3 – Attic, Insulation and Ventilation
3.2.1 – Attic Access 2
Attic Access 2 1
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

3.4.1 – Attic Moisture Intrusion
Attic Moisture Intrusion 1
WATER INTRUSION – VENT PIPE

Visible signs of water intrusion in the attic are present on a vent pipe. Water intrusion can lead to more costly repairs and increase damage if not corrected. The extent of intrusion or how often it occurs could not be determined. A qualified contractor should evaluate and repair or replace as necessary.

3.5.1 – Insulation in Attic
Insulation in Attic 1
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor evaluate and repair or replace as needed.

4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.3 – Driveways
Driveways 3
PITTED

The driveway surface was pitted in areas. A qualified contractor should evaluate and repair or replace as necessary.

4.6.1 – Exterior Doors

Exterior Doors 1

PEELING PAINT

An entry door had areas of peeling paint.  A qualified contractor should evaluate and repair or replace as necessary.

4.9.1 – Windows

Windows 1

Windows 2

DAMAGED – SCREEN

One or more window screens were damaged or deteriorated.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.10.1 – Window Wells
Window Wells 1
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Walkways

Walkways 1

CRACKING – MINOR
Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
4.11.2 – Walkways
Walkways 2
CRACKING – MODERATE

There were signs of moderate cracking on the walkway(s) in areas. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

4.11.3 – Walkways
Walkways 3
HEAVING AND/OR SETTLING

The walkway(s) showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose or it can no longer support the weight causing it to sink or crack.

  • This causes cracks in the concrete.
  • This creates trip hazards that could result in injury.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
Vegetation, Grading & Drainage 3
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

4.13.1 – Sprinkler System Supply Line
Sprinkler System Supply Line 1
MINOR CORROSION

Pipes or valves had minor surface corrosion at the sprinkler supply line. Monitoring and contacting a qualified professional to further evaluate for repairs is recommended

4.13.2 – Sprinkler System Supply Line
Sprinkler System Supply Line 2
VALVES NOT PRESENT

The exterior isolation valves were not present. The sprinkler system valves were not operated or activated. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.17.1 – Exterior Foundation Wall

Exterior Foundation Wall 1

Exterior Foundation Wall 2
CRACK – SETTLEMENT

The exterior foundation wall had settlement crack(s.) A qualified contractor should evaluate and repair or replace as necessary. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540

4.19.1 – Decks & Balconies
Decks & Balconies 1
BOWED – STRUCURE

A support post or floor joist was bowed at the deck. A qualified contractor should evaluate and repair or replace as necessary.

4.19.2 – Decks & Balconies
Decks & Balconies 2
CONTACT WITH GROUND

A wood support post or wood portion of the deck was in direct contact with the ground/dirt. The wood should be pressure treated and ideally be: placed in a metal bracket and/or cement casing, and have clearance from the ground level. Wood in direct contact with dirt will wick up ground moisture and deteriorate at an accelerated rate if routine maintenance is not kept.

Recommend a qualified contractor evaluate and repair or replace as needed.

4.19.3 – Decks & Balconies
Decks & Balconies 3
DETERIORATED – FLOORING

There were deteriorated flooring components visible at the deck. Depending on the severity of the deterioration, use of the deck should be cautiously monitored.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.4 – Decks & Balconies
Decks & Balconies 4
LOOSE – FLOOR BOARD(S)

Loose board(s) were visible on the flooring at the deck.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.5 – Decks & Balconies
Decks & Balconies 5
MISSING – LEDGER FLASHING

Flashing was missing at the ledger board. This flashing problem may allow water to enter into the wall cavity or building components. A qualified contractor should evaluate and repair or replace as necessary.

