2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

 3 – Attic, Insulation, and Ventilation
3.3.1 – Attic Moisture Intrusion
Attic Moisture Intrusion 1
WATER INTRUSION

Signs of previous water penetration or intrusion into the attic. Watermarks or stains were observed. Recommend asking the seller if there are any recent incidents that have been documented or mitigated.

Further evaluation is recommended.

3.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor to evaluate and repair or replace as needed.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
SPALLING

The driveway surface was spalling in areas. This condition will continue to degrade if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
ARTILLERY FUNGUS

The home had evidence of artillery (or shotgun) fungus. Artillery fungus is a wood decay fungus that likes to live on moist landscape mulch. It can shoot spores up to 20 feet which often land on siding or anything that surrounds the mulch. The fungus does not damage siding or have any negative health effects but is difficult to remove.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
Wall-Covering, Flashing & Trim 4
DAMAGED – SIDING

The siding and/or trim were damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 5
PENETRATIONS

There were penetrations in areas of the siding at the time of inspection. Recommend applying the appropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.

4.6.1 – Exterior Doors
Exterior Doors 1
Exterior Doors 2
DAMAGE – FRAME

The door frame appears to be damaged. This is possibly from excessive force such as ramming the door when locked, or from heavy usage. Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.9.1 – Windows
Windows 1
DAMAGED – FRAME

The window frame was damaged. A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Walkways
Walkways 1
Walkways 2
CRACK AT STEP(S)

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
ERODED GRADE

Grade has eroded or was poorly back-filled near the foundation wall, patio, or stairway. This may allow moisture to pool near the structure, and this may allow significant cracking if not corrected.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

4.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
MINOR CORROSION

Pipes or valves had minor surface corrosion at the sprinkler supply line. Monitoring and contacting a qualified professional to further evaluate for repairs is recommended

4.13.2 – Sprinkler System Supply Line
Sprinkler System Supply Line 2
CAP AT ANTI-SIPHON DAMAGED

The cap of the anti-siphon valve is damaged. This may allow unwanted debris and enter the system. Recommend qualified contractors to evaluate and repair or replace as needed.

4.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
DRIPS AT KNOB

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.17.1 – Exterior Foundation Wall
xterior Foundation Wall 1
CRACKS – AT CORNER(S)

The exterior foundation wall had cracks at the corner. A qualified contractor should evaluate and repair or replace as necessary.  Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

4.19.1 – Decks & Balconies
Decks & Balconies 1
CONTACT WITH GROUND

A wood support post or wood portion of the deck was in direct contact with the ground/dirt. The wood should be pressure treated and ideally be: placed in a metal bracket and/or cement casing, and have clearance from the ground level. Wood in direct contact with dirt will wick up ground moisture and deteriorate at an accelerated rate if routine maintenance is not kept.

Recommend a qualified contractor to evaluate and repair or replace as needed.

4.20.1 – Railings & Handrails
Railings & Handrails 1
MISSING – HANDRAIL
A stairway of more than 3 steps or drop of over 30″ was missing a handrail.

4.20.2 – Railings & Handrails

Railings & Handrails 2
DETERIORATED

A handrail was deteriorated or damaged at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
Roof Drainage - Downspouts & Extensions 2
Roof Drainage - Downspouts & Extensions 3
MISSING – EXTENSIONS

The downspout (s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 5 – Attached Garage
5.6.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

 6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
Ceilings & Walls 2
CRACKING AROUND WINDOW

There was cracking around some windows on the interior (where the window meets the wall).  A qualified contractor should evaluate and repair or replace as necessary.

6.2.2 – Ceilings & Walls
Ceilings & Walls 3
Ceilings & Walls 4
MOISTURE DAMAGE-CEILINGS

The ceilings showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.3 – Ceilings & Walls
MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.4 – Ceilings & Walls
Ceilings & Walls 5
PAINT PEELING

The paint was peeling in areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.6.1 – Electrical Outlets
Electrical Outlets 1
DAMAGED – OUTLET

An electrical outlet was broken/damaged. A qualified contractor should evaluate and repair or replace as necessary.

