2 – Roof
2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

3 – Attic, Insulation and Ventilation

3.1.1 – Attic Access

Attic Access 1
DAMAGED HATCH

The attic access hatch was damaged. A qualified contractor should evaluate and repair or replace as necessary.

4 – Exterior
4.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
SPALLING

The driveway surface was spalling in areas. This condition will continue to degrade if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
Wall-Covering, Flashing & Trim 2
PAINTERS TAPE

Tape was left by the painters around the property.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
DAMAGED – SIDING

The siding and/or trim was damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.6.1 – Exterior Doors
Exterior Doors 1
MISSING – SCREEN DOOR

A screen door was missing at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.7.1 – Electrical Fixtures
Electrical Fixtures 1
DAMAGED – FIXTURE/COVER

The exterior light fixture or light cover was damaged. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

4.8.1 – Electrical Outlets
Electrical Outlets 1
GFCI – NOT ALL PROTECTED

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the exterior electrical outlets. Although GFCI protection of exterior circuits may not have been required at the time in which this property was built, modern building and safety standards now require them. This is a reflection of the current understanding of the potential hazards. The inspector recommends updating the existing exterior electrical circuits to include GFCI protection. A qualified contractor should evaluate and implement according to current standards.

4.11.1 – Walkways
Walkways 1
TRIP HAZARD – WALKWAY(S)

A trip hazard was present on the walkway(s) in areas.  This condition is a safety concern. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
LARGE TREES FOUNDATION

Consideration should be given to trimming or even removing large tree(s) located close to the structure. We suggest consultation with a tree specialist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 2
Vegetation, Grading & Drainage 3
Vegetation, Grading & Drainage 4
TREE BRANCHES OVER PROPERTY

Large trees near the house have branches which overhang the property. Falling branches due to conditions such as wood decay, high winds or heavy snow loads may cause injury, death or damage. Significant weakening of large branches by conditions such as core decay may not be visible by persons without special training. Consider having these trees evaluated by a qualified arborist. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

4.19.1 – Decks & Balconies
Decks & Balconies 1
Decks & Balconies 2
DETERIORATED – STRUCTURE

There were deteriorated structural components visible at the planters.

A qualified contractor should evaluate and repair or replace as necessary.

4.19.2 – Decks & Balconies
Decks & Balconies 3
IMPROPER FASTENERS – DECK

Some or all deck components were constructed using improper fasteners (ie nails or screws). Specific nails or screws must be used with proper shear force and withdrawal force ratings, and are generally galvanized 2 1/2 inch.

A qualified contractor should evaluate and repair or replace as necessary.

4.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
EXTENSIONS DENTED/DAMAGED

Downspout extensions were dented or damaged in some areas at the time of inspection. This condition can cause a blockage and potential build up of moisture intrusion into the soil next to the foundation walls. This in turn can potentially cause hydro-static pressure against the foundation walls and create adverse results. Recommend further evaluation by a qualified contractor to repair or replace.

5 – Interior, Doors, Windows
5.2.1 – Ceilings & Walls

Ceilings & Walls 1

DAMAGED – BASEBOARD TRIM

Baseboard trim was damaged at areas of the interior walls at the time of inspection.

Recommend a qualified contractor evaluate and repair or replace as needed.

5.3.1 – Floors

Floors 1

SEAMS WIDE/INCONSISTEN

The flooring had seams that were wide or inconsistent possibly indication loose flooring or poor installation.  A qualified contractor should evaluate and repair or replace as necessary.

5.3.2 – Floors

Floors 2

WET STAINS

The floor had wet stains indicating moisture intrusion did or does exist.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Doors
Doors 1
DAMAGED – DOOR

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

5.4.2 – Doors
Doors 2
RUBS FRAME

An interior door rubs at the door frame when closing. This may mean the door or frame is out of square or that hinges may not be installed properly.

A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Windows

Windows 1

BROKEN SEALS

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass was observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Windows

Windows 2

SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.3 – Windows
Windows 3
Windows 4
Windows 5
SEALANT DAMAGED AROUND FRAME

Sealant was damage deteriorated around the window. Recommend a qualified contractor repair or replace as necessary.

5.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
FAN- MISSING COVER

The fan cover was missing. A qualified contractor should evaluate and repair or replace as necessary.

5.7.2 – Electrical Fixtures & Switches

Electrical Fixtures & Switches 2

FLICKERING LIGHT

The light fixture flickered possibly indicating a loose connection at the switch or fixture.  A qualified contractor should evaluate and repair or replace as necessary.

5.7.3 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 3
LOOSE – LIGHT FIXTURE

The light fixture was loose. A qualified contractor should evaluate and repair or replace as necessary.

5.7.4 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 4

Electrical Fixtures & Switches 5

NOT WORKING – BULB(S)

One or more light bulbs were not working at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

5.7.5 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 6
FAN MISSING REMOTE

The ceiling fan did not respond to any wall switches. The fixture may be wired to be controlled by a remote but there was not remote available at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

5.9.1 – Smoke & CO Detectors
Smoke & CO Detectors 1
CO DETECTOR OLD

Carbon monoxide detector appears to be old. Any older detector should be replaced.

