2 – Roof
2.6.1 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 1
INADEQUATE CLEARANCE – ROOF

One or more combustion appliance exhaust flue(s) did not extend far enough above the roof. To ensure proper and safe operation, exhaust flues should extend at least 3 feet above the roof, and 2 feet above any portion of the roof within 10 feet (measured horizontally).  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.6.2 – Flue Gas Vent Pipes
Flue Gas Vent Pipes 2
DENTED/DAMAGED

The combustion exhaust flue was dented/damaged at the time of the inspection. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
Roof Drainage Systems 2
Roof Drainage Systems 3
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be a sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4 – Attic, Insulation and Ventilation 2 
4.4.1 – Insulation in Attic
Insulation in Attic 1
Insulation in Attic 2
Insulation in Attic 3
NOT UNIFORM

The insulation is not uniform: thicker in areas, thinner in areas, or possibly missing in some areas.

Recommend a qualified contractor evaluate and repair or replace as needed.

5 – Exterior 
5.2.1 – Driveways
Driveways 1
CRACKING – MINOR

Minor cracking was visible on the driveway in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
DAMAGE – SOFFIT

The soffit was damaged in one or more areas.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.10.1 – Window Wells
Window Wells 1
Window Wells 2
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

5.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
DENSE VEGETATION

Dense vegetation was present around the house in areas.  This condition limited and restricted my visual inspection.  Dense vegetation and landscaping up against or near the house foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning and some landscaping is recommended by a qualified contractor

5.12.2 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 3
NEGATIVE GRADING

The property had areas of neutral or negative drainage, which will route runoff from precipitation to the foundation.  Excessive moisture content in soil supporting the foundation can cause foundation and other structural damage from undermining, heaving or settling, depending on soil composition, moisture content and other conditions.The ground around the property should slope away from all sides, ideally 6 inches for the first 10 feet from the house foundation perimeter. Downspouts, surface gutters and drains should also be directing water away from the foundation. A qualified contractor should evaluate and repair as necessary according to current standards.

5.12.3 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 4
TREE LIMBS CONTACT ROOF

The tree limbs that are in contact with the roof or hanging near the roof should be trimmed. Evaluating trees lies beyond the scope of the general property inspection.

Recommend a qualified contractor evaluate and repair or replace as necessary.

5.14.1 – Exterior Faucets (Hose Bibs)
LEAKS AT ANTI-SIPHON

The exterior hose bib dripped from the anti-siphon when operated.

5.19.1 – Decks & Balconies
Decks & Balconies 1
PEELING PAINT – DECK

The exterior deck floor and/or other components were peeling paint. A qualified contractor should evaluate and repair or replace as necessary.

5.20.1 – Railings & Handrails
Railings & Handrails 1
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

6 – Attached Garage
6.4.1 – Floor
Floor 1
Floor 1
DETERIORATED

The concrete garage floor was deteriorated or eroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

6.5.1 – Vehicle Door
Vehicle Door 1
WEAK SPRINGS

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.

Recommend a qualified contractor evaluate and repair or replace as necessary.

6.7.1 – Electrical Outlets & Fixtures
Electrical Outlets & Fixtures 1
GFCI – NOT ALL PROTECTED

Ground Fault Circuit Interrupter (GFCI) protection was not provided for all the garage electrical outlets. A qualified contractor should evaluate and implement according to current standards.

Although GFCI protection of garage circuits may not have been required at the time in which this property was built, GFCI protection is now required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage.

6.9.1 – Stairs & Railings
Stairs & Railings 1
RISER TOO TALL, OVER 7 3/4″

The stair riser height is more than what is accepted for current safety standards.

The riser height maximum is 7 3/4 inches measured vertically between the stair treads. This poses a trip hazard.

Recommend a qualified contractor evaluate and repair or replace as needed.

7 – Interior, Doors, Windows

7.3.1 – Floors
Floors 1
CARPET LOOSE
MIDDLE BEDROOM

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

7.4.1 – Doors
Doors 1
Doors 2
MISSING – DOORSTOP

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

7.5.1 – Windows
Windows 1
Windows 2
Windows 3
SEALANT AROUND FRAME

The sealant was damaged, deteriorated or otherwise insufficient around the window. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

7.7.1 – Electrical Fixtures & Switches
FAN NOISY
MIDDLE BEDROOM

The ceiling fan was noisy when on.  A qualified contractor should evaluate and repair or replace as necessary.

7.8.1 – Stairways & Railings
LOOSE – HANDRAIL

At the interior stairs, the handrail was loose.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009 that requires Carbon Monoxide detectors to be installed in most properties that has a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper level.

7.9.2 – Smoke & CO Detectors
Smoke & CO Detectors 1
SMOKE DETECTOR OLD

Some of the smoke detectors appeared to be old and beyond their expected life. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

7.11.1 – Fireplaces Gas/LP
FIREPLACE NOT OPERATIONAL

The gas fireplace did not respond to available controls and was not operational. A qualified contractor should evaluate and repair or replace as necessary.

