4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
MISMATCH PAINT
LEFT FRONT CORNER

A spot in the exterior had mismatched paint touch up. A qualified contractor should evaluate and repair or replace as necessary.

4.10.1 – Window Wells
Window Wells 1
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Walkways
Walkways 1
Walkways 2
Walkways 3
SPALLING
FRONT

The walkway(s) had surface spalling in areas. This condition will continue to degrade if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
WATER PUDDLES
FRONT LEFT SIDE

Water puddles were on the ground surface that run along the fence line. Water puddling or ponding suggests the ground surface is not properly sloped away or graded away from the property. The sump pump also discharges at this area and could introduce more problems.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.19.1 – Decks & Balconies
Decks & Balconies 1
NOT CENTERED – SUPPORT POST

A support post was not properly centered and rested on a concrete footer. This may mean the deck is not properly supported. A qualified contractor should evaluate and repair or replace as necessary.

4.20.1 – Railings & Handrails
Railings & Handrails 1
Railings & Handrails 2
Railings & Handrails 3
BOWED/LOOSE – HANDRAIL

The guard/hand rail was loose and bowing. A fall or injury could occur if not corrected. This creates gaps along the handrail connections. A qualified contractor should evaluate and repair or replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions

Roof Drainage - Downspouts & Extensions 1

EXTENSIONS NOT POSITIONED PROPERLY
One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor evaluate and repair or replace as necessary.

5 – Attached Garage
5.3.1 – Ceiling, Walls & Firewalls
Ceiling, Walls & Firewalls 1
DAMAGED DOOR TRIM
The door trim in the garage is damaged and pulling away from the wall due to the loose/not secured steps. A qualified contractor should evaluate and repair or replace as necessary.
5.9.1 – Stairs & Railings
Stairs & Railings 1
LOOSE – STEPS/HANDRAIL

The steps and handrail are not properly secured. This condition may be a safety hazard if not corrected.

Correction and further evaluation is recommended.

9 – Bathroom
9.12.1 – Plumbing Fixtures
WHISTLING
PRIMARY BATHROOM

The supply line (behind the wall or at a fixture connection) whistled intermittently when more than one plumbing fixture was operated. Recommend a qualified contractor evaluate and repair or replace as needed.

Whistling or squealing water pipes generally results from water being forced through a smaller opening than the plumbing components were designed for. This is may be due to: water pressure too high, worn plumbing components, mineral build-up, or other issues that could only be discovered by dismantling the plumbing components.

10 – Bathroom 2
10.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – SPOUT/LEVER
UPSTAIRS GUEST BATHROOM

The tub spout had some damaged or cracking silicone caulking.  A qualified contractor should evaluate and repair or replace as necessary.

15 – Heating
15.9.1 – Air Filter
Air Filter 1
DIRTY

The HVAC system air filter was dirty. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

16 – Cooling

16.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

18 – Structural Basement
18.5.1 – Moisture Intrusion
Moisture Intrusion 1
Moisture Intrusion 2
Moisture Intrusion 3
MOISTURE INTRUSION

Water staining and deterioration was visible at the main water supply. It appears water has been coming in from behind the foundation wall and through the gap in the supply line. This is a serious issue and could create potential significant foundational issues and mold. A qualified contractor should evaluate and repair or replace as necessary.