2 – Roof
2.2.1 – Roof Covering
CRACKED TILE

One or more tiles show signs of cracks.   A qualified contractor should evaluate and repair or replace as necessary.

2.2.2 – Roof Covering
Roof Covering 1
Roof Covering 2
Roof Covering 3
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate and repair or replace as necessary.

2.2.3 – Roof Covering
Roof Covering 4
Roof Covering 5
DEGRANULATED

Some of the shingles appear to be de-granulated in areas. Recommend a qualified contractor to evaluate and repair or replace as necessary.

2.2.4 – Roof Covering
Roof Covering 6
Roof Covering 7
EXPOSED NAILS

The roof covering the head exposed nails in one or more areas. Recommend a qualified contractor to evaluate to seal the nail head openings or make general repairs or replacements as necessary.

2.2.5 – Roof Covering
Roof Covering 8
Roof Covering 9
HAIL/WIND/FOOT DAMAGE

The roof covering had minor damage from hail, wind, and/or foot traffic.  A qualified contractor should evaluate and repair or replace as necessary.

2.2.6 – Roof Covering
Roof Covering 10
NEARING END OF LIFE CYCLE

The roof covering is nearing the end of its life cycle.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

2.4.1 – Flashing
Flashing 1
Flashing 2
RIDGE FLASHING DAMAGED

The ridge shingles used to protect areas of the roof from moisture intrusion are damaged in areas. A qualified roofing contractor should inspect and repair as necessary.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
TOO SHORT

The plumbing vent did not extend far enough above the roof. A plumbing vent should extend a minimum of 6″ above the snow line, which is considered approximately 10″.  A qualified contractor should evaluate and repair or replace as necessary.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
NOT PRESENT
 3 – Exterior
3.2.1 – Driveways
Driveways 1
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
ARTILLERY FUNGUS

The home had evidence of artillery (or shotgun) fungus. Artillery fungus is a wood decay fungus that likes to live on moist landscape mulch. It can shoot spores up to 20 feet which often land on siding or anything that surrounds the mulch. The fungus does not damage siding or have any negative health effects but is difficult to remove.

Recommend a qualified contractor should evaluate and repair or replace as needed.

3.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
Wall-Covering, Flashing & Trim 4
Wall-Covering, Flashing & Trim 5
DAMAGED – SIDING

The siding and/or trim were damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

3.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
TREE BRANCHES OVER PROPERTY

Large trees near the house have branches that overhang the property. Falling branches due to conditions such as wood decay, high winds, or heavy snow loads may cause injury, death, or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

3.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
SIGNIFICANT LEAK – KNOB

The outside water faucet had a significant leak from the knob/handle when the water pressure gauge was attached. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3.19.1 – Decks & Balconies
Decks & Balconies 1
PEELING PAINT – DECK

The exterior deck floor and/or other components were peeling paint. A qualified contractor should evaluate and repair or replace as necessary.

 4 – Interior, Doors, Windows
4.2.1 – Ceilings & Walls
Ceilings & Walls 1
ASBESTOS CEILING

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn textures were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, are generally considered non-friable and not hazardous. Heat, water, weathering, or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized, or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized, or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

4.2.2 – Ceilings & Walls
Ceilings & Walls 2
DAMAGED – TRIM

Accent trim was damaged in areas of the interior walls at the time of inspection.

Recommend a qualified contractor to evaluate and repair or replace as needed.

4.2.3 – Ceilings & Walls
Ceilings & Walls 3
Ceilings & Walls 4
DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

4.2.4 – Ceilings & Walls
Ceilings & Walls 5
MOISTURE STAINING-CEILINGS

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

4.2.5 – Ceilings & Walls
Ceilings & Walls 6
MOISTURE STAINING-WALLS

The wall showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

4.2.6 – Ceilings & Walls
Ceilings & Walls 7
SIGNS OF REPAIR-WALLS

The interior walls have signs of repairs. Recommend asking the current homeowner for more information. Recommend further evaluation from a qualified contractor should the repairs be excessive or of visibly poor quality.

4.3.1 – Floors
Floors 1
CARPET STAINS

The carpet was stained in areas. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Doors
Doors 1
DAMAGED – DOOR

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

4.5.1 – Windows
Windows 1
WORN OR NEARING THE END OF LIFE EXPECTANCY

Windows installed in the home appeared to be worn or aged. This apparent condition can mean the windows are deteriorated or difficult to operate, and can also mean they are not consistent with current efficiency standards. They were possibly original and were either at or near their serviceable lifespan. Recommend further evaluation by a qualified contractor and budgeting for potential future replacement.

4.6.1 – Electrical Outlets
Electrical Outlets 1
NOT GROUNDED – OUTLET

One or more electrical outlets were not grounded. A qualified contractor should evaluate and repair or replace as necessary.

4.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB(S)

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as needed.

4.7.2 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 2
FAN NOT WORKING

The ceiling fan did not work. A qualified contractor should evaluate and repair or replace as necessary.

 5 – Kitchen
5.5.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinets over the years.

A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Cabinets & Counters
Cabinets & Counters 2
LOOSE – COUNTERTOP

The countertop was loose and not fastened securely.  A qualified contractor should evaluate and repair or replace as necessary.

5.6.1 – Electrical Outlets
Electrical Outlets 1
OUTLET NOT WORKING

An electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary.

