3 – Attic, Insulation and Ventilation
3.1.1 – Attic Access
Attic Access 1
NOT FINISHED
NOT COMPLETELY FINISHED NEEDS A LITTLE MORE PAINT

Attic hatch not finished at time of inspection. Recommend a qualified contractor evaluate further once hatch is installed.

4 – Exterior
4.10.1 – Window Wells
Window Wells 1
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
NEW CONSTRUCTION

The landscaping is not complete on new construction. suggest completion of landscaping to prevent soil erosion.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
EXTENSIONS NOT POSITIONED PROPERLY

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor evaluate and repair or replace as necessary.

5 – Attached Garage
5.5.1 – Vehicle Door
Vehicle Door 1
DAMAGE – WEATHER STRIPPING
THE WEATHERSTRIPPING AT THE BOTTOM EDGE OF THE DOOR IS LOOSE

The weather stripping at the garage door is damaged or insufficient.

A qualified contractor should evaluate and repair or replace as needed.

5.6.1 – Door Opener
Door Opener 1
NEEDS ADJUSTMENT
LIMITS NEED TO BE ADJUSTED ON THE GARAGE DOOR OPENER TO ELIMINATE THE SAG OF THE CHAIN

The garage door overcloses/overopens. Recommend a qualified contractor evaluate and repair or replace as needed.

6 – Interior, Doors, Windows
6.8.1 – Stairways & Railings
Stairways & Railings 1
HORIZONTAL RAILINGS

At the interior stairs, the handrail hand horizontal railings.  This creates a climbing risk for children.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.14.1 – Tub, Shower Area
Tub, Shower Area 1
Tub, Shower Area 2
CAULK – CORNERS AND FLOOR

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

9.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT
2ND FLOOR

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

10 – Bathroom 2
10.5.1 – Floors
Floors 1
FLOOR NOT SEALED AT EDGE

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

11 – Bathroom 3
11.5.1 – Floors
Floors 2
MISSING/DAMAGED GROUT
PRIMARY BATHROOM 3RD FLOOR

The tile floor had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

11.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – CORNERS AND FLOOR
PRIMARY 2ND FLOOR BATHROOM

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

11.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT
2ND FLOOR

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

13 – Bathroom 5
13.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 2
WATER NOT HOT
1ST FLOOR

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

15 – Plumbing
15.6.1 – Gas Piping
Gas Piping 1
Gas Piping 2
GAS LEAK
VERY MINOR GAS LEAK BACK BASEMENT

Gas piping in this home had a gas leak that was detected at the location indicated in the photo. Immediate repair by a qualified plumbing contractor is recommended. . A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16 – Water Heating Equipment
16.13.1 – Water Temperature
Water Temperature 1
Water Temperature 2
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

17 – Duel AC Cooling
17.1.1 – Cooling System Information
SERVICING RECOMMENDED
YEARLY SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

17.6.1 – Cooling System Operation

Cooling System Operation 1

Cooling System Operation 2

DID NOT PRODUCE COOLED AIR
2ND FLOOR

The cooling system turned on but did not operate as expected by producing adequate conditioned cooled air. An ambient air test was performed to determine if the difference in temperatures of the supply and return air was between 14 degrees and 22 degrees. A qualified contractor should evaluate and repair/replace as necessary.