4.20.1 – Railings & Handrails
Railings & Handrails 1
DETERIORATED
BACK

A handrail was deteriorated or damaged at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
EXTENSIONS NOT POSITIONED PROPERLY

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.21.2 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 2
RECONNECT DOWN SPOUTS AND EXTENSION

Downspout(s) need to have extensions reconnected. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. When moisture is introduced to the foundation it could also cause possible mold growth. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
OPENS OVER STEP
GARAGE

The door swings over the top step of the stairway when opened.  This can lead to a fall and is considered a safety hazard.  A qualified contractor should evaluate and repair or replace as necessary.

5.3.1 – Ceiling, Walls & Firewalls
Ceiling, Walls & Firewalls 1
DAMAGE – CEILING
GARAGE

The ceiling in the garage was damaged.

Recommend a qualified contractor evaluate and repair or replace as needed.

5.4.1 – Floor
Floor 1
CRACKING – COMMON

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor evaluate and repair or replace as needed.

5.4.2 – Floor
Floor 2
Floor 3
HEAVING/SETTLING

Indications of movement from heaving/settling of the concrete floor were present in the garage. Significant movement may be a compromise the structural integrity of the foundation or structure of the garage which only a qualified structural engineer could comment after further analysis.

Recommend a qualified structural engineer inspect further and provide a professional opinion related to this observation.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-400-8148

5.5.1 – Vehicle Door
Vehicle Door 1
WEAK SPRINGS

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.

Recommend a qualified contractor evaluate and repair or replace as necessary.

6 – Interior, Doors, Windows
6.2.1 – Ceilings & Walls
Ceilings & Walls 1
ASBESTOS CEILING
THROUGHOUT PROPERTY

The property had ceiling materials that may contain asbestos. Ceiling tiles or popcorn texture were manufactured or installed using asbestos as late as the early 90s.

In the past, asbestos fibers were added during the production to strengthen and increase durability. Materials that contain asbestos, when intact and in good condition, is generally considered non-friable and is not hazardous. Heat, water, weathering or aging can weaken asbestos materials to the point where it is considered friable. Friable material includes any material containing more than 1 percent asbestos that can be crumbled, pulverized or reduced to powder with hand pressure. This includes previously non-friable material which has been damaged to the extent that it may be crumbled, pulverized or reduced to powder by hand pressure and can also be made friable during its removal. Friable materials can release asbestos fibers into the air. Once in the air, asbestos fibers present a health hazard to people who inhale those fibers.

6.2.2 – Ceilings & Walls

Ceilings & Walls 2

CRACKING AROUND WINDOW

There was cracking around some windows on the interior (where the window meets the wall).  A qualified contractor should evaluate and repair or replace as necessary.

6.2.3 – Ceilings & Walls

Ceilings & Walls 3

Ceilings & Walls 2

MINOR CRACKS-CEILING

Minor cracking was visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

6.2.4 – Ceilings & Walls

Ceilings & Walls 3

Ceilings & Walls 4

TAPE PULLING

The drywall showed pulling or wrinkling of the drywall tape at the corner which may reflect structural movement in that area.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Floors
Floors 1
DAMAGED – FLOOR COVERING
THROUGHOUT PROPERTY

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor evaluate and repair or replace as needed.

6.3.2 – Floors
Floors 2
FLOOR SQUEAKS
2ND FLOOR

The floor squeaks when stepped on.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.1 – Doors

Doors 1

Doors 2

MISSING – DOOR

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary.

6.4.2 – Doors

Doors 3

RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

6.6.1 – Electrical Outlets

Electrical Outlets 1

MISSING – FACEPLATE

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

6.7.1 – Electrical Fixtures & Switches

Electrical Fixtures & Switches 1

Electrical Fixtures & Switches 2
Electrical Fixtures & Switches 3
NOT WORKING – BULB(S)
MULTIPLE THROUGHOUT PROPERTY

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

6.8.1 – Stairways & Railings
Stairways & Railings 1
SPINDLE SPACING OVER 4″

At the interior stairs, the handrail had spacing between components that were too far apart. Spacing of more than 4 ” could allow a child or pet to fall through. A fall or injury could occur if not corrected.  A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
THROUGHOUT PROPERTY

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper level.

