2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.9.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MODERATE

The concrete driveway was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

4.2.2 – Driveways
Driveways 2
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
DAMAGED – SIDING

The siding and/or trim was damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
DETERIORATION

The exterior wall covering is beginning to deteriorate or has deteriorated.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 5
WOOD ROT

The siding and/or trim appeared to be rotted in areas. Recommend a qualified contractor evaluate and repair or replace as necessary.

4.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
Eaves, Soffits & Fascia 2
PEELING PAINT

The paint was peeling or cracking in one or more areas of the eaves.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.6.1 – Exterior Doors
Exterior Doors 1
BROKEN/CRACKED GLASS
FRONT

An entry door had a broken or cracked glass pane.  A qualified contractor should evaluate and repair or replace as necessary.

4.6.2 – Exterior Doors
Exterior Doors 2
Exterior Doors 3
Exterior Doors 4
DAMAGE – FRAME

The door frame appears to be damaged. This is possibly from excessive force such as ramming the door when locked, or from heavy usage. Recommend a qualified contractor evaluate and repair or replace as necessary.

4.8.1 – Electrical Outlets
Electrical Outlets 1
Electrical Outlets 2
GFCI – NOT ALL PROTECTED

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

4.8.2 – Electrical Outlets
Electrical Outlets 1
LOOSE OUTLET
BACK

An exterior electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.1 – Windows
Windows 1
Windows 2
Windows 3
FOGGED WINDOWPANE
BASEMENT

A window appeared fogged windowpane (a lost seal) from the exterior at the time of inspection.

If multiple-pane windows appear misty or foggy, it means that the seal protecting the window assembly has failed, and condensation has formed in between the two panes of glass.  Condensation in double-paned windows indicates that the glazing assembly has failed and needs repair or replacement.  Visible condensation can damage glazing and is the main indication of sealant failure.  Condensation is not always visible.  If the failure is recent, a failed window may not be obvious, since condensation doesn’t usually form until the window is heated by direct sunlight. Windows in the shade may show no evidence of failure, so it is nearly impossible to observe and report all failed double-paned windows.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.2 – Windows
MISSING – SCREEN

A window was a missing a window screen.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.3 – Windows
Windows 4
Windows 5
MISSING/DAMAGED – PAINT

A window frame, still, shutter, and/or trim was had missing or damaged paint. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.9.4 – Windows
Windows 6
WOOD ROT AT WINDOW

An exterior window has trim or framing appears to have wood rot. This may represent a general lack of maintenance or potential water intrusion issues.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways
Walkways 1
CRACK AT STEP(S)

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.2 – Walkways
Walkways 2
HEAVING AND/OR SETTLING

The walkway(s) showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
CORRODED – SPRINKLER SUPPLY VALVES

The lawn sprinkler system supply valves appeared to be corroded and/or leaking at time of inspection. A qualified contractor should evaluate and repair/replace as necessary according to current standards.

4.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
LEAKS AT ANTI-SIPHON

The exterior hose bib dripped from the anti-siphon when operated.

4.19.1 – Decks & Balconies
Decks & Balconies 1
Decks & Balconies 2
CRACKED, SPLIT WOOD – DECK

Cracked or split boards were present at the deck.  This condition is a structural defect and potential safety hazard.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.2 – Decks & Balconies
Decks & Balconies 3
DETERIORATED – FLOORING

There were deteriorated flooring components visible at the deck. Depending on the severity of the deterioration, use of the deck should be cautiously monitored.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.3 – Decks & Balconies
Decks & Balconies 4
MISSING – LEDGER FLASHING

Flashing was missing at the ledger board. This flashing problem may allow water to enter into the wall cavity or building components. A qualified contractor should evaluate and repair or replace as necessary.

4.19.4 – Decks & Balconies
Decks & Balconies 5
PEELING PAINT – DECK

The exterior deck floor and/or other components were peeling paint. A qualified contractor should evaluate and repair or replace as necessary.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

5.2.2 – Occupant Door
Occupant Door 2
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Floor
Floor 1
CRACKING – COMMON

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor evaluate and repair or replace as needed.

5.6.1 – Vehicle Door 2
Vehicle Door 2 1
 Vehicle Door 2 2NOT SEALED AT FLOOR

The garage door was missing weather stripping or did not evenly seal at the floor or sides of the door. A qualified contractor should evaluate and make adjustments, repair, or replace as necessary.

