2 – Roof
2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 4 – Exterior
4.8.1 – Electrical Outlets
LOOSE OUTLET
BACK

An exterior electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways
Walkways 1
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.2 – Walkways
Walkways 2
Walkways 3
CRACKING – SIGNIFICANT

There were signs of significant cracking on the walkway(s) in areas. Cracks that with a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. These cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

4.11.3 – Walkways
Walkways 4
DETERIORATED
RIGHT

The walkway(s) were deteriorated or were eroded in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
DENSE VEGETATION

Dense vegetation was present around the house in areas.  This condition limited and restricted my visual inspection.  Dense vegetation and landscaping up against or near the house foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning, and some landscaping are recommended by a qualified contractor

4.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
Vegetation, Grading & Drainage 3
Vegetation, Grading & Drainage 4
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
Roof Drainage - Downspouts & Extensions 2
MISSING – EXTENSIONS
RIGHT AND LEFT

The downspout (s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 5 – Interior, Doors, Windows
5.3.1 – Floors
Floors 1
SLOPED
LIVING ROOM DINING ROOM

The floor has a dip or is sloped in areas.

Recommend a qualified contractor to evaluate and repair or replace as needed.

5.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
SMOKE DETECTOR MISSING
PRIMARY BEDROOM

The smoke detector was missing. A qualified person should replace them as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

 7 – Detached Garage 
7.4.1 – Ceiling & Walls in Garage
Ceiling & Walls in Garage 1
DEFECT – CEILING

A defect in the ceiling was present in the detached garage.

Recommend a qualified contractor to evaluate and repair or replace as needed.

7.5.1 – Floor
Floor 1
CRACKED – COMMON

The concrete floor in the garage was cracked.

A qualified contractor should evaluate and repair as necessary.

7.7.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

7.8.1 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 1
MISSING – COVER PLATE

An outlet in the detached garage was missing a cover plate at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

7.8.2 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 2
NO GFCI PROTECTION

The garage had one or more outlets without GFCI (or ground fault circuit interrupter) protection.

GFCI protection is required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage. A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Windows
Windows 1
CRACKED-GLASS WINDOWPANE

A window had cracked glass or windowpane.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

7.9.2 – Windows
Windows 2
Windows 3
Windows 4
NEARING THE END OF LIFE

A window showing signs of nearing end-of-life. Recommend a qualified contractor for reevaluation repair as necessary.

 8 – Laundry
8.2.1 – Doors
Doors 1
NOT CLOSING TIGHT

The door needs a strike plate adjustment to close tightly.

8.4.1 – Exhaust Fan
Exhaust Fan 1
NO VENT NO WINDOW

The laundry room did not have an exhaust fan or an openable window. A qualified contractor should evaluate, then repair or replace as advised.

 9 – Bathroom
9.3.1 – Exhaust Fan
Exhaust Fan 2
NOT INSTALLED PROPERLY

An exhaust fan in the bathroom was not installed properly at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

9.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
INOPERABLE – LIGHT

The light fixture did not operate when the switch was turned on. Try replacing the bulb first. A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
LOOSE IN WALL – SHOWER ARM

A shower supply arm was loose in the wall.  This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

 10 – Bathroom 2
10.3.1 – Exhaust Fan
Exhaust Fan 1
NOT INSTALLED PROPERLY

An exhaust fan in the bathroom was not installed properly at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

 11 – Bathroom 3
11.3.1 – Exhaust Fan
Exhaust Fan 2
NOT INSTALLED PROPERLY

An exhaust fan in the bathroom was not installed properly at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

 14 – Water Heating Equipment
14.11.1 – Burn Chamber
Burn Chamber 1
MISSING COVER

The burn chamber cover was missing. This is a safety hazard. Recommend a qualified contractor evaluate further and repair or replace as needed.

14.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

 16 – Cooling
16.3.1 – AC Compressor
 AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings, and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16.4.1 – AC Service Disconnect
AC Service Disconnect 1
AC Service Disconnect 2
INCORRECT BREAKER RATING

The circuit breaker was rated higher than the capacity listed on the compressor’s manufacture label. This condition could damage the unit or possibly start an electrical fire. Recommend having a qualified contractor repair or replace as necessary.

16.6.1 – Cooling System Operation
Cooling System Operation 1
Cooling System Operation 2
DID NOT PRODUCE COOLED AIR

The cooling system turned on but did not operate as expected by producing adequately conditioned cooled air. An ambient air test was performed to determine if the difference in temperatures of the supply and return air was between 14 degrees and 22 degrees. A qualified contractor should evaluate and repair/replace as necessary.

 19 – Structural Crawlspace
19.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
Soil Vapor Barrier 2
BARRIER DAMAGED

The crawlspace vapor barrier was damaged in some areas, which compromises its effectiveness in reducing moisture and/or radon levels. A qualified contractor should evaluate and repair or replace as necessary.

19.7.1 – Ventilation
Ventilation 1
NEEDED – PASSIVE VENTS

There were no passive vents installed for the crawlspace at the time of inspection. If a crawlspace is not a conditioned air space, it is recommended to have passive vents in order to maintain satisfactory heat and humidity levels.