlet was missing an in-use weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways
Walkways 1
IMPROPERLY SLOPED SURFACE
FRONT

The walkway(s) have a negative slope and drains towards the home in areas. This condition is prone to water penetration into the home structure. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
VINES ON SIDING

Vegetation growing on siding should be removed and kept away from eaves, woodwork, doors, chimneys, or other building components. They hold moisture against the wall, hide rot and other problems and are conducive conditions for termites, carpenter ants,  etc. The growth does not allow full inspection of the siding and can hide potential defects underneath.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
CORRODED – SPRINKLER SUPPLY VALVES

The lawn sprinkler system supply valves appeared to be corroded and/or leaking at time of inspection. A qualified contractor should evaluate and repair/replace as necessary according to current standards.

4.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
DRIPS AT KNOB
BACK

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.14.2 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 2
SIGNIFICANT LEAK – KNOB
FRONT

The outside water faucet had a significant leak from the knob/handle when the water pressure gauge was attached. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.19.1 – Decks & Balconies
Decks & Balconies 1
Decks & Balconies 2
CRACKED, SPLIT WOOD – DECK

Cracked or split boards were present at the deck.  This condition is a structural defect and potential safety hazard.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.2 – Decks & Balconies
Decks & Balconies 3
IMPROPERLY SUPPORTED – STRUCTURE
BACK

Deck structure was improperly supported. This may be that support posts were connected to the structure (girder, beams) laterally using lag bolts, or beams are incorrectly notched to posts. The beam(s) should be installed on top of or notched partially on top of the support posts. This is a structural defect that may result in injury if not corrected.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.3 – Decks & Balconies
Decks & Balconies 4
MISSING – LEDGER FLASHING

Flashing was missing at the ledger board. This flashing problem may allow water to enter into the wall cavity or building components. A qualified contractor should evaluate and repair or replace as necessary.

4.20.1 – Railings & Handrails
Railings & Handrails 1
LOOSE – HANDRAIL
FRONT

The guard/hand rail was loose and should be secured. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.20.2 – Railings & Handrails
Railings & Handrails 2
PULLING FROM STAIR SETTLING.

The front porch railing is starting to pull in a downward direction because the stairs are settling significantly. A qualified contractor should investigate and repair or replace as necessary.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Vehicle Door
Vehicle Door 1
NOT SEALED AT FLOOR
GARAGE

The garage door was missing weather stripping or did not evenly seal at the floor or sides of the door. A qualified contractor should evaluate and make adjustments, repair, or replace as necessary.

5.8.1 – Windows
Windows 1
MISSING – SCREEN
GARAGE

I observed a missing window screen.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.8.2 – Windows
Windows 2
STUCK SHUT
GARAGE

The window in the garage is stuck shirt. When unlocked and ordinary force is applied the window will not slide open. A qualified contractor should investigate and repair or replace as necessary.

5.9.1 – Stairs & Railings
Stairs & Railings 1
LOOSE – HANDRAIL
GARAGE

The handrail is loose. This condition may be a safety hazard if not corrected.

Correction and further evaluation is recommended.

 6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
TAPE AND BED
LIVING ROOM

The drywall in some areas revealed the tape and nail bed. A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Floors
Floors 1
WEAR AND TEAR

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors
Doors 1
STRIKE NOT LATCHING
PRIMARY BEDROOM

The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

6.4.2 – Doors
Doors 2
RUBS FLOOR
BACK RIGHT BEDROOM

An interior door rubs on the flooring when opening or closing. Recommend a qualified contractor evaluate and repair or replace as needed.

6.5.1 – Windows
Windows 1
Windows 2
BROKEN SEALS
LIVING ROOM

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass was observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.2 – Windows
Windows 3
Windows 4
GLASS BROKEN/CRACKED
LIVING ROOM

The window had a cracked or broken glass pane.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.3 – Windows
Windows 5
Windows 6
SCREENS DAMAGED/MISSING
DINING ROOM

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.4 – Windows

Windows 7

Windows 8

Windows 9

STUCK SHUT
THROUGHOUT PROPERTY

The window had a sash that was unable to be opened without excessive force, possibly from being painted or nailed shut.  A qualified contractor should evaluate and repair or replace as necessary.

6.11.1 – Fireplaces Gas/LP
Fireplaces Gas/LP 1
GLASS CLOUDY
LIVING ROOM

The glass at the fireplace had a cloudy appearance. A qualified contractor should evaluate and repair or replace as necessary.

 7 – Kitchen
7.5.1 – Cabinets & Counters
Cabinets & Counters 1
GROUT – BACKSPLASH
KITCHEN

The tile backsplash had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.2 – Cabinets & Counters
Cabinets & Counters 2
Cabinets & Counters 3
OVERLAPPING
KITCHEN

Doors, handles, and/or drawers overlap and open into each other in the kitchen. This either restricts both items to be opened simultaneously, or requires one to be opened for another to be usable. Recommend a qualified contractor evaluate and repair or replace as necessary.