5.7.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

5.8.1 – Door Opener 2
Door Opener 2 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

 6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
PEELING WALLPAPER
BASEMENT BEDROOM
6.3.1 – Floors

Floors 1

Floors 2

CARPET LOOSE
BEDROOMS

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors
Doors 1
OFF TRACK
BASEMENT BEDROOM CLOSET

The sliding/folding door would fall off the track when operated.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Windows

Windows 1

Windows 2

Windows 3

BROKEN SEALS
THROUGHOUT PROPERTY

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass was observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

6.6.1 – Electrical Outlets
Electrical Outlets 1
OUTLET HOT AND NEUTRAL REVERSED
FRONT RIGHT BEDROOM

One or more electrical outlet(s) were wired incorrectly with the hot and neutral wires being reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created as there is still electricity running through the hot wire when the switch is off. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

6.7.1 – Electrical Fixtures & Switches

Electrical Fixtures & Switches 1

Electrical Fixtures & Switches 2

FAN MISSING REMOTE
THROUGHOUT PROPERTY FRONT LEFT BEDROOM

The ceiling fan did not respond to any wall switches. The fixture may be wired to be controlled by a remote but there was not remote available at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

6.12.1 – Bar Sink
Bar Sink 1
LEAKING – CONTROL VALVE
BAR SINK

The sink faucet leaked around the control valve.  A qualified contractor should evaluate and repair or replace as necessary.

6.13.1 – Bar Counter
Bar Counter 1
CAULKING/SEALANT NEEDS TOUCH UPS
BAR SINK

Caulking or sealant is deteriorated, missing, or in need of repair in one or more areas of the bar counter area. Recommend a qualified contractor evaluate and repair or replace as needed.

6.13.2 – Bar Counter
Bar Counter 2
CRACKING TILE
6.15.1 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
DEFECT AT DAMPER DOOR

The fireplace had a defect at the damper door. A qualified contractor should evaluate and repair or replace as necessary.

6.16.1 – Fireplace Wood-Burning 2
Fireplace Wood-Burning 2 1
CLEANING NEEDED

The visible areas of the firebox and chimney flue were dirty at the time of the inspection. Most of the chimney flue was inaccessible and was not inspected. Dirty flues are potential fire hazards and should be cleaned by a professional. Recommend having the chimney evaluated by a C.S.I. (Chimney Safety Institute) -qualified chimney sweep.

 8 – Laundry
8.4.1 – Exhaust Fan
FAN NEEDED

There was no ventilation (exhaust fan or openable window) In the laundry area. Normally an exhaust fan or an openable window is needed for proper ventilation.  A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Electrical Outlets
Electrical Outlets 1
FACEPLATE MISSING
LAUNDRY AREA

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

9.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN
PRIMARY BATHROOM

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.10.2 – Drain Waste and Vent System
Drain Waste and Vent System 2
CLOGGED/SLOW – TUB/SHOWER DRAIN
PRIMARY BATHROOM

The tub/shower drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
Plumbing Fixtures 2
CRACKED/DAMAGED – SINK

The sink was cracked or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.2 – Plumbing Fixtures
Plumbing Fixtures 3
LOOSE – SINK FAUCET
PRIMARY BATHROOM LEFT SINK

The sink faucet was loose.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.3 – Plumbing Fixtures
Plumbing Fixtures 4
CRACKED MIRROR
PRIMARY BATHROOM
9.14.1 – Tub, Shower Area
Tub, Shower Area 1
MISSING/DAMAGED GROUT
PRIMARY BATHROOM

Tiles on the wall in the bath/shower area had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.6.1 – Windows
Windows 1
SCREENS DAMAGED/MISSING
2ND FLOOR HALL BATHROOM

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – SHOWER PAN TOP

The tub/shower area had deteriorated or missing sealant (caulking or grout) where the shower wall rests on the tub and/or at the inside corners. A qualified contractor should evaluate and repair or replace as necessary.

 11 – Bathroom 3
11.3.1 – Exhaust Fan
Exhaust Fan 1
NOT WORKING
1ST FLOOR BATHROOM

The bathroom exhaust fan did not work.  A qualified contractor should evaluate and repair or replace as necessary.

