4 – Attached Garage
4.5.1 – Vehicle Door
Vehicle Door 1
DAMAGE – SPRING(S)

The garage door spring(s) was broken and in need of replacement. Garage door spring(s) are designed to assist the lifting of the door, and when the door is in the closed position they’re under extreme tension. Operating the door in this condition can cause serious injury or death, and is not advised.

 5 – Interior, Doors, Windows
5.3.1 – Floors
Floors 1
CARPET DAMAGED

The carpet was damaged in areas. A qualified contractor should evaluate and repair or replace as necessary.

5.3.2 – Floors
CARPET LOSE

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

5.3.3 – Floors
Floors 2
DAMAGED – FLOOR COVERING

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor to evaluate and repair or replace as needed.

5.3.4 – Floors
Floors 3
NOT PROPERLY INSTALLED

The flooring was not installed according to professional standards.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Doors
Doors 1
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Windows
Windows 1
DAMAGED SILL

The window had a sill and/or surround that was damaged. A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Windows
Windows 2
Windows 3
SEALANT DAMAGED AROUND FRAME

The sealant was damaged and deteriorated around the window. Recommend a qualified contractor to repair or replace as necessary.

5.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
Electrical Fixtures & Switches 2
NOT WORKING – BULB(S)

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

 9 – Bathroom
9.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE STAINING-CEILINGS

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
NOT WORKING – SINK STOPPER

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
WATER NOT DIVERTED

The shower diverter did not divert all of the water to the shower and a stream of water passed through the bathtub spout when the shower was on.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.2.1 – Doors

Doors 1

MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

10.4.1 – Ceilings & Walls

Ceilings & Walls 1

DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
SCREWS MISSING – PANEL COVER

Screws/fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

EDIT

 13 – Water Heating Equipment
13.1.1 – General Information
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

 14 – Heating
14.7.1 – Condensate
Condensate 1
SIGNS OF LEAKING

The condensation drain components for the HVAC system were leaking or showing signs of the previous leaking. A qualified contractor should evaluate and repair or replace as necessary.

14.8.1 – Ductwork
Ductwork 1
DUCTS NOT SEALED

Air supply ducts were not sealed. Ideally, all ducts are sealed with mastic in order to be more energy-efficient. A qualified contractor should evaluate and repair as necessary.

14.10.1 – Blower
Blower 1
BLOWER WHEEL DIRTY

The blower motor and/or wheel appeared to be dirty at the time of inspection. Blower fan motors and fan wheels are subjected to constant dirt, dust, and lint and can become overly dirty when not cleaned on a regular basis and even faster if the air filters are not changed regularly.

A qualified contractor should evaluate, clean, and service as necessary, and certify the unit is in good working order.

14.12.1 – Heating System Ignition & Operation
EXHAUST FAN

The exhaust fan appeared to be noisy at startup.

 15 – Cooling
15.1.1 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

15.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
GAP AROUND LINE AT WALL

The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.

15.3.1 – AC Compressor
AC Compressor 1
AIR FLOW RESTRICTED

Airflow to the air-conditioner condenser coils was restricted by vegetation, dirt, or debris. The unit should be cleaned and anything restricting air flow in or around the air conditioner should be removed in order to maintain cooling system efficiency and avoid problems from overheating of the compressor.