2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
Roof Covering 3
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
TOO SHORT

A plumbing vent did not extend far enough above the roof. A plumbing vent should extend a minimum of 10″.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MODERATE

The concrete driveway was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

4.2.2 – Driveways
Driveways 2
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
TREE BRANCHES OVER PROPERTY

Large trees near the house have branches which overhang the property. Falling branches due to conditions such as wood decay, high winds or heavy snow loads may cause injury, death or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.18.1 – Exterior Vents
Exterior Vents 1
MISSING COVER/FLAP
RIGHT

The vent was missing a proper cover and flap assembly. A damaged vent assembly can allow entry of water, air, or rodents into vent ducts or home.  Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
Roof Drainage - Downspouts & Extensions 2
EXTENSIONS TOO SHORT
ONE OR MORE

One or more down spout extensions were too short. Recommend installing 6-8ft long (or greater as needed) extensions to divert rainwater runoff away from the property.

5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls
Ceilings & Walls 1
DAMAGED – WALLS
CLOSET

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

5.2.2 – Ceilings & Walls
Ceilings & Walls 2
MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

5.2.3 – Ceilings & Walls
Ceilings & Walls 3
Ceilings & Walls 4
MINOR CRACKS-WALLS
BEDROOMS

Minor cracking was visible on the interior walls.  A qualified contractor should evaluate and repair or replace as necessary.

5.2.4 – Ceilings & Walls
Ceilings & Walls 5
PAINT PEELING

The paint was peeling in areas.  A qualified contractor should evaluate and repair or replace as necessary.

5.3.1 – Floors
Floors 1
TRIP HAZARD

One section of flooring material was slightly higher than the neighboring material creating a trip hazard.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Windows
Windows 1
Windows 2
Windows 3
PEELING PAINT
ONE OR MORE THROUGHOUT PROPERTY

The window had peeling paint.  A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.2.1 – Doors
Doors 1
NOT INSTALLED PROPERLY

The door was not installed properly.  A qualified contractor should evaluate and repair or replace as necessary.

11 – Plumbing
11.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

13- Water Heating Equipment
13.6.1 – Combustion Air Supply
Combustion Air Supply 1
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

13.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

14 – Heating
14.1.1 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY
1996

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

14.12.1 – Heating System Ignition & Operation
FLAMES

The heating system did fire and appeared to be in serviceable condition at the time of the inspection. However, the appearance of the flames during operation indicated that gas combustion was not correct. Cleaning, servicing and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.

15 – Structural Crawlspace
15.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
Soil Vapor Barrier 2
BARRIER DAMAGED

The crawlspace vapor barrier was damaged in some areas, which compromises its effectiveness in reducing moisture and/or radon levels. A qualified contractor should evaluate and repair or replace as necessary.

15.6.1 – Insulation
Insulation 1
DAMAGED – INSULATION

The crawl space insulation was damaged. A qualified contractor should evaluate and repair or replace as necessary.