6.6.2 – Electrical Outlets

Electrical Outlets 2

LOOSE – OUTLET

An electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

 7 – Kitchen
7.15.1 – Range Hood
Range Hood 1
THE LIGHT DID NOT WORK

The vent hood light was not working at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Laundry
8.9.1 – Electrical Outlets
Electrical Outlets 1
GFCI PROTECTION IS NOT PRESENT

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

8.11.1 – Dryer Vent Piping
Dryer Vent Piping 1
NO VENT CONNECTION

No vent connection was provided for the dryer. Lack of proper dryer venting to the exterior may result in excessively high humidity levels which can damage property materials or components and may encourage the growth of microbes such as mold. Lack of proper dryer venting can also result in the accumulation of lint on the property. Lint is combustible and its accumulation is a potential fire hazard and a possible health hazard from the inhalation of particulates. The Inspector recommends proper installation of an Underwriter’s Laboratory (UL) approved dryer vent for safety reasons. Dryer vents should be clean annually to ensure that safe conditions continue to exist.

 9 – Bathroom
9.2.1 – Doors
Doors 1
MISSING – STRIKE PLATE

The door was missing a strike plate at the door jamb.  A qualified contractor should evaluate and repair or replace as necessary.

9.11.1 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 1
CORRODED

The water supply valve was corroded at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

9.11.2 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 2
KNOB – DAMAGED/MISSING

The water supply shutoff valve had a damaged or missing knob.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.13.1 – Toilets
Toilets 1
FLUSH-HOLD LEVER DOWN

The toilet won’t flush unless the lever is held down briefly.  A qualified contractor should evaluate and repair or replace as necessary.

 11 – Bathroom 3
11.3.1 – Exhaust Fan
Exhaust Fan 1
DAMAGED/MISSING COVER

The bathroom exhaust fan had a damaged or missing cover.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Plumbing
12.4.1 – Water Pressure
Water Pressure 2
HIGH WATER PRESSURE

The property water supply pressure is measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances are likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 13 – Electrical
13.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power to.

Recommend a qualified contractor to verify the breakers and accuracy of any existing labeling as necessary.

 14 – Water Heating Equipment
14.11.1 – Burn Chamber
Burn Chamber 1
RUST CORROSION

The water heater burn chamber had rust/corrosion visible. A qualified contractor should evaluate and repair or replace as necessary.

14.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

 15 – Heating
15.1.1 – Heating System Information
Heating System Information 1
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

15.10.1 – Blower
Blower 1
BLOWER WHEEL DIRTY

The blower motor and/or wheel appeared to be dirty at the time of inspection. Blower fan motors and fan wheels are subjected to constant dirt, dust, and lint and can become overly dirty when not cleaned on a regular basis and even faster if the air filters are not changed regularly.

A qualified contractor should evaluate, clean, and service as necessary, and certify the unit is in good working order.

15.11.1 – Thermostat & Normal Operating Controls
Thermostat & Normal Operating Controls 1
THERMOSTAT LOOSE

The thermostat was loose and needs to be properly secured. A qualified contractor should evaluate and repair or replace as necessary.

 16 – Cooling
16.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

16.2.2 – AC Refrigerant Lines
REFRIGERANT LINES TOO LONG

The refrigerant lines may have been too long. HVAC systems are normally charged with refrigerant capable of handling 50 feet of refrigeration line. It is critical that the refrigeration capacity be kept to a minimum. A simple adjustment of charge may be necessary when longer. Recommend a qualified contractor to evaluate and repair or replace as needed.

16.4.1 – AC Service Disconnect
AC Service Disconnect 1
INCORRECT BREAKER RATING

The circuit breaker was rated higher than the capacity listed on the compressor’s manufacture label. This condition could damage the unit or possibly start an electrical fire. Recommend having a qualified contractor repair or replace as necessary.

16.6.1 – Cooling System Operation
DID NOT PRODUCE COOLED AIR

The cooling system turned on but did not operate as expected by producing adequately conditioned cooled air. An ambient air test was performed to determine if the difference in temperatures of the supply and return air was between 14 degrees and 22 degrees. A qualified contractor should evaluate and repair/replace as necessary.

 17 – Structural Crawlspace
17.3.1 – Moisture Intrusion
Moisture Intrusion 1
Moisture Intrusion 2
ACTIVE LEAK
The inspector observed signs of a possible active leak in the crawlspace.