2 – Interior, Doors, Windows
2.3.1 – Floors
Floors 1
CRACKED/DAMAGED TILE

The tile floor was cracked/damaged.  A qualified contractor should evaluate and repair or replace as necessary.

2.4.1 – Doors
Doors 1
DIFFICULT TO SLIDE

The closet door was very difficult to slide on the track.  A qualified contractor should evaluate and repair or replace as necessary.

2.4.2 – Doors
Doors 2
NOT LOCKING

The door did not lock properly.  A qualified contractor should evaluate and repair or replace as necessary.

2.5.1 – Windows
NOT FUNCTIONAL

The window was not considered a functional window.  A qualified contractor should evaluate and repair or replace as necessary. Bedroom main level

2.5.2 – Windows
Windows 1
SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

2.6.1 – Electrical Outlets
Electrical Outlets 1
LOOSE – OUTLET

An electrical outlet was loose in the wall. A qualified contractor should evaluate and repair or replace as necessary.

2.6.2 – Electrical Outlets
Electrical Outlets 2
MISSING – FACEPLATE

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

2.8.1 – Stairways & Railings
Stairways & Railings 1
SPINDLE SPACING OVER 4″

At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary.

2.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
CO DETECTOR MISSING

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that have a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper levels.

2.9.2 – Smoke & CO Detectors
Smoke & CO Detectors 2
SMOKE DETECTOR MISSING

The smoke detector was missing. A qualified person should replace them as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

 3 – Kitchen
3.5.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinets over the years.

A qualified contractor should evaluate and repair or replace as necessary.

3.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
FLEX PIPE

The sink drain line had a flex pipe used as part of the drain line. Flexible drain lines can smell, clog, leak or fail. Flex lines design includes multiple folds in which moisture may become trapped and mold may grow.  A qualified contractor should evaluate and repair or replace as necessary.

3.10.2 – Drain Waste and Vent System
Drain Waste and Vent System 2
LEAKING

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

3.12.1 – Food Waste Disposer
Food Waste Disposer 1
MISSING WIRING CLAMP

The food waste disposer was missing the wiring connector (clamp and bushing).  A qualified contractor should evaluate and repair or replace as necessary.

3.12.2 – Food Waste Disposer
Food Waste Disposer 2
NOT WORKING

The food waste disposer was not working at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

3.13.1 – Dishwasher
Dishwasher 1
THE DRAIN LINE WAS NOT PROPERLY INSTALLED

The dishwasher drain line was not properly installed and was lacking either an air gap or a high loop.  A qualified contractor should evaluate and repair or replace as necessary.

3.14.1 – Range/Oven/Cooktop
Range/Oven/Cooktop 1
LOOSE ELEMENT

Qualified Contractor evaluate repair and replace as necessary.

3.17.1 – Refrigerator
DAMAGED

The refrigerator was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

 4 – Laundry
4.4.1 – Exhaust Fan
NO VENT NO WINDOW

The laundry room did not have an exhaust fan or an openable window. A qualified contractor should evaluate, then repair or replace as advised.

 6 – Bathroom
6.2.1 – Doors
Doors 1
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Exhaust Fan
Exhaust Fan 1
DIRTY

The bathroom exhaust fan was very dirty and possibly clogged.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE DAMAGE-WALLS

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinets over the years.

A qualified contractor should evaluate and repair or replace as necessary.

6.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CRACKED/DAMAGED – SINK

The sink was cracked or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

6.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
LOOSE IN WALL – SHOWER ARM

A shower supply arm was loose in the wall.  This will cause caulking/sealant to deteriorate at an accelerated rate and may allow water to enter the wall. Over time, this could potentially put added stress on the plumbing connections and develop a leak. Recommend a qualified contractor evaluate and repair or replace it as necessary.

6.12.3 – Plumbing Fixtures
Plumbing Fixtures 3
WATER NOT DIVERTED

The shower diverter did not divert all of the water to the shower and a stream of water passed through the bathtub spout when the shower was on.  A qualified contractor should evaluate and repair or replace as necessary.

