4 – Attached Garage
4.4.1 – Floor
Floor 1
STAINED

The garage floor was heavily stained. A qualified contractor should evaluate and repair or replace as necessary.

4.5.1 – Vehicle Door
Vehicle Door 1
DAMAGE – PANELS

The garage door panelling was dented, corroded, or damaged and should be further evaluated by a qualified contractor to repair or replace as needed.

 5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls
Ceilings & Walls 1
Ceilings & Walls 2
EVIDENCE OF RODENTS

Although outside the scope of normal home inspection the inspector noticed possible evidence of rodents. A qualified contractor should evaluate and repair or replace as necessary.

5.3.1 – Floors
Floors 1
FLOOR SQUEAKS
PRIMARY BEDROOM

The floor squeaks when stepped on.  Because of the age of the home and the severity of the squeak it is recommended that the carpet pulled up to determine the cause. A qualified contractor should evaluate and repair or replace as necessary.

5.3.2 – Floors
Floors 2
HOLES

There were holes drilled in the floor of the base of the stairs. A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Doors
Doors 1
MISSING – STRIKE PLATE
BACK BEDROOM

The door was missing a strike plate at the door jamb.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.2 – Doors
Doors 2
SLIDE LATCH DIFFICULT
PRIMARY BEDROOM

The door had a slide latch that was difficult to operate.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Windows
Windows 1
DIFFICULT TO OPEN/CLOSE

A window had a sash that was difficult to slide or operate to get opened/closed.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Windows
Windows 2
SCREEN NOT WORKING

The large electric screen installed outside the garage door in the living room was not functioning at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.3 – Windows
Windows 3
Windows 4
DAMAGED – BLINDS
BACK CORNER BEDROOM, LIVING ROOM

Window blinds were damaged at the time of inspection. This may be that the plastic was broken or missing or the blinds did not operate properly. Recommend a qualified contractor evaluate and repair or replace as needed.

5.5.4 – Windows
Windows 5
CURTAINS FADED

The curtains in the living room were faded from the sun. A qualified contractor should evaluate and repair or replace as necessary.

5.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
FAN NOT WORKING
PRIMARY

The ceiling fan did not work. A qualified contractor should evaluate and repair or replace as necessary.

 6 – Kitchen
6.2.1 – Doors
Doors 1
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.2 – Cabinets & Counters
Cabinets & Counters 2
WORN FINISH

Counters or cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

 8 – Bathroom
8.2.1 – Doors
Doors 1
MISSING – STRIKE PLATE

The door was missing a strike plate at the door jamb.  A qualified contractor should evaluate and repair or replace as necessary.

8.4.1 – Ceilings & Walls
Ceilings & Walls 1
GRAB BAR LOOSE

The grab bar in the primary bathroom was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

8.14.1 – Tub, Shower Area
Tub, Shower Area 1
STAINS

The shower pan in the primary bathroom was stained. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom 2
9.2.1 – Doors
Doors 1
STRIKE NOT LATCHING

The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Plumbing
12.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

12.7.1 – Sump Pit
Sump Pit 1
Sump Pit 2
NO PUMP/WATER LEVEL HIGH

The property contained a pit for a sump pump, but no pump was installed. The water level in the sump pit at the time of the inspection was higher than what is considered acceptable. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

A sump pump system protects the property from water intrusion by discharging rising groundwater or by routing surface drainage via the property perimeter drain to the pit, from where it is discharged by the pump to the exterior of the property or to a waste pipe or storm drain. Sump pumps require periodic maintenance to ensure that they work when they’re needed and should be tested on an annual basis to ensure they are in working order. The pumps can be tested by lifting the float, but to avoid potential shock/electrocution hazard testing should be performed using a tool which will not conduct electricity. Pumps have a filter that should be cleaned during routine maintenance.

 13 – Electrical
13.2.1 – Distribution Panels
Distribution Panels 1
SCREWS MISSING – PANEL COVER

Screws / fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

 15 – Heating
15.9.1 – Air Filter
Air Filter 1
VERY DIRTY

The HVAC system air filter was very dirty or clogged. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

15.9.2 – Air Filter
Air Filter 2
Air Filter 3
SECOND FILTER

There was a second very dirty filter laying in the cabinet below the installed filter. A qualified contractor should evaluate and repair or replace as necessary.

 16 – Cooling
16.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 17 – Fireplace or Stove
17.1.1 – Electric Fireplace
Electric Fireplace 1
FRAME BENT
The metal frame around the fireplace was bent. A qualified contractor should evaluate and repair or replace as necessary.