6.9.2 – Smoke & CO Detectors
SMOKE DETECTOR MISSING
BASEMENT MECHANICAL ROOM

The smoke detector was missing. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

6.9.3 – Smoke & CO Detectors

Smoke & CO Detectors 1

SMOKE DETECTOR OLD

Some of the smoke detectors appeared to be old and beyond their expected life. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

7 – Kitchen
7.4.1 – Floors
Floors 1
FLOOR DAMAGED

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor evaluate and repair or replace as needed.

7.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.2 – Cabinets & Counters
Cabinets & Counters 2
DAMAGED – CABINET

The base cabinet was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.3 – Cabinets & Counters
Cabinets & Counters 3
DAMAGED – CABINET FLOOR
EXCESSIVE DIRT AND DEBRIS MAY BE HIDING ADDITIONAL DAMAGES OTHER THAN SURFACE WHERE IN TEAR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years.

A qualified contractor should evaluate and repair or replace as necessary.

7.5.4 – Cabinets & Counters
Cabinets & Counters 4
POSSIBLE MOLD
KITCHEN

Evidence of a possible mold like substance was observed.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555

7.6.1 – Electrical Outlets
Electrical Outlets 1
NO GFCI PROTECTION
KITCHEN

No ground fault circuit interrupter (GFCI) protection was provided for kitchen electrical outlets. Although GFCI protection of kitchen circuits may not have been required at the time in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing kitchen electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary.

7.6.2 – Electrical Outlets
OUTLET HOT AND NEUTRAL REVERSED
MICROWAVE OVEN PLUG

One or more electrical outlet(s) were wired incorrectly with the hot and neutral wires being reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created as there is still electricity running through the hot wire when the switch is off. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

7.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB

A fixture or bulb was not responding to switches at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Faucets Fixtures
Faucets Fixtures 1
FAUCET LEAKS AT MOUNT
KITCHEN

The sink faucet leaked around the mount.  A qualified contractor should evaluate and repair or replace as necessary.

7.10.1 – Drain Waste and Vent System
LEAKING

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.1 – Food Waste Disposer
Food Waste Disposer 1
DAMAGED

The food waste disposer was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

7.12.2 – Food Waste Disposer
Food Waste Disposer 2
LEAKS

The food waste disposer was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

7.15.1 – Range Hood
Range Hood 1
Range Hood 2
NOT WORKING

The exhaust vent fan was not operational at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

7.16.1 – Mounted Microwave
Mounted Microwave 1
Mounted Microwave 2
NOT WORKING

The microwave was not functioning at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

8 – Laundry
8.5.1 – Ceilings & Walls
Ceilings & Walls 1
SAGGING DRYWALL

The drywall on the ceiling was sagging.  A qualified contractor should evaluate and repair or replace as necessary.

8.9.1 – Electrical Outlets
Electrical Outlets 1
GFCI PROTECTION NOT PRESENT
BASEMENT BEDROOM LAUNDRY AREA

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.4.1 – Ceilings & Walls

Ceilings & Walls 1

TAPE PULLING
2ND FLOOR GUEST BATHROOM

The drywall showed pulling or wrinkling of the drywall tape at the corner which may reflect structural movement in that area.  A qualified contractor should evaluate and repair or replace as necessary.

9.5.1 – Floors
Floors 1
FLOOR DAMAGED

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor evaluate and repair or replace as needed.

9.7.1 – Electrical Outlets
Electrical Outlets 1
WIRED TO LIGHT
2ND FLOOR BATHROOM

An electrical outlet was wired to a light fixture and is not separate.  A qualified contractor should evaluate and repair or replace as necessary.

