2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
DEGRANULATED

Some of the shingles appeared to be de-granulated in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.3.1 – Roof Structure
Roof Structure 1
RIDGE/RAFTER SAG

The inspector observed that the roof ridge/rafter sagged visibly. This condition could increase unless the structural problem is corrected. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.5.1 – Skylight
Skylight 1
Skylight 2
Skylight 3CRACKED GLASS

The skylight glass was cracked/damaged at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.6.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
Plumbing Vent Pipes 2
INADEQUATE CLEARANCE

A plumbing vent appeared to lack proper clearance from a valley, sidewall, openable window, door, ventilation or air intake. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
CORRODED

One or more combustion exhaust flue(s) showed signs of rust/corrosion.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.2 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 2
INADEQUATE CLEARANCE – ROOF

One or more combustion appliance exhaust flue(s) did not extend far enough above the roof. To ensure proper and safe operation, exhaust flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally).  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.8.1 – Roof Drainage Systems
Roof Drainage Systems 1
BENT/DAMAGED

Gutters were bent and/or damaged at the time of the inspection.

This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.8.2 – Roof Drainage Systems
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.8.3 – Roof Drainage Systems
Roof Drainage Systems 3
LEAKING

Gutters were leaking and need maintenance such as the application of an appropriate sealant at the time of the inspection.  This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation and Ventilation
3.3.1 – Attic Moisture Intrusion
Attic Moisture Intrusion 1
WATER INTRUSION

Signs of previous water penetration or intrusion into the attic. Water marks or stains were observed. Recommend asking seller if there’s any recent incidents that have been documented or mitigated.

Further evaluation is recommended.

3.3.2 – Attic Moisture Intrusion
Attic Moisture Intrusion 2
RUSTY NAILS

Rusty nails often signal excess condensation build-up due to poor ventilation. Recommend a qualified contractor evaluate further to repair or replace as needed.

3.4.1 – Insulation in Attic
Insulation in Attic 1
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor evaluate and repair or replace as needed.

3.5.1 – Ventilation in Attic
VENTILATION INADEQUATE

Ventilation may have been insufficient at the time of the inspection.

Inadequate attic ventilation can cause the attic to overheat, causing heat damage to the roof covering, which results in a decreased life expectancy. Adequate ventilation of the attic will actually help prolong the life expectancy of the roof covering and help stabilize interior temperatures when heating and cooling is in use.

Recommend a qualified contractor evaluate to ensure all attic ventilation is unobstructed and fully functional and/or install additional ventilation as needed.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
DETERIORATED

The driveway was deteriorated or was eroded in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.3 – Driveways
Driveways 1
IMPROPERLY SLOPED SURFACE

The driveway has a negative slope and drains towards the home or garage. This condition is prone to water penetration into the home structure. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
DAMAGE – SOFFIT

The soffit was damaged in one or more areas.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.5.2 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 2
Eaves, Soffits & Fascia 3
MOISTURE DAMAGE

Components of the eaves, facia, and/or soffit was warped, swollen, or had peeling paint which are signs of water damage. The materials will eventually begin to rot if left untreated or cause has not been corrected.

A qualified contractor should evaluate and repair or replace as necessary.

4.5.3 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 4
BIRD NEST

Recommend  removing

4.5.4 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 5
WASP NEST

It Wasp nest is present at the time of inspection. Recommend removing by qualified contractor.

4.7.1 – Electrical Fixtures
Electrical Fixtures 1
DAMAGED – FIXTURE/COVER

The exterior light fixture or light cover was damaged. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

4.9.1 – Windows
Windows 1
DAMAGED – SCREEN

One or more window screens were damaged or deteriorated.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways
Walkways 1
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.2 – Walkways
Walkways 2
Walkways 3
DETERIORATED

The walkway(s) were deteriorated or was eroded in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
DENSE VEGETATION

Dense vegetation was present around the house in areas.  This condition limited and restricted my visual inspection.  Dense vegetation and landscaping up against or near the house foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning and some landscaping is recommended by a qualified contractor

4.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
Vegetation, Grading & Drainage 3
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.17.1 – Exterior Foundation Wall
Exterior Foundation Wall 1
MINOR DAMAGE TO CONCRETE

The visible concrete foundation wall surface was damaged or deteriorated in areas. Recommend a qualified contractor evaluate and repair or replace as needed.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
EXTENSIONS TOO SHORT

One or more down spout extensions were too short. Recommend installing 6-8ft long (or greater as needed) extensions to divert rainwater runoff away from the property.

