2 – Roof
2.8.1 – Roof Drainage Systems
Roof Drainage Systems 1
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.5.1 – Eaves, Soffits & Fascia

Eaves, Soffits & Fascia 1

DAMAGE – FASCIA

The fascia was damaged in one or more areas.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.10.1 – Window Wells
Window Wells 1
Window Wells 2
WINDOW WELL RUSTED

Window well(s) were rusted or corroded in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Floor
Floor 1
CRACKING – COMMON

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor evaluate and repair or replace as needed.

5.6.1 – Door Opener
Door Opener 1
MISSING – REVERSE SENSORS

The automatic reverse sensors are missing.

These are a safety feature to prevent injury, and should be installed no more than 6 inches away from the floor.

 6 – Interior, Doors, Windows
6.5.1 – Windows
Windows 1
Windows 2
BROKEN SEALS

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass was observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.2 – Windows

Windows 3

DAMAGED FRAME

A window had a damaged frame at an interior area.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.3 – Windows

Windows 4

Windows 5

Windows 6

SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Stairways & Railings
Stairways & Railings 1
NO RETURN AT ENDS

At the interior stairs, the handrail had a railing end that did not return to the wall or post.  A fall could occur if something (purse, backpack etc.) caught the end of the railing when descending. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.4.1 – Exhaust Fan
NO VENT NO WINDOW

The laundry room did not have an exhaust fan or an openable window. A qualified contractor should evaluate, then repair or replace as advised.

8.11.1 – Dryer Vent Piping
Dryer Vent Piping 1
KINKED/DAMAGED

A dyer vent connection was installed in the laundry area. The dryer vent was kinked and/or damaged at the back of the dryer.  The inspector recommends repair or replacing the dryer vent to prevent restricting dryer exhaust air flow, the restriction of which can result in lint accumulation or vent blockage which can cause the dryer to overheat; a potential fire hazard and a condition which will shorten the dryers life span. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CHIPPED – SINK

The sink finish was chipped or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 4
12.4.1 – Ceilings & Walls
Ceilings & Walls 1
DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

 14 – Electrical
14.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too.

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

14.2.2 – Distribution Panels
Distribution Panels 2
MISSING – MANUFACTURERS LABEL

The manufacturer’s label was missing, partial, or illegible at the  electrical service panel. The manufacturer’s label typically provides information describing the main panel such as the name of the panel manufacturer, the panel model number, the panel amperage rating, limitations related to the environment in which the panel was designed to be installed and grounding/bonding information for that particular model. The Inspector was unable to confirm the existence of proper conditions when confirmation would require information taken from this missing label.

14.6.1 – Electrical Wiring
Electrical Wiring 1
CUT CONDUCTORS

The inspector observed conductors that were cut to fit the circuit breaker. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

 15 – Water Heating Equipment
15.1.1 – General Information
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

15.12.1 – Operation & Response to Controls
Operation & Response to Controls 1
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

15.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

 16 – Heating
16.7.1 – Condensate
Condensate 1
SECONDARY

The secondary drain line was capped, missing or not routed to a drain. If the primary drain line becomes blocked, this condition could cause condensation to not drain properly and possibly damage the unit. The inspector recommends installing a secondary drain or installing an over flow protection device. A qualified contractor should evaluate then repair or replace as advised.

 18 – Cooling
18.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

18.3.2 – AC Compressor
AC Compressor 2
INADEQUATE CLEARANCE – RESTRICTED AIR FLOW

The air conditioner unit did not have proper clearance and the air flow was likely restricted. This may result in inefficient operation.

18.4.1 – AC Service Disconnect
AC Service Disconnect 1
EXPOSED TERMINALS

The service disconnect for the air conditioner was an older style and had exposed terminals underneath the cover of the disconnect. This could be a potential shock/safety hazard. A qualified contractor should evaluate and repair or replace as necessary.

 20 – Electric & Magnetic Fields (EMF)
20.1.1 – Electric Meter
Electric Meter 1
Electric Meter 2
UNACCEPTABLE RANGE

EMF testing at the electric meter showed elevated levels above 2.0 mGauss.

20.2.1 – Main Distribution Panel
Main Distribution Panel 1
Main Distribution Panel 2
UNACCEPTABLE RANGE

EMF testing at the main distribution panel showed elevated levels above 2.0 mGauss.

20.3.1 – Power Lines
Power Lines 1
UNACCEPTABLE RANGE

EMF testing of the near by power lines showed elevated levels above 2.0 mGauss.

20.4.1 – Front Door
Front Door 1
UNACCEPTABLE RANGE

EMF testing at the front door showed elevated levels above 2.0 mGauss.

20.5.1 – Back Door
Back Door 1
UNACCEPTABLE RANGE

EMF testing at the back door showed elevated levels above 2.0 mGauss.

20.6.1 – Interior Rooms

Interior Rooms 1

Interior Rooms 2

Interior Rooms 3

UNACCEPTABLE RANGE

EMF testing at the interior rooms showed elevated levels above 2.0 mGauss.

20.7.1 – Interior Wall At Electrical Service
Interior Wall At Electrical Service 1
UNACCEPTABLE RANGE

EMF testing at the interior wall opposite the electrical panel/meter showed elevated levels above 2.0 mGauss.

20.8.1 – Microwave
Microwave 1
Microwave 2
UNACCEPTABLE RANGE

EMF testing at the microwave showed elevated levels above 2.0 mGauss.

20.9.1 – Range
Range 1
Range 2
UNACCEPTABLE RANGE
EMF testing at the range showed elevated levels above 2.0 mGauss.