7.6.1 – Electrical Outlets
Electrical Outlets 1
Electrical Outlets 2
GFCI-NOT ALL PROTECTED
KITCHEN

Ground fault circuit interrupter (GFCI) Protection was not provided for all kitchen electrical outlets. Although GFCI protection of kitchen outlets may not have been required at the time in which this property was built, as general knowledge of say fielding practices has improved with the passage of time building standards have changed to reflect current understanding.  A qualified contractor should evaluate and repair or replace as necessary.

7.6.2 – Electrical Outlets
Electrical Outlets 3
Electrical Outlets 4
Electrical Outlets 5
OUTLET NOT GROUNDED
KITCHEN

An electrical outlet was not grounded. A qualified contractor should evaluate and repair or replace as necessary.

7.7.1 – Windows
Windows 1
STUCK SHUT
KITCHEN

The window had a sash that was unable to be opened without excessive force, possibly from being painted or nailed shut.  A qualified contractor should evaluate and repair or replace as necessary.

7.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
LEAKING
KITCHEN

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.6.1 – Cabinets & Counters
Cabinets & Counters 1
COUNTER-MISSING/DAMAGED GROUT

The counter top had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

8.6.2 – Cabinets & Counters
Cabinets & Counters 2
DRAWER DOES NOT STAY SHUT
LAUNDRY AREA

And installed drawer in the laundry room does not stay shut when closed. A qualified contractor should investigate and repair or replace as necessary.

8.8.1 – Floors
Floors 1
FLOOR DAMAGED
LAUNDRY AREA

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor evaluate and repair or replace as needed.

 9 – Bathroom
9.9.1 – Cabinets & Counters
Cabinets & Counters 1
GROUT – BACKSPLASH/WALL

The tile on the wall or backsplash had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN
PRIMARY BATHROOM RIGHT SINK

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.10.2 – Drain Waste and Vent System
Drain Waste and Vent System 2
CLOGGED/SLOW – TUB/SHOWER DRAIN
PRIMARY BATHROOM

The tub/shower drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
Plumbing Fixtures 2
DAMAGE – FAUCET FINISH
PRIMARY BATHROOM

The finish on the faucet is damaged.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.2 – Plumbing Fixtures
Plumbing Fixtures 3
CORRODED SINK STOPPER
PRIMARY BATHROOM

There are signs of corrosion on the sink stopper in the left hand sink in the primary bathroom. A qualified contractor should investigate and repair or replace as necessary.

9.14.1 – Tub, Shower Area
Tub, Shower Area 1
POSSIBLE MOLD
PRIMARY BATHROOM

Evidence of a possible mold like substance was observed bath or shower area.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

9.16.1 – Water Supply Functional Flow
PRESSURE DROP

With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.9.1 – Cabinets & Counters
Cabinets & Counters 1
GROUT – BACKSPLASH/WALL
2ND FLOOR BATHROOM

The tile on the wall or backsplash had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
Drain Waste and Vent System 2
Drain Waste and Vent System 3
LEAKING
2ND FLOOR BATHROOM

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
MISSING/DAMAGED GROUT
2ND FLOOR BATHROOM

Tiles on the wall in the bath/shower area had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

 11 – Bathroom 3
11.9.1 – Cabinets & Counters
Cabinets & Counters 1
GROUT – COUNTER TOP
1ST FLOOR BATHROOM

The counter top tiles had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 4
12.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

 13 – Plumbing
13.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 14 – Electrical
14.7.1 – Service Grounding & Bonding
Service Grounding & Bonding 1
GROUND ROD NOT FLUSH

The grounding rod is not flush with or below grade level. A qualified contractor should evaluate and repair or replace as necessary.

 15 – Water Heating Equipment
15.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH
KITCHEN

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

 16 – Heating
16.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.1.2 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

 17 – Cooling
17.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

17.2.2 – AC Refrigerant Lines
AC Refrigerant Lines 2
GAP AROUND LINE AT WALL

The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.

17.2.3 – AC Refrigerant Lines
AC Refrigerant Lines 3
EXCESSIVE CONDENSATION

The refrigerant lines were missing insulation and excessive condensation was present at the interior refrigerant lines near the air handler. The excess condensation appears to be dripping on to the HVAC unit. The excess condensation may cause damage and accelerated wear to the furnace and/or heating system as a whole if left uncorrected. Recommend a qualified contractor evaluate, service, and certify the HVAC unit is in good working order prior to closing deadline.

17.3.1 – AC Compressor
AC Compressor 1
AC Compressor 2
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.