4.21.2 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 2
MISSING – EXTENSIONS

Downspout(s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

5.2.2 – Occupant Door
Occupant Door 2
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Floor
Floor 1
CRACKING – MODERATE

The concrete floor in the garage was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

5.5.1 – Vehicle Door
Vehicle Door 1
NOT SEALED AT FLOOR

The garage door was missing weather stripping or did not evenly seal at the floor or sides of the door. A qualified contractor should evaluate and make adjustments, repair, or replace as necessary.

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.

Recommend a qualified contractor evaluate and repair or replace as necessary.

5.5.3 – Vehicle Door
NOT ABLE TO MANUALLY LIFT

The garage door was not able to be lifted manually at the time of inspection. The garage door likely need some adjustment. Recommend a qualified contractor evaluate and repair or replace as needed.

5.6.1 – Door Opener
Door Opener 1
MISSING – REVERSE SENSORS

The automatic reverse sensors are missing.

These are a safety feature to prevent injury, and should be installed no more than 6 inches away from the floor.

 6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
ASBESTOS CEILING

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

6.2.2 – Ceilings & Walls
Ceilings & Walls 2
Ceilings & Walls 3
Ceilings & Walls 4
MOISTURE DAMAGE-CEILINGS

The ceilings showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.3 – Ceilings & Walls
Ceilings & Walls 5
Ceilings & Walls 6
MOISTURE DAMAGE-WALLS

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.4 – Ceilings & Walls
Ceilings & Walls 7
MOISTURE STAINING-CEILINGS

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.5 – Ceilings & Walls
Ceilings & Walls 8
MINOR CRACKS-WALLS

Minor cracking was visible on the interior walls.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Floors
CARPET STAINS
ENTIRE PROPERTY

The carpet was stained in areas. A qualified contractor should evaluate and repair or replace as necessary.

6.3.2 – Floors
WEAR AND TEAR
ENTIRE HOME

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors
Doors 1
OFF TRACK

The sliding/folding door would fall off the track when operated.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.2 – Doors
Doors 2
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Windows
WORN OR NEARING THE END OF LIFE EXPECTANCY
ALL WINDOWS ON PROPERTY

Windows installed in the home appeared to be worn or aged. This apparent condition can mean the windows are deteriorated or difficult to operate, and can also mean they are not consistent with current efficiency standards. They were possibly original and were either at or near their serviceable lifespan. Recommend further evaluation by a qualified contractor and budgeting for potential future replacement.

6.5.2 – Windows
Windows 1
NO EGRESS

At the time of the inspection, the property did not have emergency escape and rescue openings which met generally-accepted current standards. Egress opening requirements:

For safety reasons, all sleeping room and basements greater than 200 square feet and new properties should meet the generally-accepted current standards for emergency escape and rescue openings, which include the following requirements:

1. Sill height shall not exceed 44 inches above the floor.

2. Minimum net clear opening shall be 5.7 square feet; exception – grade level windows

may have a minimum clear opening of 5 square feet.

3. Minimum net clear opening height shall be 24 inches.

4. Minimum net clear opening width shall be 20 inches.

6.6.1 – Electrical Outlets
Electrical Outlets 1
Electrical Outlets 2
OUTLET HOT AND NEUTRAL REVERSED

One or more electrical outlet(s) were wired incorrectly with the hot and neutral wires being reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created as there is still electricity running through the hot wire when the switch is off. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

6.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
FAN NOT WORKING

The ceiling fan did not work. A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Stairways & Railings
Stairways & Railings 1
SPINDLE SPACING OVER 4″

At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
CO DETECTOR MISSING

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper level.

