2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.2.2 – Roof Covering
Roof Covering 2
DEGRANULATED

Some of the shingles appeared to be de-granulated in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
SPALLING

The driveway surface was spalling in areas. This condition will continue to degrade if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.3.1 – Garage Door Exterior
Garage Door Exterior 1
GAP AROUND DOOR

The door had an opening that was too wide leaving a gap or daylight around the door.  A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Walkways
Walkways 1
CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.2 – Walkways
Walkways 2
HEAVING AND/OR SETTLING

The walkway(s) showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.3 – Walkways
Walkways 3
SIGNS OF REPAIRS

Signs of repairs were present in the walkway(s) in areas. Recommend asking current homeowner for more information, and if repairs appear to be of poor quality it is recommended to have a qualified contractor evaluate further for any additional repairs necessary.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
ERODED GRADE

Grade has eroded or was poorly back-filled near the foundation wall, patio, or stairway. This may allow moisture to pool near the structure, and this may allow significant cracking if not corrected.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
DRIPS AT KNOB

The outside water faucet drips at the knob when turned on. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
MISSING – EXTENSIONS

Downspout(s) are missing the proper 6 ft. extensions. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.21.2 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 2
RECONNECT TO DRAIN

Downspout(s) need reconnecting to existing drain line. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. When moisture is introduced to the foundation it could also cause possible mold growth. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5 – Attached Garage
5.3.1 – Ceiling, Walls & Firewalls
Ceiling, Walls & Firewalls 1
DAMAGE – CEILING

The ceiling in the garage was damaged.

Recommend a qualified contractor evaluate and repair or replace as needed.

5.3.2 – Ceiling, Walls & Firewalls
Ceiling, Walls & Firewalls 2
DAMAGE – WALL

An interior wall in the garage was damaged.

Recommend a qualified contractor evaluate and repair or replace as needed.

5.4.1 – Floor
Floor 1
CRACKING – COMMON

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor evaluate and repair or replace as needed.

6 – Interior, Doors, Windows
6.3.1 – Floors
Floor 2
WEAR AND TEAR

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

7 – Kitchen
7.4.1 – Floors
Floor 3
WEAR AND TEAR

The floors showed signs of minor damage and wear – particularly in high traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.4.1 – Ceilings & Walls
Ceilings & Walls 1
NAIL POPS-CEILINGS

There were “nail pops” visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

10 – Bathroom 2
10.13.1 – Toilets
Toilets 1
LOOSE AT THE FLOOR

The toilet was loose at the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. Loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
MISSING/DAMAGED GROUT

Tiles on the wall in the bath/shower area had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

10.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

13 – Water Heating Equipment
13.6.1 – Combustion Air Supply
Combustion Air Supply 1
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

14 – Heating
14.9.1 – Air Filter
Air Filter 1
DIRTY

The HVAC system air filter was dirty. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

18 – Structural Crawlspace
18.3.1 – Moisture Intrusion
Moisture Intrusion 1
POSSIBLE MOLD

Evidence of a possible mold like substance was observed.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555