The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.
In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.
The paint was peeling in areas. A qualified contractor should evaluate and repair or replace as necessary.
The door had missing or damaged floor guides. A qualified contractor should evaluate and repair or replace as necessary.
An interior door rubs on the flooring when opening or closing. Recommend a qualified contractor evaluate and repair or replace as needed.
The spring rail assembly is damaged or not secured to the window sash. This may cause the sash to fail to stay open if not corrected. Recommend a qualified contractor evaluate and repair or replace as necessary.
The sealant was damaged, deteriorated or otherwise insufficient around the window. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.
An electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary.
One circuit was installed improperly with multiple GFCI outlets or breakers. This configuration prevents the GFCI outlets from resetting properly. A qualified contractor should evaluate and repair or replace as necessary.
The light fixture had a cracked or damaged cover. A qualified contractor should evaluate and repair or replace as necessary.
The light fixture was missing one or more bulbs. A qualified contractor should evaluate and repair or replace as necessary.
The ceiling fan wobbles when operated and may need to be balanced. A qualified contractor should evaluate and repair or replace as necessary.
An interior handrail was not continuous throughout an interior stairway.
Handrails for stairs must be continuous for the full length of the stairway.
At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.
The base cabinet was damaged. A qualified contractor should evaluate and repair or replace as necessary.
A GFCI outlet was defective and will not reset once tripped. A qualified contractor should evaluate and repair or replace as necessary.
The food waste disposer was missing the wiring connector (clamp and bushing). A qualified contractor should evaluate and repair or replace as necessary.
The vent hood light was not working at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
Although outside the scope of a general home inspection, the inspector noted the refrigerator ice and/or water dispenser was not working. A qualified contractor should evaluate and repair or replace as necessary.
The door was missing. A qualified contractor should evaluate and repair or replace as necessary.
The bathroom exhaust fan was very dirty and possibly clogged. A qualified contractor should evaluate and repair or replace as necessary.
The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.
In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.
With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.
The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.
In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.
With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.
The ceilings showed evidence that moisture was entering from behind possibly including damage and deterioration. A qualified contractor should evaluate and repair or replace as necessary.
The counter top needs caulking with silicone along the back splash. A qualified contractor should evaluate and repair or replace as necessary.
The drain stop did not work or did not hold water in the sink. A qualified contractor should evaluate and repair or replace as necessary.
The water supply valves and supply lines at the sink fixture in the bathroom were installed improperly with a reversed configuration. Current standards for installation produce hot water when the valve is turned to the left and cold water when the valve is turned to the right. A qualified contractor should evaluate and repair or replace as necessary.
The screen door was damaged or deteriorated at the time of inspection.
A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.
Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.
The HVAC system air filter was very dirty or clogged. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.
The blower motor, wheel, and/or cabinet appeared to be dirty at the time of inspection. Blower fans/wheels are subjected to constant dirt, dust, and lint and can become overly dirty when not cleaned on a regular basis and even faster if the air filters are not changed regularly.
A qualified contractor should evaluate, clean, and service as necessary, and certify the unit is in good working order.
The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.
Air flow to the air-conditioner condenser coils was restricted by vegetation, dirt, or debris. The unit should be cleaned and anything restricting air flow in or around the air conditioner should be removed in order to maintain cooling system efficiency and avoid problems from overheating of the compressor.
There is no insulation on the crawlspace exterior walls or floor system. Heat loss can occur more on this property than one that is properly insulated. A qualified contractor should evaluate and install as necessary.
The visible areas of the firebox and chimney flue were dirty at the time of the inspection. Most of the chimney flue was inaccessible and was not inspected. Dirty flues are potential fire hazards and should be cleaned by a professional. Recommend having the chimney evaluated by a C.S.I. (Chimney Safety Institute) -qualified chimney sweep.