The vent flashing, used to protect areas of the roof from moisture intrusion, had exposed/inadequately sealed nails. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.
Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.
Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.
A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The insulation is not uniform: thicker in areas, thinner in areas, or possibly missing in some areas.
Recommend a qualified contractor evaluate and repair or replace as needed.
Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.
Dense vegetation was present around the house in areas. This condition limited and restricted my visual inspection. Dense vegetation and landscaping up against or near the house foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning and some landscaping is recommended by a qualified contractor
The outside water faucet is in place but no longer connected to plumbing (inoperable.) A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The guard/hand rail had horizontal railings. This creates a climbing risk and a fall or injury could occur if not corrected. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.
One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.
Recommend a qualified contractor evaluate and repair or replace as necessary.
The garage door panelling was dented, corroded, or damaged and should be further evaluated by a qualified contractor to repair or replace as needed.
Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the garage electrical outlets. A qualified contractor should evaluate and implement according to current standards.
Although GFCI protection of garage circuits may not have been required at the time in which this property was built, GFCI protection is now required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage.
The door had a damaged or missing doorstop. A qualified contractor should evaluate and repair or replace as necessary.
Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.
There are no carbon monoxide detectors on the lower or upper level.
Caulking at the bathroom counter area was a poor installation, or had areas in poor condition and needs a touch-up. Recommend a qualified contractor evaluate and repair or replace as needed
The main electrical shut-off switch was not accessible. Recommend a qualified contractor evaluate and repair or replace as needed.
The expansion tank was not properly secured. A qualified contractor should evaluate and repair or replace as necessary.
The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
Surface and/or interior components of the AC condenser showed rust in areas. Recommend a qualified contractor evaluate, service, and repair or replace as necessary.
The crawl space insulation was damaged. A qualified contractor should evaluate and repair or replace as necessary.
The basement insulation was damaged. A qualified contractor should evaluate and repair or replace as necessary.
The outlets in the unfinished basement were not all GFCI protected. GFCI protection is required for all 15- and 20-amp, 120-volt receptacles in the unfinished basement. NEC 210.8(A)(5). A qualified contractor should evaluate and repair as necessary.