The roof covering material was damaged/deteriorated in some areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.
A light in the attic was missing the bulb at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The outlet that powers the radon fan had no power at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The soffit was damaged in one or more areas.
Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The master GFCI reset outlet connected to the exterior outlets would trip when the crawl space light switch was turned on. A qualified contractor should evaluate and repair or replace as necessary.
Some of the trim around the exterior windows was improperly finished. A qualified contractor should evaluate and repair or replace as necessary.
Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The garage window had a loose spring rail at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The ceilings showed signs of minor damage and wear. A qualified contractor should evaluate and repair or replace as necessary.
The walls showed signs of minor damage and wear. A qualified contractor should evaluate and repair or replace as necessary.
The floors throughout the home were not protected during construction. Both hard flooring and carpet were very dirty and it was difficult to tell if there was damage or stains. Generally they are better protected during a new build. A qualified contractor should evaluate and repair or replace as necessary.
The door had missing or damaged floor guides. A qualified contractor should evaluate and repair or replace as necessary.
The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.
Some windows had damaged or missing screens. A qualified contractor should evaluate and repair or replace as necessary.
One light switch plate in the kitchen area was crooked. A qualified contractor should evaluate and repair or replace as necessary.
The drywall was cut out for an access hole. A qualified contractor should evaluate and repair or replace as necessary.
The kitchen drawers were difficult to operate. A qualified contractor should evaluate and repair or replace as necessary.
The toe kick trim at the base of the cabinets was missing at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
An electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary.
The laundry room did not have an exhaust fan or an openable window. Even though it may not be required in the county, the generally accepted standard is that there be ventilation installed. A qualified contractor should evaluate, then repair or replace as advised.
The floor covering was not sealed at the edges and may allow moisture intrusion. A qualified contractor should evaluate and repair or replace as necessary.
The toe kick trim at the base of the cabinets was missing at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The distribution piping runs from the main source to each faucet or fixture.
A water distribution pipe was leaking at the time of inspection.
A qualified contractor should evaluate and repair or replace as necessary.
The property water supply pressure measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.
A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.
Multiple circuit breakers were missing in the electric panel at the time of inspection. A qualified contractor should evaluate and repair and replace as necessary.
There was a secondary electrical switch in the furnace room. It was unclear with the switch was for. If it was for a light there was no light installed. A qualified contractor should evaluate and repair or replace as necessary.
The interior of the furnace cabinet was very dirty and should be cleaned. A qualified contractor should evaluate and repair or replace as necessary.
The furnace did not fire at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The active ventilation fan was not working at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.
Because the GFCI outlet near the switch trips the crawlspace light would not work A qualified contractor should evaluate and repair or replace as necessary.