2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
BULGING/BUBBLING
ROOF

The roof covering is bulged or bubbled in some areas, which may make it more susceptible to damage.  A qualified contractor should evaluate and repair or replace as necessary.

2.2.2 – Roof Covering
Roof Covering 3
Roof Covering 4
Roof Covering 5
DAMAGE/EROSION
ROOF

The roof covering material has moderate damage or erosion in several areas. A qualified contractor should evaluate and repair or replace as necessary.

2.2.3 – Roof Covering
Roof Covering 6
Roof Covering 7
Roof Covering 8
PATCHED AND SEALED
ROOF

The roof covering material shows signs of previous patches and sealing at multiple areas. A qualified contractor should evaluate and repair or replace as necessary.

2.3.1 – Flashing
Flashing 1
Flashing 2
WALL FLASHING DAMAGED
ROOF

Wall flashing was corroded/damaged in areas. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

2.3.2 – Flashing
Flashing 3
WALL FLASHING IMPROPERLY SEALED
ROOF

Wall flashing appears to be improperly sealed. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

2.4.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
BENT/DAMAGED
GUTTERS

Gutters were bent and/or damaged at the time of the inspection. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.4.2 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
CORROSION – MODERATE
GUTTERS

Gutters had moderate general corrosion visible. Corrosion is generally a sign of poor sloping or drainage, and continued corrosion will eventually result in leaking gutters. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. A qualified contractor should evaluate and repair or replace as necessary.

2.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
DENTED OR DAMAGED – CAP
EXHAUST FLUE

A flue pipe cap is excessively dented or damaged. A qualified contractor should evaluate and repair or replace as necessary.

2.6.2 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 2
Flue Gas Vent Pipes 3
LOOSE CAPS
BATHROOM VENTS

The bathroom vent caps were loose in areas on the roof. A qualified contractor should evaluate and repair or replace as necessary.

 3 – Exterior
3.2.1 – Walkways & Driveways
Walkways & Driveways 1
HEAVING AND/OR SETTLING
WALKWAYS

The driveway/walkway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3.2.2 – Walkways & Driveways
Walkways & Driveways 2
NOT SEALED PROPERLY
WALKWAYS

A walkway was not properly sealed against a foundation wall and may allow excess moisture to enter. A qualified contractor should evaluate and repair or replace as necessary.

3.2.3 – Walkways & Driveways
Walkways & Driveways 3
Walkways & Driveways 4
Walkways & Driveways 5
MODERATE CRACKING – PARKING LOT
PARKING LOT

There were signs of moderate cracking in the parking lot areas. A qualified contractor should evaluate and repair or replace as necessary.

3.2.4 – Walkways & Driveways
Walkways & Driveways 6
Walkways & Driveways 7
MODERATE CRACKING – WALKWAYS
WALKWAYS

There were signs of moderate cracking on the walkways in areas. A qualified contractor should evaluate and repair or replace as necessary.

3.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
CRACKING AND MOVEMENT
EXTERIOR

Cracking as well as movement was present on the siding at the time of inspection.

Monitoring the masonry walls of the house is needed. Although masonry can deform elastically over long periods of time to accommodate small amounts of movement, large movements normally cause cracking.

Cracking can result from a variety of problems:

  • Differential settlement of the foundation
  • Drying shrinkage
  • Expansion and contraction due to ambient thermal and moisture variations
  • Improper support over openings
  • The effects of freeze-thaw cycles
  • The corrosion of iron and steel wall reinforcement
  • Differential movement between building materials; expansion of salts
  • The bulging or leaning of walls.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
Wall-Covering, Flashing & Trim 5
CRACKING – MINOR
EXTERIOR

Siding showed cracking in one or more places around the property. A qualified contractor should evaluate and repair or replace as necessary.

3.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 6
PENETRATIONS
EXTERIOR

There were penetrations in areas of the siding at the time of inspection. Recommend applying the appropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.

3.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 7
Wall-Covering, Flashing & Trim 8
Wall-Covering, Flashing & Trim 9
DETERIORATION
EXTERIOR

The exterior wall covering is beginning to deteriorate or has deteriorated in multiple areas. A qualified contractor should evaluate and repair or replace as necessary.

3.4.5 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 10
Wall-Covering, Flashing & Trim 11
Wall-Covering, Flashing & Trim 12
PEELING PAINT
EXTERIOR

Peeling paint was present in areas of the exterior. A qualified contractor should evaluate and repair or replace as necessary.

