2 – Attic, Insulation, and Ventilation
2.4.1 – Insulation in Attic
Insulation in Attic 1
Insulation in Attic 2
DEBRIS OVER THE INSULATION
ATTIC

There appeared to be debris, cardboard, plastic, wood, lint, etc. on the insulation. This configuration could lead to a possible mold environment and a fire hazard. The inspector recommends that it be removed.

2.7.1 – Exhaust System Vents
Exhaust System Vents 1
Exhaust System Vents 2
DRYER EXHAUSTS INTO ATTIC

The dryer vent duct terminated in the attic and did not vent to the exterior of the property. This may cause major moisture and mold issues and is also a fire hazard. All mechanical exhaust fans must terminate outside.

A qualified contractor should evaluate and repair or replace as needed.

 4 – Attached Garage
4.2.1 – Occupant Door
Occupant Door 1
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazards and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Floor
Floor 1
CRACKING – MINOR

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor to evaluate and repair or replace as needed.

4.5.1 – Vehicle Door
Vehicle Door 1
DAMAGE – PANELS

The garage door paneling was dented, corroded, or damaged and should be further evaluated by a qualified contractor to repair or replace it as needed.

4.6.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

4.7.1 – Electrical Outlets & Fixtures
Electrical Outlets & Fixtures 1
GFCI – NOT ALL PROTECTED

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the garage electrical outlets. A qualified contractor should evaluate and implement according to current standards.

Although GFCI protection of garage circuits may not have been required at the time in which this property was built, GFCI protection is now required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage.

 5 – Exterior – Condo/Townhome
5.2.1 – Exterior Vents
Exterior Vents 1
Exterior Vents 2
RADON EXHAUST

It appears that the radon exhaust vent is too close to a window, door, chimney, or other vents that may allow radon gases into the interior.

 6 – Interior, Doors, Windows
6.3.1 – Floors
Floors 1
WEAR AND TEAR

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.7.1 – Electrical Fixtures & Switches
FAN WOBBLES
PRIMARY BEDROOM

The ceiling fan wobbles when operated and may need to be balanced.  A qualified contractor should evaluate and repair or replace as necessary.

6.7.2 – Electrical Fixtures & Switches
DOORBELL INOP

Not working  doorbell

6.8.1 – Stairways & Railings
Stairways & Railings 1
STAIR SQUEAKS

The stair floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary.

 7 – Kitchen
7.12.1 – Food Waste Disposer
HUMS

The food waste disposer hums.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.5.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE STAINING-CEILINGS
LAUNDRY AREA

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.9.1 – Cabinets & Counters

Cabinets & Counters 1

CAULKING – BACKSPLASH

The countertop needs caulking with silicone along the backsplash.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
LEAK – SHOWER HEAD
PRIMARY CORNER

There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as necessary.

9.16.1 – Water Supply Functional Flow
PRESSURE DROP

With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.12.1 – Plumbing Fixtures
LEAK – SHOWER HEAD
ATTIC BATHROOM

There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as necessary.

 11 – Bathroom 3
11.7.1 – Electrical Outlets
Electrical Outlets 1
DAMAGED- FACE PLATE
1ST FLOOR BATHROOM

An electrical outlet had a damaged faceplate. A qualified contractor should evaluate and repair or replace as necessary.

11.13.1 – Toilets
LOOSE ON THE FLOOR
1ST FLOOR BATHROOM

The toilet was loose on the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. The loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

11.16.1 – Water Supply Functional Flow
PRESSURE DROP

With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 4
12.9.1 – Cabinets & Counters

Cabinets & Counters 1

CAULKING – BACKSPLASH

The countertop needs caulking with silicone along the backsplash.  A qualified contractor should evaluate and repair or replace as necessary.

12.10.1 – Drain Waste and Vent System

Drain Waste and Vent System 1

FLEX PIPE

Flexible drain lines can clog, leak, or fail. Flex lines design includes multiple folds in which moisture may become trapped and mold may grow.  A qualified contractor should evaluate and repair or replace as necessary.

12.16.1 – Water Supply Functional Flow
PRESSURE DROP

With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Plumbing
13.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
LEAKING – DISTRIBUTION LINE

The distribution piping runs from the main source to each faucet or fixture.

A water distribution pipe was leaking at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary.

13.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure is measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances are likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 14 – Electrical
14.2.1 – Distribution Panels
Distribution Panels 1
INADEQUATE WORKSPACE – PANEL

The distribution panel had inadequate clear space that is 3 feet deep, 30 inches wide, and 6′ 6″ in height in front of the equipment. A qualified contractor should evaluate and repair or replace as necessary.

14.2.2 – Distribution Panels
Distribution Panels 2
LOOSE – PANEL

The electrical panel cabinet was not secured to the wall properly. A qualified contractor should evaluate and repair or replace as necessary.

14.6.1 – Electrical Wiring
Electrical Wiring 1
Electrical Wiring 2
NO ACCESS – COULDN’T REMOVE COVER

The interior components could not be fully evaluated at the time of inspection – The cover could not be removed without dismantling breakers or filler plates. A qualified contractor should evaluate and repair or replace as necessary.

 15 – Water Heating Equipment
15.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

 16 – Heating
16.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.1.2 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

16.6.1 – Cabinet
Cabinet 1
Cabinet 2
CORRODED, RUSTED

The heating system cabinet was corroded, rusted, or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

 17 – Cooling
17.3.1 – AC Compressor
AC Compressor 1
AIR FLOW RESTRICTED

Airflow to the air-conditioner condenser coils was restricted by vegetation, dirt, or debris. The unit should be cleaned and anything restricting air flow in or around the air conditioner should be removed in order to maintain cooling system efficiency and avoid problems from overheating of the compressor.

17.3.2 – AC Compressor
AC Compressor 2
INADEQUATE CLEARANCE – RESTRICTED AIRFLOW

The air conditioner unit did not have proper clearance and the airflow was likely restricted. This may result in inefficient operation.