6.12.4 – Plumbing Fixtures
Plumbing Fixtures 4
SEAL TUB SPOUT

The tub spout should be sealed at the wall to prevent moisture intrusion into the wall component. A qualified contractor should evaluate and then repair or replace as advised.

6.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – CORNERS AND FLOOR

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

6.14.2 – Tub, Shower Area
Tub, Shower Area 2
SIGNS OF REPAIR.
 7 – Bathroom 2
7.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE DAMAGE-WALLS

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinets over the years.

A qualified contractor should evaluate and repair or replace as necessary.

7.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
DRIP-TUB WHEN OFF

The tub spout drips when off.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
SPINS – TUB/SHOWER CONTROL

The shower/tub control lever or knob did not have a lever stop at the off position and continually spins.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.3 – Plumbing Fixtures
Plumbing Fixtures 3
WATER NOT DIVERTED

The shower diverter did not divert all of the water to the shower and a stream of water passed through the bathtub spout when the shower was on.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.4 – Plumbing Fixtures
Plumbing Fixtures 4
SEAL TUB SPOUT

The tub spout should be sealed at the wall to prevent moisture intrusion into the wall component. A qualified contractor should evaluate and then repair or replace as advised.

7.13.1 – Toilets
Toilets 1
LOOSE-TOILET TO TANK

The toilet was loose at the tank-to-toilet connection.  A qualified contractor should evaluate and repair or replace as necessary.

7.14.1 – Tub, Shower Area
Tub, Shower Area 1
SEALANT – MULTIPLE AREAS

Some caulking and/or grout in the tub & shower area was missing, loose, old, or poorly done.  Recommend a qualified contractor evaluate and re-seal as needed.

 9 – Exterior – Condo/Townhome
9.1.1 – Exterior Doors
Exterior Doors 1
DAMAGE – FRAME

The door frame appears to be damaged. This is possibly from excessive force such as ramming the door when locked, or from heavy usage. Recommend a qualified contractor to evaluate and repair or replace as necessary.

9.2.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
DRIPS AT KNOB

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

9.3.1 – Sump Pump Discharge Pipe
Sump Pump Discharge Pipe 1
DISCHARGE TOO CLOSE

The sump pump discharge pipe did not terminate far enough away from the foundation. Erosion can continue or become worse if not corrected possibly leading to water intrusion. This condition may cause problems by introducing excessive amounts of moisture to the soil near the foundation. A qualified contractor should evaluate and install a proper extension, to properly route drainage away from the foundation, usually at least 6 feet.

9.4.1 – Railings & Handrails
Railings & Handrails 1
LOOSE – HANDRAIL

The guard/handrail was loose and should be secured. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Plumbing
10.1.1 – Main Water Shut-Off Valve
Main Water Shut-Off Valve 1
CORRODED – VALVE

The main water shutoff valve was corroded.

The valve is not and was not operated during the scope of a home inspection.

Recommend a qualified contractor should evaluate and repair or replace as necessary.

 11 – Electrical
11.2.1 – Distribution Panels
Distribution Panels 1
CORROSION, WATER – CABINET

Indications of water intrusion, rust, and corrosion inside the electrical panel cabinet. A qualified contractor should evaluate and repair or replace as necessary.

11.2.2 – Distribution Panels
Distribution Panels 2
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power to.

Recommend a qualified contractor to verify the breakers and accuracy of any existing labeling as necessary.

11.2.3 – Distribution Panels
Distribution Panels 3
MISSING – MANUFACTURERS LABEL

The manufacturer’s label was missing, partial, or illegible on the electrical service panel. The manufacturer’s label typically provides information describing the main panel such as the name of the panel manufacturer, the panel model number, the panel amperage rating, limitations related to the environment in which the panel was designed to be installed, and grounding/bonding information for that particular model. The Inspector was unable to confirm the existence of proper conditions when confirmation would require information taken from this missing label.