5.9.2 – Smoke & CO Detectors

Smoke & CO Detectors 2

SMOKE DETECTOR MISSING

The smoke detector was missing. A qualified person should replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

5.9.3 – Smoke & CO Detectors
Smoke & CO Detectors 3
SMOKE DETECTOR OLD

Some of the smoke detectors appeared to be old and beyond their expected life. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

6 – Kitchen
6.7.1 – Windows
Windows 1
SEALANT DAMAGED AROUND FRAME

Sealant was damage deteriorated around the window. Recommend a qualified contractor repair or replace as necessary.

6.9.1 – Faucets Fixtures
Faucets Fixtures 1
FAUCET LEAKED

The sink faucet leaked.  A qualified contractor should evaluate and repair or replace as necessary.

6.12.1 – Food Waste Disposer
Food Waste Disposer 1
MISSING WIRING CLAMP

The food waste disposer was missing the wiring connector (clamp and bushing).  A qualified contractor should evaluate and repair or replace as necessary.

6.17.1 – Refrigerator
Refrigerator 1
Refrigerator 2
WATER/ICE DISPENSER NOT OPERATIONAL

Although outside the scope of a general home inspection, the inspector noted the refrigerator ice and/or water dispenser was not working.  A qualified contractor should evaluate and repair or replace as necessary.

7 – Detached Garage
7.7.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

7.8.1 – Interior Outlets & Fixtures
Interior Outlets & Fixtures 1
GFCI – NOT ALL PROTECTED

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the garage electrical outlets. A qualified contractor should evaluate and implement according to current standards.

Although GFCI protection of garage circuits may not have been required at the time in which this property was built, GFCI protection is now required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage.

8 – Laundry
8.16.1 – Laundry Sink
Laundry Sink 1
LEAKING – DRAIN

The drain at the laundry sink was leaking at a connection at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

9 – Bathroom
9.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

10 – Bathroom 2
10.3.1 – Exhaust Fan
Exhaust Fan 1
TAPE ON COVER
12 – Plumbing
12.1.1 – Main Water Shut-Off Valve
Main Water Shut-Off Valve 1
CORRODED – VALVE

The main water shutoff valve was corroded.

The valve is not and was not operated during the scope of a home  inspection.

Recommend a qualified contractor should evaluate and repair or replace as necessary.

13 – Electrical
13.1.1 – Electric Meter & Base
Electric Meter & Base 1
METER BASE NOT SECURE

The electric meter base was loose at ground level. A qualified contractor should evaluate and repair or replace as necessary.

14 – Water Heating Equipment
14.1.1 – General Information
OLDER THAN 10 YEARS
2000

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

15 – Heating
15.1.1 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY
2000

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

15.6.1 – Cabinet
Cabinet 1
CONDENSATION LEAK

The furnace cabinet interior at the blower chamber had moisture damage from a condensation leak. A qualified contractor should evaluate and repair or replace as necessary.

15.9.1 – Air Filter
Air Filter 1
DIRTY

The HVAC system air filter was dirty. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

15.10.1 – Blower
Blower 1
BLOWER, CABINET DIRTY

The blower motor, wheel, and/or cabinet appeared to be dirty at the time of inspection. Blower fans/wheels are subjected to constant dirt, dust, and lint and can become overly dirty when not cleaned on a regular basis and even faster if the air filters are not changed regularly.

A qualified contractor should evaluate, clean, and service as necessary, and certify the unit is in good working order.

16 – Cooling
16.1.1 – Cooling System Information
BEYOND TYPICAL LIFE EXPECTANCY
2000

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

16.3.1 – AC Compressor
AC Compressor 1
AIR FLOW RESTRICTED

Air flow to the air-conditioner condenser coils was restricted by vegetation, dirt, or debris. The unit should be cleaned and anything restricting air flow in or around the air conditioner should be removed in order to maintain cooling system efficiency and avoid problems from overheating of the compressor.

16.3.2 – AC Compressor
AC Compressor 2
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16.4.1 – AC Service Disconnect
AC Service Disconnect 1
LOOSE CONDUIT

The service disconnect was loose at the unit. A qualified contractor should evaluate and repair or replace as necessary.

16.6.1 – Cooling System Operation
Cooling System Operation 1
Cooling System Operation 2
DID NOT PRODUCE COOLED AIR

The cooling system turned on but did not operate as expected by producing adequate conditioned cooled air. An ambient air test was performed to determine if the difference in temperatures of the supply and return air was between 14 degrees and 22 degrees. A qualified contractor should evaluate and repair/replace as necessary.

19 – Structural Basement
19.5.1 – Moisture Intrusion
Moisture Intrusion 1
MOISTURE INTRUSION

The visible areas of the basement showed signs of possible previous moisture intrusion and/or deterioration. A qualified contractor should evaluate and repair or replace as necessary.

20 – Fireplace or Stove
20.1.1 – Fireplaces Gas/LP
Fireplaces Gas/LP 1
GLASS CLOUDY

The glass at the fireplace had a cloudy appearance. A qualified contractor should evaluate and repair or replace as necessary.