2 – Roof
2.2.1 – Roof Covering
 Roof Covering 1
DAMAGED/DETERIORATED

The roof covering material was damaged/deteriorated in some areas.  A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.2.2 – Roof Covering
Roof Covering 2
Roof Covering 3
DEGRANULATED

Some of the shingles appeared to be de-granulated in areas. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.2.3 – Roof Covering
Roof Covering 4
Roof Covering 5
Roof Covering 6
EXPOSED NAILS
ONE OR MORE

The inspector observed exposed nails on the roof covering. This condition could allow moisture to penetrate the roof component. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

4 – Exterior
4.11.1 – Walkways
Walkways 1
IMPROPERLY SLOPED SURFACE

The walkway(s) have a negative slope and drains towards the home in areas. This condition is prone to water penetration into the home structure. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.11.2 – Walkways
Walkways 2
SIGNS OF REPAIRS

Signs of repairs were present in the walkway(s) in areas. Recommend asking current homeowner for more information, and if repairs appear to be of poor quality it is recommended to have a qualified contractor evaluate further for any additional repairs necessary.

4.18.1 – Exterior Vents
Exterior Vents 1
CLOGGED SCREEN
ROOF

A vent had a screen that was clogged with debris and could prevent proper air flow.

A fresh air vent to a gas burning appliance with clogged screen may affect the performance of the appliance.

A bathroom exhaust with a clogged screen may restrict air flow, resulting in excess condensation for the unit.

A qualified contractor should inspect and repair as necessary and according to current standards.

5 – Attached Garage
5.2.1 – Occupant Door
Occupant Door 1
TOP LOCK

Top lock of the door to the exterior does not lock. Recommend a qualified contractor for reevaluation or repair as necessary.

5.6.1 – Door Opener
EXCESSIVE VIBRATION
The garage door and operator motor moved or vibrated excessively when opening/closing. This may relate to a defect with the roller and track assembly, spring assembly, operator motor mount, or possibly the operator motor itself. Recommend a qualified contractor evaluate and repair or replace as needed.
5.6.2 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

6 – Interior, Doors, Windows
6.4.1 – Doors
Doors 1
LOOSE – HINGE
GUEST BEDROOM 2

The door had one or more loose hinges.  A qualified contractor should evaluate and repair or replace as necessary.

8 – Laundry
8.4.1 – Exhaust Fan
Exhaust Fan 1
NO VENT NO WINDOW

The laundry room did not have an exhaust fan or an openable window. A qualified contractor should evaluate, then repair or replace as advised.

9 – Bathroom
9.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

10 – Bathroom 2
10.15.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 2
WATER NOT HOT

The hot water in the shower did not get over 100 degrees whereas the nearby faucets did. This may indicate that either the mixing valve (safety feature to limit potential scalding) or control cartridge needs adjustment to achieve a hot shower. There may be a more significant issue, that only further evaluation can reveal.

Hot and cold supply was installed correctly and the property’s overall hot water temperature was within an acceptable range.

Recommend a qualified contractor evaluate and repair or replace as necessary.

12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too.

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

12.6.1 – Electrical Wiring
Electrical Wiring 1
SOLID ALUMINUM BRANCH-CIRCUIT WIRING

Solid conductor aluminum branch-circuit wiring was present. This is an electrical hazard. A qualified contractor should evaluate the electrical system and repair or replace as necessary.

Aluminum wire appears to be installed on branch electrical circuits in the subject premises. These single strand, branch circuit aluminum wires were used widely in houses during the mid 1960s and 1970s. According to the U.S. Consumer Product Safety Commission, problems due to expansion can cause overheating at connections between the wire and devices (switches and outlets) or at splices, which has resulted in fires. For further information on aluminum wiring contact the U.S. Consumer Product Safety Commission via the Internet at http://www.cpsc.gov.

For more details, visit InterNACHI’s Free Inspection Library.

13 – Water Heating Equipment

13.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH

The water temperature was higher than the acceptable range of 120-130 degrees. We recommend adjusting the water heater thermostat.

14 – Heating
14.7.1 – Condensate
Condensate 1
SECONDARY

The secondary drain line was capped or not routed to a drain. If the primary drain line becomes blocked, this condition could cause condensation to not drain properly and possibly damage the unit. The inspector recommends installing a secondary drain or installing an over flow protection device. A qualified contractor should evaluate then repair or replace as advised.

15 – Cooling
15.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16 – Structural Crawlspace
16.7.1 – Ventilation
Ventilation 1
OBSTRUCTED

A crawlspace vent was obstructed or covered at the time of inspection. This may prevent proper ventilation into the crawlspace. Recommend a qualified contractor evaluate and repair or replace as needed.