2 – Roof
2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
TOO SHORT

A plumbing vent did not extend far enough above the roof. A plumbing vent should extend a minimum of 10″.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.7.1 – Electrical Fixtures
LOOSE ON WALL

An exterior light fixture was loose where mounted to the wall and should be secured tighter. A qualified contractor should evaluate and repair or replace as necessary.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
ERODED GRADE

Grade has eroded or was poorly back-filled near the foundation wall, patio, or stairway. This may allow moisture to pool near the structure, and this may allow significant cracking if not corrected.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
LEAKING

The sprinkler system supply line was leaking at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

4.16.1 – Gas Meter, Gas Shut-Off
Gas Meter, Gas Shut-Off 1
MINOR RUST

Pipes had minor surface rust at the gas meter. Monitoring and contacting a qualified professional to further evaluate for repairs is recommended

 5 – Attached Garage
5.5.1 – Vehicle Door
Vehicle Door 1
WEAK SPRINGS

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.

Recommend a qualified contractor evaluate and repair or replace as necessary.

 6 – Interior, Doors, Windows
6.3.1 – Floors
Floors 1

Floors 2

FLOOR SQUEAKS
BASEMENT

The floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors
Doors 1
Doors 2
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

6.7.1 – Electrical Fixtures & Switches

Electrical Fixtures & Switches 1

NOT WORKING – BULB(S)

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

6.7.2 – Electrical Fixtures & Switches
FAN WOBBLES
LIVING ROOM

The ceiling fan wobbles when operated and may need to be balanced.  A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Stairways & Railings
LOOSE – HANDRAIL

At the interior stairs, the handrail was loose.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

 7 – Kitchen
7.5.1 – Cabinets & Counters
Cabinets & Counters 1
LOOSE – HINGE

The cabinet hinge was loose and not securely fastened.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.2 – Cabinets & Counters
Cabinets & Counters 2
OVERHANG OVER 8″

The counter top extends greater than 8 inches over cabinets without proper support.  A qualified contractor should evaluate and repair or replace as necessary.

7.6.1 – Electrical Outlets
Electrical Outlets 1
GFCI OUTLET NOT GROUNDED

A GFCI outlet was not grounded and did not trip when tested.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.9.1 – Electrical Outlets
Electrical Outlets 2
GFCI PROTECTION NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
Plumbing Fixtures 2
LEAK – SINK CONTROL VALVE

A control valve at the sink was leaking during operation at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary.

9.13.1 – Toilets
LOOSE AT THE FLOOR
PRIMARY BATHROOM

The toilet was loose at the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. Loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
UPSTAIRS BATHROOM

One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

 11 – Bathroom 3
11.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 2
NOT WORKING – BULB
BASEMENT BATHROOM

One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

 12 – Plumbing
12.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

12.7.1 – Sump Pit
Sump Pit 1
NO PUMP/WATER LEVEL HIGH

The property contained a pit for a sump pump, but no pump was installed. The water level in the sump pit at the time of the inspection was higher than what is considered acceptable. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

A sump pump system protects the property from water intrusion by discharging rising groundwater or by routing surface drainage via the property perimeter drain to the pit, from where it is discharged by the pump to the exterior of the property or to a waste pipe or storm drain. Sump pumps require periodic maintenance to ensure that they work when they’re needed and should be tested on an annual basis to ensure they are in working order. The pumps can be tested by lifting the float, but to avoid potential shock/electrocution hazard testing should be performed using a tool which will not conduct electricity. Pumps have a filter that should be cleaned during routine maintenance.

 14 – Water Heating Equipment
14.1.1 – General Information
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

14.4.1 – Expansion Tank / Valve
Expansion Tank / Valve 1
NOT SECURED

The expansion tank was not properly secured. A qualified contractor should evaluate and repair or replace as necessary.

14.4.2 – Expansion Tank / Valve
Expansion Tank / Valve 2
CORRODED

The connection to the expansion tank was corroded at the time of the inspection

 15 – Heating
15.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

15.1.2 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

15.7.1 – Condensate
Condensate 1
SIGNS OF LEAKING

The condensation drain components for the HVAC system were leaking or showed signs of previous leaking. A qualified contractor should evaluate and repair or replace as necessary.

15.8.1 – Ductwork
Ductwork 1
DUCTS NOT SEALED

Air supply ducts were not sealed. Ideally all ducts are sealed with mastic in order to be more energy-efficient. A qualified contractor should evaluate and repair as necessary.

 16 – Cooling
16.1.1 – Cooling System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

16.1.2 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
GAP AROUND LINE AT WALL

The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.

16.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16.3.2 – AC Compressor
AC Compressor 2
RUSTED COMPONENTS

Surface and/or interior components of the AC condenser showed rust in areas. Recommend a qualified contractor evaluate, service, and repair or replace as necessary.

 17 – Structural Basement
17.5.1 – Moisture Intrusion
Moisture Intrusion 1
POSSIBLE MOLD

Evidence of a possible mold like substance was observed.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

 18 – Structural Crawlspace
18.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
NO BARRIER

No soil cover was installed at the time of the inspection. Soil covers help reduce humidity levels in crawlspaces by limiting moisture evaporation into the air from soil. Reducing humidity levels can help reduce the chances for mold growth and deterioration of structural components. A qualified contractor should evaluate and install a soil cover as necessary.

18.3.1 – Moisture Intrusion
Moisture Intrusion 1
Moisture Intrusion 2
EXCESSIVE GROUND MOISTURE

Areas of the crawlspace were visibly wet or soft/squishy under the vapor barrier. The ground showed signs of moisture intrusion. A qualified contractor should evaluate and repair or replace as necessary.

18.6.1 – Insulation
Insulation 1
INSULATION NEEDED

There is no insulation on the crawlspace exterior walls or floor system. Heat loss can occur more on this property than one that is properly insulated. A qualified contractor should evaluate and install as necessary.