5.11.1 – Water Supply Shutoff Valves
Water Supply Shutoff Valves 2
CORRODED

The water supply valve was corroded at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

5.13.1 – Dishwasher
Dishwasher 1
NOT OPERATIONAL

The dishwasher was not operational at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

5.14.1 – Range/Oven/Cooktop
Range/Oven/Cooktop 1
DAMAGED – CONTROL KNOB

The stove/oven knob was damaged and did not operate properly.  A qualified contractor should evaluate and repair or replace as necessary.

5.17.1 – Refrigerator
Refrigerator 1
LOOSE HANDLE

The refrigerator had a loose handle. A qualified contractor should evaluate and then repair or replace as advised.

 7 – Bathroom
7.2.1 – Doors
Doors 1
NOT LOCKING

The door did not lock properly.  A qualified contractor should evaluate and repair or replace as necessary.

7.3.1 – Exhaust Fan
Exhaust Fan 1
NOT WORKING

The bathroom exhaust fan did not work.  A qualified contractor should evaluate and repair or replace as necessary.

7.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE STAINING-CEILINGS

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

7.4.2 – Ceilings & Walls
Ceilings & Walls 2
MOISTURE STAINING-WALLS

The wall showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

7.7.1 – Electrical Outlets
Electrical Outlets 1
NOT GROUNDED – GFCI OUTLET

A GFCI outlet was not grounded and did not trip when tested. A GFCI requires a ground wire to route electricity when tripped. A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED SINK
7.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

7.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
LOOSE-TUB FAUCET

The tub faucet/spout was loose.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
DIVERTER VALVE STUCK
7.13.1 – Toilets
Toilets 1
LID CRACKED/MISSING

The toilet had a cracked or missing tank lid.  A qualified contractor should evaluate and repair or replace as necessary.

7.13.2 – Toilets
Toilets 2
LOOSE ON THE FLOOR

The toilet was loose on the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. The loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

7.14.1 – Tub, Shower Area
Tub, Shower Area 1
POSSIBLE MOLD

Evidence of a possible mold-like substance was observed bath or shower area.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

7.14.2 – Tub, Shower Area
Tub, Shower Area 2
STAINED, DIRTY

The shower pan or tub is dirty and possibly stained at the time of the inspection. Recommend further evaluation from a qualified professional for cleaning, repairs, or replacement.

7.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
NO COLD WATER
 8 – Bathroom 2
8.3.1 – Exhaust Fan
Exhaust Fan 1
NOISY, DAMAGED

The bathroom exhaust fan was noisy when on. The noise was likely a sign of damage.  A qualified contractor should evaluate and repair or replace as necessary.

8.4.1 – Ceilings & Walls
Ceilings & Walls 1
DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

8.4.2 – Ceilings & Walls
 Ceilings & Walls 2
MOISTURE DAMAGE-CEILINGS

The ceilings showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

8.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CRACKED/DAMAGED – TUB

The bathtub was cracked or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

8.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
DAMAGED CONTROL KNOBS
8.13.1 – Toilets
Toilets 1
Toilets 1
CRACK – BOWL

The toilet had a crack in the bowl.  A qualified contractor should evaluate and repair or replace as necessary.

8.14.1 – Tub, Shower Area
Tub, Shower Area 1
CRACKED/DAMAGED – TUB

The bathtub was cracked or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

 9 – Plumbing
9.3.1 – Water Supply & Distribution Systems
Water Supply & Distribution Systems 1
POLYBUTYLENE

Property distribution pipes were polybutylene.

Polybutylene piping similar in appearance to the piping in this home has been the subject of a national class action lawsuit involving certain polybutylene plumbing systems and polybutylene yard service lines installed between July 1, 1978-July 31, 1995. While scientific evidence is scarce, it is believed that oxidants in the public water supplies, such as chlorine, react with the polybutylene and acetyl fittings causing them to scale, flake, and become brittle.  Micro-fractures result and the structural integrity of the water distribution system is compromised. The system may become weak and fail without warning causing damage to the building structure and personal property.

Throughout the 1980s lawsuits were filed complaining that allegedly defective manufacturing and installation caused hundreds of millions of dollars in damages.  Although the manufacturers have never admitted that this material is defective, they agreed to fund the Class Action settlement with an initial and minimum amount of $950. As of May 2009 the class is now closed and no further funds are available.   A qualified contractor should evaluate and repair or replace as necessary.

 10 – Electrical
10.2.1 – Distribution Panels
Distribution Panels 1
DAMAGE – PANEL

The electrical panel was damaged. A qualified contractor should evaluate and repair or replace as necessary.

 11 – Water Heating Equipment
11.2.1 – Water Shut-Off
Water Shut-Off 1
NOT PRESENT

There was no shut-off valve installed on the water heater supply line. This means to replace the water heater the water would need to be turned off to the whole house. A qualified contractor should evaluate and repair or replace as necessary.

11.8.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
MISSING – PIPE

The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Heating
12.1.1 – Heating System Information
Heating System Information 1
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

 13 – Cooling
13.1.1 – Cooling System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

13.1.2 – Cooling System Information
COOLING SYSTEM INACCESSIBLE

The cooling system condenser cabinet was inaccessible. A qualified contractor should evaluate and repair/replace as necessary prior to your inspection objection deadline.

13.1.3 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

13.1.4 – Cooling System Information
SWAMP COOLER IS NOT OPERATIONAL
13.6.1 – Cooling System Operation
OLD SYSTEM

The HVAC system appeared to be near the end of its service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate and repair or replace as necessary.  InterNACHI’s Standard Estimate Life Expectancy Chart for HomesChart for Homes