2 – Roof
2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
STANDING WATER

The gutter at the front of the home had standing water at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

 3 – Attic, Insulation, and Ventilation
3.1.1 – Attic Access
Attic Access 1
Attic Access 2
HATCH INSULATION LOSE

The attic access hatch had insulation that was not secured to the access hatch. A qualified contractor should evaluate and repair or replace as necessary.

3.4.1 – Insulation in Attic
Insulation in Attic 1
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor to evaluate and repair or replace as needed.

3.5.1 – Ventilation in Attic
Ventilation in Attic 1
VENTILATION INADEQUATE

Ventilation may have been insufficient at the time of the inspection.

Inadequate attic ventilation can cause the attic to overheat, causing heat damage to the roof covering, which results in a decreased life expectancy. Adequate ventilation of the attic will actually help prolong the life expectancy of the roof covering and help stabilize interior temperatures when heating and cooling is in use.

Recommend a qualified contractor evaluate to ensure all attic ventilation is unobstructed and fully functional and/or install additional ventilation as needed.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
DROPPED SURFACE/SLAB

The driveway has dropped or settled in areas, causing a steep or uneven step. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
BULGE

The wall was bowed or bulged in areas.  A qualified contractor should evaluate and repair or replace as necessary.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
Wall-Covering, Flashing & Trim 3
DETERIORATION

The exterior wall covering is beginning to deteriorate or has deteriorated.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 4
Wall-Covering, Flashing & Trim 5
INADEQUATE GROUND CLEARANCE

The distance between the bottom of wood components and the ground surface (or grade) was not sufficient. There should be a 6-inch gap between the bottom of the siding and the ground and a 2-inch gap between the bottom of the siding and hard surfaces.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 6
Wall-Covering, Flashing & Trim 7
Wall-Covering, Flashing & Trim 8
LIFTED NAILS
MANY

The siding/trim has lifted nails and needs to be tightened.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.5 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 9
Wall-Covering, Flashing & Trim 10
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.6 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 11
Wall-Covering, Flashing & Trim 12
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.7 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 13
Wall-Covering, Flashing & Trim 14
SWOLLEN – MOISTURE INTRUSION

The siding/trim had a swollen appearance due to moisture intrusion.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.8 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 15
BOLTS

There were bolts in the siding and trim on the right side of the home that should be removed and sealed. A qualified contractor should evaluate and repair or replace as necessary.

4.6.1 – Exterior Doors
DOORBELL NOT WORKING

The doorbell was not working at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

4.6.2 – Exterior Doors
Exterior Doors 1
DAMAGE – DOOR
FRONT

The surface of the exterior door was damaged or in poor condition.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.1 – Walkways
Walkways 1
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving, or settling, depending on soil composition, moisture content, and other conditions. The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters, and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
DRIPS AT KNOB
BACK

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.18.1 – Exterior Vents
Exterior Vents 1
THE VENT FLAP STUCK OPEN

The dryer vent had a flap that was stuck open. The clothes dryer vent may be clogged which is a potential fire hazard. This may also allow rodents or insects to enter the interior.  Recommend qualified contractors should evaluate and clean, repair, or replace as necessary.

 6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors
STRIKE NOT LATCHING
HALL CLOSET

The door would not latch when closed and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

6.5.1 – Windows
Windows 1
BROKEN SEALS
PRIMARY BEDROOM

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass were observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
CO DETECTOR >15 FEET

Carbon monoxide detectors were installed in greater than 15 feet of rooms used for sleeping purposes. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage within a specified distance of each room lawfully used for sleeping purposes.

6.9.2 – Smoke & CO Detectors
Smoke & CO Detectors 2
CO DETECTOR NOT SECURED

Carbon monoxide detectors were not secured properly. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage within a specified distance of each room lawfully used for sleeping purposes.

 9 – Bathroom
9.5.1 – Floors
Floors 1
FLOOR NOT SEALED AT EDGE

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.5.1 – Floors
Floors 3
FLOOR NOT SEALED AT EDGE

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

 14 – Water Heating Equipment
14.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

 15 – Heating
15.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.