8 – Kitchen
8.2.1 – Doors
STRIKE NOT LATCHING
KITCHEN

The door would not latch when closed, and may need adjustment at the strike plate to latch properly. A qualified contractor should evaluate and repair or replace as necessary.

8.6.1 – Electrical Outlets
Electrical Outlets 1
NO GFCI PROTECTION
KITCHEN

No ground fault circuit interrupter (GFCI) protection was provided for kitchen electrical outlets. Although GFCI protection of kitchen circuits may not have been required at the time in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing kitchen electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary.

9 – Laundry
9.9.1 – Electrical Outlets
Electrical Outlets 2
GFCI PROTECTION NOT PRESENT
LAUNDRY AREA

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

10 – Bathroom 
10.6.1 – Windows
Windows 1
SEALANT DAMAGED AROUND FRAME
PRIMARY BATHROOM

Sealant was damage deteriorated around the window. Recommend a qualified contractor repair or replace as necessary.

10.12.1 – Plumbing Fixtures
LEAK – SHOWER CONTROL VALVE
PRIMARY BATHROOM

A control valve at the shower was leaking during operation at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary.

10.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT COLD
PRIMARY BATHROOM RIGHT

The water was not cold. Recommend a qualified contractor evaluate and repair or replace as necessary.

10.18.1 – Whirlpool/Jetted Bathtub
Whirlpool/Jetted Bathtub 1
NOT FUNCTIONING
PRIMARY BATHROOM

Inspection of the Whirlpool jetted bathtub is beyond the scope of the property inspection. The bathtub was filled and turned on using normal operating controls as a courtesy to the client. The Jetted tub did not turn on and appeared to be inoperable at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

11 – Bathroom 2
11.2.1 – Doors
Doors 1
MISSING – DOORSTOP
UPSTAIRS BATHROOM

The door had a damaged or missing doorstop.  A qualified contractor should evaluate and repair or replace as necessary.

11.12.1 – Plumbing Fixtures
LEAK – SHOWER CONTROL VALVE
UPSTAIRS BATHROOM

A control valve at the shower was leaking during operation at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary.

12- Bathroom 3 
12.12.1 – Plumbing Fixtures
LEAK – SINK CONTROL VALVE
1/2 BATHROOM

A control valve at the sink was leaking during operation at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary.

13 – Bathroom 4
13.5.1 – Floors
Floors 1
CARPET BY SHOWER, TOILET AREAS
BASEMENT BATHROOM

Carpeting was used as a floor covering material in the tub, shower, and/or toilet areas. The carpet is bound to get wet from steam/vapor from the shower, splashing, and water dripping off a body. Carpet tends to act as a sponge and soak up the moisture, which gives mildew and molds an opportunity to grow and spread. Recommend a qualified contractor evaluate and replace the floor covering materials as needed.

13.12.1 – Plumbing Fixtures
LEAK – SINK CONTROL VALVE
BASEMENT BATHROOM

A control valve at the sink was leaking during operation at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary.

15 – Electrical
15.2.1 – Distribution Panels
Distribution Panels 1
INADEQUATE WORKSPACE – PANEL

The distribution panel had inadequate clear space that is 3 feet deep, 30 inches wide, and 6′ 6″ in height in front of the equipment. A qualified contractor should evaluate and repair or replace as necessary.

15.2.2 – Distribution Panels
Distribution Panels 2
SCREWS MISSING – PANEL COVER

Screws / fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

16 – Water Heating Equipment 
16.1.1 – General Information
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

16.3.1 – Pipe Connections
Pipe Connections 1
CORRODED – PIPE FITTINGS
Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
16.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

17 – Heating 
17.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

17.1.2 – Heating System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

17.7.1 – Condensate
Condensate 1
SIGNS OF LEAKING

The condensation drain components for the HVAC system were leaking or showed signs of previous leaking. A qualified contractor should evaluate and repair or replace as necessary.

18 – Cooling
18.1.1 – Cooling System Information
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

18.1.2 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

18.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

18.7.1 – Evaporator Coils
Evaporator Coils 1
Evaporator Coils 2
SIGNS OF LEAKING, CORROSION

Signs of leaking, corrosion, or rusting were present at the visible refrigerant lines connected to the evaporative coil. Leaking from this location may possibly have a compounded effect on the components beneath it which typically includes the furnace heat exchanger. Delays or failure to correct this issue may cause extended damage. Recommend a qualified contractor evaluate and repair or replace as needed.

19 – Structural Basement
19.3.1 – Foundation Wall
Foundation Wall 1
Foundation Wall 2
MINOR CRACKS

There were minor to moderate cracks in the basement foundation wall. These cracks should be sealed to prevent moisture intrusion and monitored for further movement. Further analysis by a licensed structural engineer is recommended. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540

19.7.1 – Insulation
Insulation 1
Insulation 2
NO INSULATION

There is no insulation on the basement exterior walls or floor system. Heat loss can occur more on this property than one that is properly insulated. A qualified contractor should evaluate and install as necessary.

19.9.1 – Electrical in Basement
Electrical in Basement 1
JUNCTION BOX MISSING COVER PLATE

Splice/Junction box was missing a cover plate. A qualified contractor should evaluate and repair or replace as necessary.