3.4.6 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 13
Wall-Covering, Flashing & Trim 14
SIGNS OF REPAIRED DAMAGE
EXTERIOR

There were signs of previously repaired damage on the exterior.  A qualified contractor should evaluate and repair or replace as necessary.

3.5.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
DENSE VEGETATION
EXTERIOR

Dense vegetation was present around the unit in areas.  This condition limited and restricted my visual inspection.  Dense vegetation and landscaping up against or near the unit’s foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning, and some landscaping are recommended by a qualified contractor

3.5.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
TREE BRANCHES OVER PROPERTY
EXTERIOR

Large trees near the building have branches that overhang the property. Falling branches due to conditions such as wood decay, high winds, or heavy snow loads may cause injury, death, or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection. A qualified contractor should evaluate and repair or replace as necessary.

3.6.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
MOISTURE DAMAGE
EAVES

Components of the eaves, facia, and/or soffit were warped, swollen, or had peeling paint which are signs of water damage. The materials will eventually begin to rot if left untreated or cause has not been corrected. A qualified contractor should evaluate and repair or replace as necessary.

3.6.2 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 2
Eaves, Soffits & Fascia 3
Eaves, Soffits & Fascia 4
EAVES-PEELING PAINT
EAVES

The paint was peeling or cracking in one or more areas of the eaves. A qualified contractor should evaluate and repair or replace as necessary.

3.7.1 – Exterior Doors
Exterior Doors 1
BROKEN/CRACKED GLASS
FRONT DOOR

The front entry door had a broken or cracked glass pane.  A qualified contractor should evaluate and repair or replace as necessary.

3.7.2 – Exterior Doors
Exterior Doors 2
DAMAGE – DOOR
REAR ENTRANCE

The surface of the exterior rear door was corroded/damaged or in poor condition. A qualified contractor should evaluate and repair or replace as necessary.

3.8.1 – Electrical Fixtures
Electrical Fixtures 1
Electrical Fixtures 2
Electrical Fixtures 3
DEFECT – ELECTRICAL
EXTERIOR

There were multiple areas of exposed wires not enclosed in junction boxes with covers on the exterior. A qualified contractor should evaluate and repair or replace as necessary.

3.8.2 – Electrical Fixtures
Electrical Fixtures 4
MISSING OR BROKEN BULB
EXTERIOR

An exterior light fixture had missing or burnt-out bulb(s). The bulb(s) should be replaced, and if still inoperable, a qualified contractor should evaluate and make necessary changes.

3.10.1 – Windows
Windows 1
WOOD ROT AT WINDOW
EXTERIOR

An exterior window has trim or framing that appears to have wood rot. This may represent a general lack of maintenance or potential water intrusion issues. A qualified contractor should evaluate and repair or replace as necessary.

3.13.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
MISSING – HANDLE KNOB
EXTERIOR

The outside water faucet was missing a handle/knob. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3.20.1 – Roof Drainage System – Downspouts & Extensions
Roof Drainage System - Downspouts & Extensions 1
MISSING – DOWNSPOUT
EXTERIOR

Downspouts were missing in areas of the property. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation.  A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3.20.2 – Roof Drainage System – Downspouts & Extensions
Roof Drainage System - Downspouts & Extensions 2
MISSING – EXTENSIONS
EXTERIOR

The downspout (s) are missing extensions in areas. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 4 – Attic, Insulation & Ventilation
4.4.1 – Insulation in Attic
Insulation in Attic 1
MISSING – INSULATION
ATTIC

The insulation is missing in the attic area. A qualified contractor should evaluate and repair or replace as necessary.

4.6.1 – Electrical Wiring In Attic
Electrical Wiring In Attic 1
JUNCTION BOX MISSING COVER PLATE
ATTIC

Splice/Junction boxes were missing cover plates in the attic area. A qualified contractor should evaluate and repair or replace as necessary.

 5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls
Ceilings & Walls 1
ASBESTOS CEILING
INTERIOR

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn textures were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, are generally considered non-friable and not hazardous. Heat, water, weathering, or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized, or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized, or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

5.2.2 – Ceilings & Walls
Ceilings & Walls 2
Ceilings & Walls 3
Ceilings & Walls 4
DAMAGED – CEILINGS
INTERIOR

The ceilings showed signs of damage and wear in several areas throughout the property.  A qualified contractor should evaluate and repair or replace as necessary.

