2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
Roof Covering 3
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.2.2 – Roof Covering
Roof Covering 4
DEGRANULATED

Some of the shingles appeared to be de-granulated in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
TOO SHORT

A plumbing vent did not extend far enough above the roof. A plumbing vent should extend a minimum of 10″.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation, and Ventilation
3.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor to evaluate and repair or replace as needed.

 4 – Exterior
4.7.1 – Electrical Fixtures
Electrical Fixtures 1
NOT WORKING – BULB
FRONT

A bulb at an exterior light fixture did not respond to the switch at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

4.8.1 – Electrical Outlets
Electrical Outlets 1
MISSING WEATHERPROOF COVERING
BACK

The exterior electrical outlet was missing an in-use weatherproof covering. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways
Walkways 1
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
CORRODED – SPRINKLER SUPPLY VALVES

The lawn sprinkler system supply valves appeared to be corroded and/or leaking at the time of inspection. A qualified contractor should evaluate and repair/replace as necessary according to current standards.

4.18.1 – Exterior Vents
Exterior Vents 1
CLOGGED DRYER VENT

A vent connected to the clothes dryer was clogged and is a potential fire hazard.  A qualified contractor should evaluate to clean, repair, or replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
EXTENSIONS NOT POSITIONED PROPERLY

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

 5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazards and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

5.6.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

 6 – Interior, Doors, Windows
6.5.1 – Windows
Windows 1
Windows 2
BROKEN SEALS
PRIMARY BEDROOM

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass were observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

6.5.2 – Windows

Windows 3

Windows 4

DIFFICULT TO OPEN/CLOSE

A window had a sash that was difficult to slide or operate to get opened/closed.  A qualified contractor should evaluate and repair or replace as necessary.

 7 – Kitchen
7.12.1 – Food Waste Disposer
Food Waste Disposer 1
MISSING WIRING CLAMP

The food waste disposer was missing the wiring connector (clamp and bushing).  A qualified contractor should evaluate and repair or replace as necessary.

7.14.1 – Range/Oven/Cooktop
Range/Oven/Cooktop 1
NOT IGNITING – BURNER

A cooktop burner was not igniting at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.11.1 – Dryer Vent Piping
Dryer Vent Piping 1
KINKED/DAMAGED

A dyer vent connection was installed in the laundry area. The dryer vent was kinked and/or damaged at the back of the dryer.  The inspector recommends repairing or replacing the dryer vent to prevent restricting dryer exhaust air flow, the restriction of which can result in lint accumulation or vent blockage which can cause the dryer to overheat; a potential fire hazard and a condition that will shorten the dryers life span. A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH

The countertop needs caulking with silicone along the backsplash.  A qualified contractor should evaluate and repair or replace as necessary.

9.14.1 – Tub, Shower Area
Tub, Shower Area 1
POSSIBLE MOLD
PRIMARY BATHROOM

Evidence of a possible mold-like substance was observed bath or shower area.  We did not inspect, test, or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

 11 – Bathroom 3
11.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH

The countertop needs caulking with silicone along the backsplash.  A qualified contractor should evaluate and repair or replace as necessary.

11.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
LEAK – SHOWER HEAD

There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as necessary.

 12 – Bathroom 4
12.3.1 – Exhaust Fan
NOT PRESENT – FAN RECOMMENDED

There was not an exhaust fan in the bathroom. An exhaust fan or an openable window is needed for proper ventilation.

Some bathroom designs may require installing an exhaust fan in addition to an openable window to achieve proper ventilation.

Should proper ventilation rely solely on an openable window, the window may need to be opened during adverse weather conditions for the ventilation to happen. Using an exhaust fan is the recommended alternative.

A qualified contractor should evaluate and repair or replace as necessary.

 13 – Plumbing
13.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure is measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances are likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 15 – Water Heating Equipment
15.4.1 – Expansion Tank / Valve
Expansion Tank / Valve 1
NOT SECURED

The expansion tank was not properly secured. A qualified contractor should evaluate and repair or replace as necessary.

15.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

 17 – Cooling
17.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

17.3.1 – AC Compressor
AC Compressor 1
AC Compressor 2
COIL FINS DAMAGED
There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

19 – Structural Basement

19.8.1 – Vapor Barriers

Vapor Barriers 1
VAPOR BARRIER DAMAGED

The vapor barrier was damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.