6.9.2 – Smoke & CO Detectors
Smoke & CO Detectors 2
Smoke & CO Detectors 3
SMOKE DETECTOR MISSING

The smoke detector was missing. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

6.11.1 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
CLEANING NEEDED

The visible areas of the firebox and chimney flue were dirty at the time of the inspection. Most of the chimney flue was inaccessible and was not inspected. Dirty flues are potential fire hazards and should be cleaned by a professional. Recommend having the chimney evaluated by a C.S.I. (Chimney Safety Institute) -qualified chimney sweep.

 7 – Kitchen
7.4.1 – Floors
Floors 1
FLOOR DAMAGED

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor evaluate and repair or replace as needed.

7.5.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – CABINET

The base cabinet was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.2 – Cabinets & Counters
Cabinets & Counters 2
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years.

A qualified contractor should evaluate and repair or replace as necessary.

7.6.1 – Electrical Outlets
Electrical Outlets1
NO GFCI PROTECTION

No ground fault circuit interrupter (GFCI) protection was provided for kitchen electrical outlets. Although GFCI protection of kitchen circuits may not have been required at the time in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing kitchen electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary.

7.11.1 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 1
MISSING – SHUTOFF VALVE

There were no water supply valves installed at the sink at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

7.13.1 – Dishwasher
Dishwasher 1
NOT OPERATIONAL

The dishwasher was not operational at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

7.15.1 – Range Hood
Range Hood 1
DIRTY

The vent hood had a build up of grease and dirt.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.4.1 – Exhaust Fan
NO VENT NO WINDOW

The laundry room did not have an exhaust fan or an openable window. A qualified contractor should evaluate, then repair or replace as advised.

8.9.1 – Electrical Outlets
Electrical Outlets 1
GFCI PROTECTION NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

8.11.1 – Dryer Vent Piping
Dryer Vent Piping 1
KINKED/DAMAGED

A dyer vent connection was installed in the laundry area. The dryer vent was kinked and/or damaged at the back of the dryer.  The inspector recommends repair or replacing the dryer vent to prevent restricting dryer exhaust air flow, the restriction of which can result in lint accumulation or vent blockage which can cause the dryer to overheat; a potential fire hazard and a condition which will shorten the dryers life span. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.5.1 – Floors
Floors 1
WEAR AND TEAR

The floors showed signs of minor damage and wear – particularly in high traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

9.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
LOOSE – FIXTURE

The light fixture was loose and/or hanging. A qualified contractor should evaluate and repair or replace as necessary.

9.9.1 – Cabinets & Counters
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years.

A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
LEAKING

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

9.11.1 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 1
MISSING – SHUTOFF VALVE

There were no water supply valves installed at the sink at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CRACKED/DAMAGED – SINK

The sink was cracked or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
LOOSE IN WALL – SHOWER ARM

A shower supply arm was loose in the wall.  This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

9.12.3 – Plumbing Fixtures
Plumbing Fixtures 3
LEAK – TUB SPOUT

The tub spout leaked.  A qualified contractor should evaluate and repair or replace as necessary.

9.14.1 – Tub, Shower Area
Tub, Shower Area 1
Tub, Shower Area 2
POSSIBLE MOLD

Evidence of a possible mold like substance was observed bath or shower area.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

9.14.2 – Tub, Shower Area
Tub, Shower Area 3
DETERIORATED – CAULKING/GROUT

Caulking in the shower/tub area was deteriorated at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.2.1 – Doors
Doors 1
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

10.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE DAMAGE-WALLS

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

10.4.2 – Ceilings & Walls
Ceilings & Walls 2
MOISTURE STAINING-CEILINGS

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

10.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CRACKED/DAMAGED – SINK

The sink was cracked or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
DRIP – TUB WHEN OFF

The tub spout drips when off.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.3 – Plumbing Fixtures
Plumbing Fixtures 3
LOOSE IN WALL – SHOWER ARM

A shower supply arm was loose in the wall.  This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

10.12.4 – Plumbing Fixtures
Plumbing Fixtures 4
LEAK – SHOWER HEAD

There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

10.13.1 – Toilets
Toilets 1
FLUSH-HOLD LEVER DOWN

The toilet won’t flush unless the lever is held down briefly.  A qualified contractor should evaluate and repair or replace as necessary.