9.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

9.9.2 – Cabinets & Counters
Cabinets & Counters 2
WORN FINISH
EXCESSIVELY WARREN FINISH AN ABSOLUTELY FILTHY

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

9.10.1 – Drain Waste and Vent System

Drain Waste and Vent System 1

CLOGGED/SLOW – TUB/SHOWER DRAIN

The tub/shower drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

9.10.2 – Drain Waste and Vent System
Drain Waste and Vent System 2
NOT WORKING – SINK STOPPER

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

9.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CHIPPED – SINK

The sink finish was chipped or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

9.14.1 – Tub, Shower Area
Tub, Shower Area 1
SEALANT – MULTIPLE AREAS

Some caulking and/or grout in the tub & shower area was missing, loose, old, or poorly done.  Recommend a qualified contractor evaluate and re-seal as needed.

9.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT
2ND FLOOR

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

10 – Bathroom 2
10.2.1 – Doors
Doors 1
NOT LATCHING SECURELY
PRIMARY BATHROOM

An interior door door did not latch properly. This may be that it was not shimmed properly at the jamb (too wide) or the strike plate was not in the correct position.

A qualified contractor should evaluate and repair or replace as necessary.

10.5.1 – Floors
Floors 1
WEAR AND TEAR
EXCESSIVE WEAR AND TEAR BORDERLINE DAMAGED

The floors showed signs of minor damage and wear – particularly in high traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

10.7.1 – Electrical Outlets
Electrical Outlets 1
NOT WORKING
PRIMARY BATHROOM

An electrical outlet was not working. A qualified contractor should evaluate and repair or replace as necessary.

10.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
PRIMARY BATHROOM

One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

10.8.2 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 2
OLD/ RUSTY

The light fixture was old and rusted.  A qualified contractor should evaluate and repair or replace as necessary.

10.9.1 – Cabinets & Counters
Cabinets & Counters 1
WORN FINISH
PRIMARY BATHROOM EXCESSIVE WEAR AND TEAR

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

10.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
LEAKING
PRIMARY BATHROOM

The sink drain pipe was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.2 – Drain Waste and Vent System
Drain Waste and Vent System 2
MISSING – SINK DRAIN STOPPER
PRIMARY BEDROOM

The sink drain stop was missing, damaged or did not operate properly.  A qualified contractor should evaluate and repair or replace as necessary.

10.13.1 – Toilets
Toilets 1
LOOSE AT THE FLOOR
PRIMARY BATHROOM

The toilet was loose at the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. Loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
SEALANT – MULTIPLE AREAS
PRIMARY BATHROOM

Some caulking and/or grout in the tub & shower area was missing, loose, old, or poorly done.  Recommend a qualified contractor evaluate and re-seal as needed.

11 – Bathroom 3
11.2.1 – Doors
Doors 1
MISSING – DOOR

The door was missing.  A qualified contractor should evaluate and repair or replace as necessary.

11.5.1 – Floors
Floors 1
FLOOR DAMAGED

There appeared to be some damage to the interior flooring in areas. Recommend a qualified contractor evaluate and repair or replace as needed.

11.7.1 – Electrical Outlets
Electrical Outlets 1
NO GFCI PROTECTION
BASEMENT BATHROOM LAUNDRY AREA

No ground fault circuit interrupter (GFCI) protection was provided for the bathroom electrical outlets. Although GFCI protection of bathroom circuits may not have been required at the time of in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing bathroom electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary.

11.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
BASEMENT LAUNDRY AREA BATHROOM

One or more bulbs was not working in the bathroom at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

11.9.1 – Cabinets & Counters
Cabinets & Counters 1
WORN FINISH

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor evaluate and repair or replace as needed.

11.14.1 – Tub, Shower Area
Tub, Shower Area 1
SEALANT – MULTIPLE AREAS

Some caulking and/or grout in the tub & shower area was missing, loose, old, or poorly done.  Recommend a qualified contractor evaluate and re-seal as needed.

12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too.

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

12.3.1 – Main Service Shut-Off
Main Service Shut-Off 1
NO DISCONNECT – OLD PANEL

This panel required more than 6 hand movements to shut off power to all breakers since there was not a main electrical service shut-off breaker installed at the distribution panel.

