3 – Attic, Insulation, and Ventilation
3.2.1 – Attic Structural Components
Attic Structural Components 1
Attic Structural Components 2
LOOSE RAFTER SUPPORT

Rafter supports are not nailed in completely. Recommend a qualified contractor for reevaluation or repair as necessary.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
SIGNS OF REPAIRS

Signs of repairs were present on the driveway in areas. Recommend asking the current homeowner for more information, and if repairs appear to be of poor quality it is recommended to have a qualified contractor evaluate further for any additional repairs necessary.

 6 – Interior, Doors, Windows
6.5.1 – Windows
Windows1
Windows 2
Windows 3
WINDOWS INSTALLED IMPROPERLY
ONE OR MORE THROUGHOUT THE PROPERTY
 9 – Bathroom
9.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

The hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 2
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

The hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

 14 – Water Heating Equipment
14.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace it as necessary.