5.2.3 – Ceilings & Walls
Ceilings & Walls 1
Ceilings & Walls 2
Ceilings & Walls 3
DAMAGED – WALLS (MULTIPLE ISSUES)
INTERIOR

The walls showed signs of damage, cracks, and/or previous repairs throughout the property.  A qualified contractor should evaluate and repair or replace as necessary.

5.2.4 – Ceilings & Walls
Ceilings & Walls4
SIGNS OF REPAIR-CEILINGS
INTERIOR

The ceilings had signs of the previous repair in areas.  A qualified contractor should evaluate and repair or replace as necessary.

5.2.5 – Ceilings & Walls
Ceilings & Walls 5
Ceilings & Walls 6
BROKEN MIRRORS
INTERIOR

Several interior mirrors were cracked/damaged in areas. A qualified contractor should evaluate and repair or replace as necessary.

5.3.1 – Floors
Floors 1
ASBESTOS TILES
INTERIOR

The property had tiles that may contain asbestos. A qualified contractor should evaluate and repair or replace as necessary. Flooring, including sheet vinyl, vinyl, or asphalt floor tiles and any associated paper-like backing, mastic, adhesive, or glue, may contain asbestos. In the past, asbestos fibers were added during the production of flooring materials to strengthen the flooring and increase its durability. Flooring that contains asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering, or aging can weaken flooring to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized, or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized, or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

5.3.2 – Floors
Floors 2
Floors 3
CARPET STAINS-
INTERIOR

The carpet was stained in areas throughout the property. A qualified contractor should evaluate and repair or replace as necessary.

5.3.3 – Floors
Floors 4
Floors 5
CRACKED/DAMAGED TILES
INTERIOR

The tile floor was cracked/damaged in areas throughout the property.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Doors
Doors 1
GAP AROUND DOOR
REAR ENTRANCE DOOR

The rear entrance door had an opening that was too wide leaving a gap or daylight around the door.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.2 – Doors
Doors 2
Doors 3
STRIKES NOT LATCHING
BATHROOM DOORS

The bathroom doors would not latch when closed and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

5.6.1 – Electrical Outlets
Electrical Outlets1
DAMAGED – OUTLET
INTERIOR

Several electrical outlets were broken/damaged inside the property. A qualified contractor should evaluate and repair or replace as necessary.

5.6.2 – Electrical Outlets
Electrical Outlets 2
OUTLETS NOT ALL GFCI PROTECTED – BAR SINK
BAR SINKS

No ground fault circuit interrupter (GFCI) protection was provided for all of the electrical outlets near the bar sink. Although GFCI protection of sink area circuits may not have been required at the time of in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing bathroom electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFC I breaker.

A qualified contractor should evaluate and repair or replace as necessary.

5.6.3 – Electrical Outlets
Electrical Outlets 3
Electrical Outlets 4
NOT GROUNDED – OUTLETS
INTERIOR

One or more electrical outlets were not grounded throughout the property. A qualified contractor should evaluate and repair or replace as necessary.

5.6.4 – Electrical Outlets
Electrical Outlets 5
NOT WORKING – OUTLET
INTERIOR

An electrical outlet was not working near the stage area. A qualified contractor should evaluate and repair or replace as necessary.

5.6.5 – Electrical Outlets
Electrical Outlets 6
EXPOSED WIRES
INTERIOR

Outlet)s) had exposed or improper slices in areas inside the property. A qualified contractor should evaluate and repair or replace as necessary.

5.6.6 – Electrical Outlets
Electrical Outlets 7
Electrical Outlets 8
LOOSE CONDUIT
INTERIOR

Outlet(s) had loose/not properly secured conduit that can be damaged inadvertently. A qualified contractor should evaluate and repair or replace as necessary.

5.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
EXPOSED WIRING – LIGHT FIXTURE
INTERIOR

Light fixture(s) had exposed splices or electrical conductors in areas. A qualified contractor should evaluate and repair or replace as necessary.

5.7.2 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 2
Electrical Fixtures & Switches 3
Electrical Fixtures & Switches 4
INOPERABLE – LIGHT FIXTURES
MULTIPLE LIGHTS

Multiple light fixtures did not operate when the switch was turned on. A qualified contractor should evaluate and repair or replace as necessary.

5.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
INTERIOR

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that have a fuel-burning heater or appliance, a fireplace, or an attached garage.

5.9.2 – Smoke & CO Detectors
SMOKE DETECTOR MISSING
INTERIOR

The smoke detector was missing throughout the building. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

5.11.1 – Bar Sink
Bar Sink 1
Bar Sink 2
DAMAGED COUNTERTOPS
BAR SINK

The countertops in the bar area were warped and damaged in areas. A qualified contractor should evaluate and repair or replace as necessary.