Some older panel designs did not include a main power shut-off switch. Shutting off power to all breakers should not require more than 6 hand movements in the main electrical panel. Although homes are only required to comply with codes that were in effect at the time they were originally constructed.

Recommend that a main disconnect be installed by a qualified electrical contractor.

13 – Plumbing
13.2.1 – Water Supply
Water Supply 1
CORRODED – MAIN SUPPLY LINE

The main water supply line material is considered what enters the home from the city or well.

Excessive surface corrosion was present at the time of inspection. Corrosion or rust will lead to a leak or pipe burst if not corrected. There could be leaks not visible, or within the ground.

Recommend a qualified contractor evaluate and repair or replace as needed.

14 – Water Heating Equipment
14.1.1 – General Information
General Information 1
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

14.3.1 – Pipe Connections
Pipe Connections 1
MISSING FLEX TUBING

The piping to the water heater is missing flex tubing to prevent the piping from breakage in case the concrete floor heaves or settles.

14.6.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

14.9.1 – Exterior Condition/Leakage
Exterior Condition/Leakage 1
RUSTED

The water heating equipment was rusted/corroded showing signs of previously leaking. A qualified contractor should evaluate and repair or replace as necessary.

14.12.1 – Operation & Response to Controls
Operation & Response to Controls 1
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

14.13.1 – Water Temperature
Water Temperature 1
Water Temperature 2
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

16 – Heating
16.1.1 – Heating System Information
Heating System Information 1
BEYOND TYPICAL LIFE EXPECTANCY
1979 PRODUCTION

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

16.3.1 – Combustion Air Supply
NOT PRESENT

The combustion air supply for this appliance was not present. A qualified contractor should evaluate and make necessary corrections according to current standards.

Fresh air supply is recommended by manufacturers for efficient operation of fuel burning appliances. Years ago, the air could come from inside or outside the building, however, more recent standards prefer for combustion air to come from the outside only.

16.8.1 – Ductwork
Ductwork 1
DUCTS NOT SEALED

Air supply ducts were not sealed. Ideally all ducts are sealed with mastic in order to be more energy-efficient. A qualified contractor should evaluate and repair as necessary.

16.12.1 – Heating System Ignition & Operation
Heating System Ignition & Operation 1
FLAMES

The heating system did fire and appeared to be in serviceable condition at the time of the inspection. However, the appearance of the flames during operation indicated that gas combustion was not correct. Cleaning, servicing and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.

17 – Structural Basement
17.2.1 – Basement Floor
Basement Floor 1
Basement Floor 2
Basement Floor 3
CRACKED – COMMON
THROUGHOUT THE BASEMENT LIVING AREA AND BEDROOMS

The concrete floor in the basement was cracked in areas. These cracks appear to be common cracks indicating regular settlement or heaving, but not necessarily structural problems. Recommend a qualified contractor to evaluate to make further recommendations and repair as necessary.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540

17.3.1 – Foundation Wall

Foundation Wall 1

Foundation Wall 2

MINOR CRACKS

There were minor to moderate cracks in the basement foundation wall. These cracks should be sealed to prevent moisture intrusion and monitored for further movement. Further analysis by a licensed structural engineer is recommended. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540

17.4.1 – Basement Interior Wall Structure
Basement Interior Wall Structure 1
BASEMENT WALLS NOT FLOATING

Basement walls were not constructed using a method which will allow for soil movement. This method is usually termed “floating” the walls and involves leaving a gap at the bottom of the wall so that vertical movement (heaving) of the concrete slab basement floor will not be transmitted to the rest of the property structure. Colorado has areas with expansive soils. Expansive soils are soils which increase to many times their original volume in response to increases in soil moisture content, creating forces which can easily damage property structural components such as foundations, floor slabs, flat work and interior and exterior wall coverings. Consider consulting with a qualified contractor before the expiration of your Inspection Objection Deadline to discuss options and costs for correction an/ or stabilization.