5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls

Ceilings & Walls 1

Ceilings & Walls 2

SIGNS OF REPAIR-CEILINGS

The interior ceilings have signs of repairs. Recommend asking the current homeowner for more information. Recommend further evaluation from a qualified contractor should the repairs be excessive or of visibly poor quality.

5.2.2 – Ceilings & Walls

Ceilings & Walls 3

Ceilings & Walls 4

Ceilings & Walls 5

SIGNS OF REPAIR-WALLS

The interior walls have signs of repairs. Recommend asking the current homeowner for more information. Recommend further evaluation from a qualified contractor should the repairs be excessive or of visibly poor quality.

5.3.1 – Floors

Floors 1

Floors 2

CARPET REVEALED A SEEM

The carpet revealed a seam.  A qualified contractor should evaluate and repair or replace as necessary.

5.3.2 – Floors
Floors 3
WEAR AND TEAR
THROUGHOUT PROPERTY

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Doors

Doors 1

MISSING – DOOR

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Windows

Windows 1

LOCK NOT WORKING

The window did not lock properly.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Windows
WORN OR NEARING THE END OF LIFE EXPECTANCY
ALUMINUM FRAME WINDOWS NEARING THE END OF THEIR LIFE ARE NOT AS ENERGY EFFICIENT AS CURRENT STANDARDS

Windows installed in the home appeared to be worn or aged. This apparent condition can mean the windows are deteriorated or difficult to operate, and can also mean they are not consistent with current efficiency standards. They were possibly original and were either at or near their serviceable lifespan. Recommend further evaluation by a qualified contractor and budgeting for potential future replacement.

5.5.3 – Windows

Windows 2

SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

5.6.1 – Electrical Outlets

Electrical Outlets 1

LOOSE – FACEPLATE

An electrical outlet had a loose faceplate. A qualified contractor should evaluate and repair or replace as necessary.

5.6.2 – Electrical Outlets

Electrical Outlets 2

MISSING – FACEPLATE

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

5.6.3 – Electrical Outlets

Electrical Outlets 3

NO GFCI PROTECTION – FIRST FLOOR BALCONY
BALCONY OUTLET MISSING SCREW CAP AT FLOOR

No ground fault circuit interrupter (GFCI) protection was provided for electrical outlets near the First floor balcony  Although GFCI protection exterior balcony area circuits may not have been required at the time of in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing bathroom electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFC I breaker.

A qualified contractor should evaluate and repair or replace as necessary.

5.8.1 – Stairways & Railings
Stairways & Railings 1

Stairways & Railings 2

Stairways & Railings 3
LOOSE – HANDRAIL

At the interior stairs, the handrail was loose.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

5.8.2 – Stairways & Railings
Stairways & Railings 4
MISSING – HANDRAIL

At the interior stairs, the handrail was missing.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

5.8.3 – Stairways & Railings

Stairways & Railings 5

Stairways & Railings 6

NOT INSTALLED PROPERLY

At the interior stairs, the steps were not installed on a satisfactory and safe manor.  A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary.

5.10.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
SMOKE DETECTOR MISSING
1ST FLOOR KITCHEN

The smoke detector was missing. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

5.12.1 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
CLEANING NEEDED

The visible areas of the firebox and chimney flue were dirty at the time of the inspection. Most of the chimney flue was inaccessible and was not inspected. Dirty flues are potential fire hazards and should be cleaned by a professional. Recommend having the chimney evaluated by a C.S.I. (Chimney Safety Institute) -qualified chimney sweep.

5.12.2 – Fireplace Wood-Burning
Fireplace Wood-Burning 2
DEFECT AT GLASS DOORS AT FIREPLACE
PAY DIFFICULT TO CLOSE

The fireplace had a defect at the glass doors. A qualified contractor should evaluate and repair or replace as necessary.