11.7.1 – Electrical Outlets
Electrical Outlets 1
WILL NOT RESET
1ST FLOOR BATHROOM

A GFCI outlet was defective and will not reset once tripped. A qualified contractor should evaluate and repair or replace as necessary.

11.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
FLEX PIPE
1ST FLOOR BATHROOM

Flexible drain lines can clog, leak or fail. Flex lines design includes multiple folds in which moisture may become trapped and mold may grow.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 4
12.2.1 – Doors
Doors 1
STRIKE NOT LATCHING
BASEMENT BATHROOM

The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

12.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED
BASEMENT BATHROOM

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

12.6.1 – Windows
Windows 1
CRANK HANDLE MISSING
BASEMENT BATHROOM

The window had a missing crank handle.  A qualified contractor should evaluate and repair or replace as necessary.

12.9.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – COUNTER TOP

The counter top was damaged at the time of the inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

12.9.2 – Cabinets & Counters
Cabinets & Counters 2
GROUT – COUNTER TOP

The counter top tiles had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

12.14.1 – Tub, Shower Area
Tub, Shower Area 1
POSSIBLE MOLD

Evidence of a possible mold like substance was observed bath or shower area.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

12.14.2 – Tub, Shower Area
Tub, Shower Area 2
DETERIORATED – CAULKING/GROUT
BASEMENT BATHROOM

Caulking in the shower/tub area was deteriorated at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

 13 – Bathroom 5
13.5.1 – Floors
Floors 1
MISSING/DAMAGED GROUT
BASEMENT BATHROOM

The tile floor had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

 15 – Electrical
15.2.1 – Distribution Panels
Distribution Panels 1
MISSING – MANUFACTURERS LABEL

The manufacturer’s label was missing, partial, or illegible at the  electrical service panel. The manufacturer’s label typically provides information describing the main panel such as the name of the panel manufacturer, the panel model number, the panel amperage rating, limitations related to the environment in which the panel was designed to be installed and grounding/bonding information for that particular model. The Inspector was unable to confirm the existence of proper conditions when confirmation would require information taken from this missing label.

15.2.2 – Distribution Panels
WON’T STAY OPEN

Panel cover won’t stay open without a prop. This is a potential safety hazard for working on the panel.

15.8.1 – Sub-Panel
Sub-Panel 1
DOUBLE TAP

One or more circuit breakers have two wires that are connected to a breaker designed for only one wire. This is known as a “double-tap” and is a defective condition. A qualified contractor should evaluate and repair or replace as necessary.

 16 – Water Heating Equipment
16.3.1 – Pipe Connections
Pipe Connections 1
Pipe Connections 2
CORRODED – PIPE FITTINGS

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16.8.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
NO AIR GAP

The TPRV pipe did not discharge to an air gap within the same room as the water heater (Pipe vented through wall or floor.) A qualified contractor should evaluate and repair or replace as necessary.

16.12.1 – Operation & Response to Controls
Operation & Response to Controls 1
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

16.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

 17 – Heating Upstair
17.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

17.1.2 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

17.6.1 – Cabinet
Cabinet 1
Cabinet 2
INADEQUATE WORKSPACE

A proper workspace platform of 30 inches by 36 inches is required in front of the cabinet. A stable pathway no less than 22 inches by 30 inches is required leading from access to the platform. An outlet and a light are required to be installed for maintenance and service personnel to work. Recommend a qualified contractor evaluate and repair or replace as necessary.

17.10.1 – Blower
FAN BLOWER NOISE

The blower fan for HVAC system was excessively noisy during operation. A qualified contractor should evaluate and repair or replace as necessary.

 18 – Heating downstairs
18.6.1 – Cabinet
Cabinet 3
CORRODED, RUSTED

The heating system cabinet was corroded, rusted or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

18.10.1 – Blower
Blower 1
BLOWER WHEEL DIRTY

The blower motor and/or wheel appeared to be dirty at the time of inspection. Blower fan motors and fan wheels are subjected to constant dirt, dust, and lint and can become overly dirty when not cleaned on a regular basis and even faster if the air filters are not changed regularly.

A qualified contractor should evaluate, clean, and service as necessary, and certify the unit is in good working order.

 19 – Cooling upstairs
19.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

19.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 20 – Cooling downstairs
20.1.1 – Cooling System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

20.1.2 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

20.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
GAP AROUND LINE AT WALL

The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.

20.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.