 12 – Water Heating Equipment
12.2.1 – Water Shut-Off
Water Shut-Off 1
CORRODED – PIPE FITTINGS

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

12.3.1 – Pipe Connections
Pipe Connections 1
MISSING FLEX TUBING

The piping to the water heater is missing flex tubing to prevent the piping from breaking in case the concrete floor heaves or settles.

12.8.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
MISSING – PIPE

The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

 13 – Heating
13.2.1 – Exhaust Flue
Exhaust Flue 1
INADEQUATE SLOPE

The heating system exhaust flue had a negative or inadequate slope which could allow the products of combustion to leak into the living space. Furnace exhaust flues should slope upward at a minimum of ¼-inch per foot.

A qualified contractor should evaluate and repair or replace as necessary.

13.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

The fresh air supply is recommended by manufacturers for the efficient operation of fuel-burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

13.6.1 – Cabinet
Cabinet 1
DAMAGED

The cabinet showed signs of damage either to the inside or the outside of the cabinet. Recommend having a qualified contractor evaluate and repair or replace as necessary.

13.7.1 – Condensate
SIGNS OF LEAKING

The condensation drain components for the HVAC system were leaking or showing signs of the previous leaking. A qualified contractor should evaluate and repair or replace as necessary.

13.8.1 – Ductwork
Ductwork 1
DUCTS NOT SEALED

Air supply ducts were not sealed. Ideally, all ducts are sealed with mastic in order to be more energy-efficient. A qualified contractor should evaluate and repair as necessary.

13.9.1 – Air Filter
Air Filter 1
NOT SECURED

The HVAC system air filter was not properly secured. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

13.9.2 – Air Filter
Air Filter 2
VERY DIRTY

The HVAC system air filter was very dirty or clogged. This condition reflects a lack of regular maintenance of the HVAC system. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the heating and cooling system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

13.10.1 – Blower
THE SAFETY SWITCH DID NOT WORK

The safety switch located at the panel for the air circulating blower fan for the furnace did not operate or function at the time of inspection. A blower cabinet safety switch is meant to shut off the furnace when the blower cabinet cover is removed as a safety precaution. Correction and further evaluation are recommended.

 14 – Cooling
14.1.1 – Cooling System Information
Cooling System Information 1
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

14.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

14.3.1 – AC Compressor
AC Compressor 1
COIL FINS DAMAGED

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

14.7.1 – Evaporator Coils
Evaporator Coils 1
SIGNS OF LEAKING, CORROSION

Signs of leaking, corrosion, or rusting were present at the visible refrigerant lines connected to the evaporative coil. Leaking from this location may possibly have a compounded effect on the components beneath it which typically includes the furnace heat exchanger. Delays or failure to correct this issue may cause extended damage. Recommend a qualified contractor to evaluate and repair or replace as needed.

 15 – Structural Crawlspace
15.2.1 – Soil Vapor Barrier
Soil Vapor Barrier 1
NO BARRIER

No soil cover was installed at the time of the inspection. Soil covers help reduce humidity levels in crawlspaces by limiting moisture evaporation into the air from the soil. Reducing humidity levels can help reduce the chances of mold growth and deterioration of structural components. A qualified contractor should evaluate and install a soil cover as necessary.

15.6.1 – Insulation
Insulation 1
INSULATION NEEDED

There is no insulation on the crawlspace exterior walls or floor system. Heat loss can occur more on this property than on one that is properly insulated. A qualified contractor should evaluate and install as necessary.

15.8.1 – Electrical in Crawlspace
LIGHT NOT WORKING

The light fixture in the crawlspace was not working. A qualified contractor should evaluate and repair or replace as necessary.

15.9.1 – Plumbing in Crawlspace
Plumbing in Crawlspace 1
LEAKING – DRAIN PIPES

Drain pipes in the crawlspace were leaking in areas at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.