 6 – Kitchen
6.3.1 – Ceilings & Walls
Ceilings & Walls 1
ASBESTOS CEILING
POPCORN CEILING POSSIBLY CONTAINS ASBESTOS

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

6.3.2 – Ceilings & Walls
Ceilings & Walls 2
DAMAGED – BASEBOARD TRIM

Baseboard trim was damaged at areas of the interior walls at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

6.4.1 – Floors
Floors 1
WEAR AND TEAR

The floors showed signs of minor damage and wear – particularly in high traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.2 – Cabinets & Counters
Cabinets & Counters 2
LOOSE – HINGE

The cabinet hinge was loose and not securely fastened.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.3 – Cabinets & Counters
Cabinets & Counters 3
WORN FINISH

Counters or cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

6.6.1 – Electrical Outlets
Electrical Outlets 1
GFCI-NOT ALL PROTECTED

Ground fault circuit interrupter (GFCI) Protection was not provided for all kitchen electrical outlets. Although GFCI protection of kitchen outlets may not have been required at the time in which this property was built, as general knowledge of say fielding practices has improved with the passage of time building standards have changed to reflect current understanding.  A qualified contractor should evaluate and repair or replace as necessary.

6.7.1 – Windows
WONT STAY OPEN
KITCHEN

A window sash would not stay open at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

6.9.1 – Faucets Fixtures
Faucets Fixtures 1
FAUCET FINISH DAMAGED
KITCHEN

The finish on the faucet is damaged.  A qualified contractor should evaluate and repair or replace as necessary.

 7 – Laundry
7.9.1 – Electrical Outlets
GFCI PROTECTION NOT PRESENT
LAUNDRY AREA

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

 8 – Bathroom
8.3.1 – Exhaust Fan
Exhaust Fan 1
WEAK
2ND FLOOR BATHROOM

The bathroom exhaust fan was weak. A qualified contractor should evaluate and repair or replace as necessary.

8.4.1 – Ceilings & Walls

Ceilings & Walls 1

PAINT PEELING

The paint was peeling in areas.  A qualified contractor should evaluate and repair or replace as necessary.

8.4.2 – Ceilings & Walls
Ceilings & Walls 2
SIGNS OF REPAIR-CEILINGS
2ND FLOOR BATHROOM

The ceilings had signs of previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

8.5.1 – Floors
Floors 1
FLOOR NOT SEALED AT EDGE
2ND FLOOR BATHROOM

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

8.5.2 – Floors
Floors 2
SEAMS WIDE/INCONSISTENT

The flooring had seams that were wide or inconsistent possibly indication loose flooring or poor installation.  A qualified contractor should evaluate and repair or replace as necessary.

8.7.1 – Electrical Outlets
Electrical Outlets 1
DID NOT TRIP – GFCI OUTLET
2ND FLOOR BATHROOM

A GFCI outlet was defective (did not trip when tested). A qualified contractor should evaluate and repair or replace as necessary.

8.8.1 – Electrical Fixtures & Switches

Electrical Fixtures & Switches 1

DAMAGED – SWITCH

The switch was damaged. A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – COUNTER TOP
2ND FLOOR BATHROOM

The counter top was damaged at the time of the inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

8.9.2 – Cabinets & Counters
Cabinets & Counters 2
Cabinets & Counters 3
LOOSE – FACING

The counter top had facing that was loose in some areas.  A qualified contractor should evaluate and repair or replace as necessary.

8.9.3 – Cabinets & Counters
Cabinets & Counters 4
WORN FINISH

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

8.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
MISSING – TUB DRAIN STOPPER
2ND FLOOR BATHROOM

The bathtub drain stop was damaged, missing or did not operate properly.  A qualified contractor should evaluate and repair or replace as necessary.

8.12.1 – Plumbing Fixtures
LOOSE IN WALL – CONTROL VALVE
2ND FLOOR BATHROOM

A control valve was loose in the wall. This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

8.12.2 – Plumbing Fixtures
LOOSE IN WALL – TUB SPOUT
2ND FLOOR BATHROOM

The tub spout was loose in the wall. This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

8.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – CORNERS AND FLOOR

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

8.14.2 – Tub, Shower Area
Tub, Shower Area 2
CAULK – TUB TOP

The tub/shower area had deteriorated or missing sealant (caulking or grout) where the shower wall rests on the tub and/or at the inside corners. A qualified contractor should evaluate and repair or replace as necessary.