10.13.2 – Toilets
Toilets 2
LOOSE-TOILET TO TANK

The toilet was loose at the tank to toilet connection.  A qualified contractor should evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
DETERIORATED – CAULKING/GROUT

Caulking in the shower/tub area was deteriorated at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

 11 – Plumbing
11.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
DAMAGE – CLAMP, CONNECTOR, OR BUSHING

A clamp, connector, or bushing component at the electrical panel was damaged. A qualified contractor should evaluate and repair or replace as necessary.

12.2.2 – Distribution Panels
Distribution Panels 2
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too.

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

12.2.3 – Distribution Panels
Distribution Panels 3
OPEN KNOCKOUT – BREAKER

Unused circuit-breaker panel opening was missing filler plate. A qualified contractor should evaluate and repair and replace as necessary.

 13 – Water Heating Equipment
13.6.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

 14 – Heating
14.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

14.5.1 – Gas Supply Shut-Off Valve
Gas Supply Shut-Off Valve 1
GAS LEAK

Gas leakage was detected at one or more gas line connection or burner. This is a safety hazard which immediate repair by a qualified plumbing contractor is recommended. The gas supply piping included a shutoff valve in the vicinity of the heating system for service personnel and emergency use. The valve was not operated as part of the inspection. A qualified contractor should evaluate and repair or replace as necessary.

 15 – Structural Basement
15.5.1 – Moisture Intrusion
Moisture Intrusion 1
MOISTURE INTRUSION

The visible areas of the basement showed signs of possible previous moisture intrusion and/or deterioration. A qualified contractor should evaluate and repair or replace as necessary.

15.5.2 – Moisture Intrusion
 Moisture Intrusion 2
POSSIBLE MOLD

Evidence of a possible mold like substance was observed.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

 18 – Sewer Scope
18.3.1 – Sewer Line Condition
Sewer Line Condition 1
*MINOR TO MODERATE BUILDUP, DEBRIS, AND/OR SLUDGE

Sludge is a sticky concoction of soap scum, grease, hair, food particles, and even dissolved minerals in the water. Once a layer of sludge forms, more sludge tends to accumulate in that segment of the pipe, increasingly narrowing the size of the pipe until only a small channel allows free flow of water.

We recommend consulting a qualified drain cleaning contractor within a year to have the line cleaned and reinspected.

18.3.2 – Sewer Line Condition
Sewer Line Condition 2
Sewer Line Condition 3
*MODERATE TO SEVERE OFFSET(S)

An offset means that one section of a sewer pipe does not line up with the next, creating a gap or reduction in the effective opening of the pipe. Most of the time, an environmental change is usually at fault for an offset pipe. Settlement in the surrounding earth or root growth can cause the two sections of piping to shift independently. Occasionally, the problem is due to poor installation, but this is rare.

We rated this offset as moderate to severe. As the offset gets larger, and specifically if it is near the bottom edge of the pipe, then repair will likely be needed. We recommend consulting a qualified sewer line repair or replacement contractor to evaluate if further action is required.

18.3.3 – Sewer Line Condition
Sewer Line Condition 4
*STANDING WATER

The are one or more sections of standing water in the line. Ideally, all water should drain from the line, but areas of standing water will form when flow is restricted or significantly slowed. This is usually caused by improper pitch, bellies, or obstructions in the line. We recommend the line be cleaned by a qualified cleaning contractor and then reinspected to determine the cause of the standing water. A licensed plumber may need to be consulted to determine any necessary corrective actions.

18.3.4 – Sewer Line Condition
Sewer Line Condition 5
*PIPE DEFORMATION

Pipe deformation means that the pipe’s shape has been altered from its original form. The round pipe is compressed into an elliptical or oval shape. Other examples include indentations, bulges, and humps in the sewer line due to external pressure which can lead to buckling or even collapsed sections of the line. For significant* deformations, we recommend a qualified plumbing contractor evaluate the condition to determine if there is a need for repair or replacement.

18.4.1 – Overall Recommendations
**FURTHER EVALUATION

The main sewer line appears to be compromised. We recommend consulting with a sewer line repair/replacement contractor for further evaluation.