21055 E Quincy Dr
Aurora, CO 80013
The corner stud was split/damaged in the primary bedroom. Plumbing plates appeared to be installed in the appropriate locations and were in serviceable form. Any deficiencies will be listed later in this report.
The wall stud was split/damaged in areas near the main entrance. Plumbing plates appeared to be installed in the appropriate locations and were in serviceable form. Any deficiencies will be listed later in this report.
The windows did not have tempered glass installed for safety in the 1st floor rear room and upstairs front bedroom. Tempered glass is required if the bottom of the window is less than 18 inches above the floor or ground. A qualified contractor should evaluate and repair or replace as necessary.
The window in the upstairs front bedroom was installed upside down/and did not match the configuration of the other window. A qualified contractor should evaluate and repair or replace as necessary.
The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. A qualified contractor should evaluate and repair or replace as necessary.
No soil cover was installed at the time of the inspection. Soil covers help reduce humidity levels in crawlspaces by limiting moisture evaporation into the air from the soil. Reducing humidity levels can help reduce the chances for mold growth and deterioration of structural components. A qualified contractor should evaluate and install a soil cover as necessary.
There is no insulation on the crawlspace exterior walls or floor system. Heat loss can occur more on this property than on one that is properly insulated. A qualified contractor should evaluate and install as necessary.