 6 – Bathroom
6.2.1 – Exhaust Fan
Exhaust Fan 1
NOT WORKING
MEN’S BATHROOM

The bathroom exhaust fan did not work in the men’s bathroom.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH
MEN’S BATHROOM

The countertop needs caulking with silicone along the backsplash in the men’s bathroom.  A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Plumbing Fixtures
Plumbing Fixtures 1
CHIPPED – SINK
MEN’S BATHROOM

The sink finish was chipped or damaged in the men’s bathroom.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – HVAC Packaged Unit
8.1.1 – System Information
System Information 1
SERVICING RECOMMENDED
RTU

Due to the year of manufacture (2005), the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate and repair or replace as necessary.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

8.2.1 – Shut-Off Switch
Shut-Off Switch 1
Shut-Off Switch 2
DAMAGED ELECTRICAL CONDUCTORS
RTU

The HVAC electrical service shut-off switch for the heating system had exposed or damaged electrical conductors. A qualified contractor should evaluate and repair/replace as necessary.

8.6.1 – Cabinet
Cabinet 1
CORRODED, RUSTED, DIRTY
RTU

The heating system cabinet was corroded, rusted, or dirty/damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

8.6.2 – Cabinet
Cabinet 2
WASPS NEST
RTU

Wasps nests were noted in areas inside the rooftop heating unit. A qualified contractor should evaluate and repair or replace as necessary.

8.7.1 – Condensate
Condensate 1
DISCHARGE TOO SHORT
RTU

The condensate discharge pipe should be extended so that the water is diverted to a proper drain or to a proper distance away from the unit. A qualified contractor should evaluate and repair or replace as necessary.

8.8.1 – AC Compressor
AC Compressor 1
COIL FINS DAMAGED
RTU

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

8.16.1 – Heating System Ignition & Operation
Heating System Ignition & Operation 1
DIRTY
RTU

The heating system did fire and appeared to be in a serviceable condition at the time of the inspection. However, the interior of the cabinet was dirty. Cleaning, servicing, and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.

 9 – Cooling – Evaporative Cooler
9.2.1 – Cabinet, Reservoir, Drain Line
Cabinet, Reservoir, Drain Line 1
Cabinet, Reservoir, Drain Line 2
CORROSION
SWAMP COOLER

The reservoir appears to be corroded or rusted in areas. A qualified contractor should evaluate and repair or replace as necessary.

9.2.2 – Cabinet, Reservoir, Drain Line
Cabinet, Reservoir, Drain Line 3
MISSING DRAIN LINE
SWAMP COOLER

The evaporative cooler was missing a drain line. This may cause accelerated wear to the nearby roofing components. A qualified contractor should evaluate and repair or replace as necessary.

9.4.1 – Evaporative Pads, Filters
Evaporative Pads, Filters 1
EVAPORATIVE PADS – NEED REPLACEMENT
SWAMP COOLER

Recommend replacing the evaporative cooling pads on the swamp cooler and cleaning the reservoir. A qualified contractor should evaluate and repair or replace as necessary.

 11 – Electrical
11.3.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS
ELECTRICAL PANEL

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power to. Recommend a qualified contractor to verify the breakers and accuracy of any existing labeling as necessary.

11.3.2 – Distribution Panels
Distribution Panels 2
SCREWS MISSING – PANEL COVER
ELECTRICAL PANEL

Screws/fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

11.6.1 – Electrical Circuit Breakers
Electrical Circuit Breakers 1
Electrical Circuit Breakers 2
DOUBLE TAPPED BREAKERS
ELECTRICAL PANEL

One or more circuit breakers have two wires that are connected to a breaker designed for only one wire. This is known as a “double-tap” and is a defective condition. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Water Heating Equipment
12.2.1 – Water Shut-Off & Pipe Connections
Water Shut-Off & Pipe Connections 1
CORRODED – PIPE FITTINGS
WATER HEATER

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

12.5.1 – Combustion Air Supply
FRESH AIR-NOT PRESENT
WATER HEATER

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

The fresh air supply is recommended by manufacturers for the efficient operation of fuel-burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

12.7.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
OVER 6″ FROM FLOOR
WATER HEATER

The TPRV pipe did not conspicuously terminate within 6 inches of the floor. This may allow high-pressure hot water to cause unnecessary damage. A qualified contractor should evaluate and repair or replace as necessary.