8.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT
2ND FLOOR

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

 9 – Bathroom 2
9.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED
1ST FLOOR BEDROOM

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

9.5.1 – Floors
Floors 1
FLOOR NOT SEALED AT EDGE
1ST FLOOR BATHROOM

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

9.9.1 – Cabinets & Counters
Cabinets & Counters 1
WORN FINISH

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

9.13.1 – Toilets
Toilets 1
FLUSH-SLOW TO FILL
1ST FLOOR BATHROOM WATER NOT FILLING AT ALL

The toilet was slow to fill when flushed.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 
10.2.1 – Doors
Doors 1
RUBS FRAME
BASEMENT BATHROOM

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

10.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED
BASEMENT BATHROOM

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

10.4.1 – Ceilings & Walls

Ceilings & Walls 1

MOISTURE DAMAGE-CEILINGS
BASEMENT BATHROOM

The ceilings showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

10.4.2 – Ceilings & Walls
Ceilings & Walls 2
SIGNS OF REPAIR-WALLS
BASEMENT BATHROOM

The walls had signs of a previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

10.5.1 – Floors
Floors 1
FLOOR NOT SEALED AT EDGE
BASEMENT BATHROOM

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

10.5.2 – Floors

Floors 2

SEAMS WIDE/INCONSISTENT
BASEMENT BATHROOM

The flooring had seams that were wide or inconsistent possibly indication loose flooring or poor installation.  A qualified contractor should evaluate and repair or replace as necessary.

10.7.1 – Electrical Outlets
Electrical Outlets 1
NO GFCI PROTECTION
BASEMENT BATHROOM

No ground fault circuit interrupter (GFCI) protection was provided for the bathroom electrical outlets. Although GFCI protection of bathroom circuits may not have been required at the time of in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing bathroom electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary.

10.9.1 – Cabinets & Counters
Cabinets & Counters 1
SIGNS OF REPAIR
CABINETS PAINTED OVER

The cabinetry had signs of previous repair.  A qualified contractor should evaluate and repair or replace as necessary.

10.9.2 – Cabinets & Counters
 Cabinets & Counters 2
WORN FINISH

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

10.10.1 – Drain Waste and Vent System

Drain Waste and Vent System 1

CLOGGED/SLOW – SINK DRAIN

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

10.12.1 – Plumbing Fixtures
LOOSE IN WALL – SHOWER ARM

A shower supply arm was loose in the wall.  This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

10.13.1 – Toilets
LOOSE AT THE FLOOR
BASEMENT BATHROOM

The toilet was loose at the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. Loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

10.13.2 – Toilets
Toilets 1
LOOSE-TOILET TO TANK
BASEMENT BATHROOM

The toilet was loose at the tank to toilet connection.  A qualified contractor should evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
SEALANT – MULTIPLE AREAS

Some caulking and/or grout in the tub & shower area was missing, loose, old, or poorly done.  Recommend a qualified contractor evaluate and re-seal as needed.

 11 – Electrical
11.1.1 – Electric Meter & Base
Electric Meter & Base 1
METER BASE NOT SECURE

The electric meter base was loose at time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Plumbing
12.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
MISSING HANDLE AT HOSE BIB
FRONT

The hose Spicket at the front of the home was missing its handle. suggest a qualified contractor repair or replace as necessary.

dismissing handle will prohibit water pressure inspection.

 14 – Water Heating Equipment
14.1.1 – General Information
General Information 1
WATER HEATER IN BEDROOM CLOSET

You’re was located in the basement front bedroom closet. verifying with qualified contractor weather having the water heater in an clothes closet in the bedroom is an acceptable use of the room.

14.6.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

14.11.1 – Burn Chamber
Burn Chamber 1
Burn Chamber 2
RUST CORROSION

The water heater burn chamber had rust/corrosion visible. A qualified contractor should evaluate and repair or replace as necessary.

14.12.1 – Operation & Response to Controls
Operation & Response to Controls 1
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

14.13.1 – Water Temperature
Water Temperature 1
Water Temperature 2
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

 15 – Cooling
15.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL
SLIGHTLY OUT OF LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 16 – Heating
16.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

16.12.1 – Heating System Ignition & Operation
SHORT CYCLING

The furnace was short-cycling (repeated start-up and shut-down within minutes of each other) at the time of the inspection. Most systems should run about 2-3 cycles per hour. A qualified contractor should evaluate and repair or replace as necessary.

16.12.2 – Heating System Ignition & Operation
Heating System Ignition & Operation 1
DIRTY

The heating system did fire and appeared to be in serviceable condition at the time of the inspection. However, the interior of the cabinet was dirty. Cleaning, servicing and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.