4 – Attached Garage
4.2.1 – Occupant Door
Occupant Door 1
NOT SELF CLOSING

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazard and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Floor
Floor 1
Floor 2
CRACKING – COMMON

The concrete floor in the garage was cracked. Due to expansive soils, minor cracks are to be expected in the slabs or control joints. Recommend a qualified contractor evaluate and repair or replace as needed.

4.6.1 – Door Opener
Door Opener 1
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

4.9.1 – Stairs & Railings
Stairs & Railings 1
STAINED
 5 – Interior, Doors, Windows
5.3.1 – Floors
Floors 1
Floors 2
CARPET LOOSE

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.1 – Windows
Windows 1
WONT STAY OPEN

A window sash would not stay up/open at the time of inspection. The window may have had damaged spring rails or springs that were damaged or weak. If this is an older counterweighted window, the counterweights may need to be adjusted. Recommend a qualified contractor evaluate and repair or replace it as necessary.

 6 – Kitchen
6.5.1 – Cabinets & Counters
Cabinets & Counters 1
DAMAGED – CABINET FLOOR

The cabinet floor was damaged. This may be from excessive leaking pipes, condensation, or even leaking cleaners stored in cabinet over the years.

A qualified contractor should evaluate and repair or replace as necessary.

6.5.2 – Cabinets & Counters
Cabinets & Counters 2
Cabinets & Counters 3
NOT CLOSING FLUSH

One or more cabinet door and/or drawer was not closing flush to the base cabinetry at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as needed.

6.12.1 – Food Waste Disposer
Food Waste Disposer 1
LEAKS

The food waste disposer was leaking at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Bathroom
8.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

8.14.1 – Tub, Shower Area
Tub, Shower Area 1
MISSING/DAMAGED GROUT

Tiles on the wall in the bath/shower area had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom 2
9.4.1 – Ceilings & Walls
Ceilings & Walls 1
NAIL POPS-CEILINGS

There were “nail pops” visible on the interior ceilings.  A qualified contractor should evaluate and repair or replace as necessary.

9.14.1 – Tub, Shower Area
Tub, Shower Area 1
Tub, Shower Area 2
CAULK – CORNERS AND FLOOR

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

 12 – Electrical
12.2.1 – Distribution Panels
Distribution Panels 1
SCREWS MISSING – PANEL COVER

Screws / fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

12.5.1 – Electrical Circuit Breakers
Electrical Circuit Breakers 1
POSSIBLE MOISTURE DAMAGE
 13 – Water Heating Equipment
13.12.1 – Operation & Response to Controls
Operation & Response to Controls 1
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

 14 – Heating
14.1.1 – Heating System Information
Heating System Information 1
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

14.7.1 – Condensate
Condensate1
SECONDARY

The secondary drain line was capped, missing or not routed to a drain. If the primary drain line becomes blocked, this condition could cause condensation to not drain properly and possibly damage the unit. The inspector recommends installing a secondary drain or installing an over flow protection device. A qualified contractor should evaluate then repair or replace as advised.

14.7.2 – Condensate
Condensate 2
MISSING TRAP

The condensation line was missing a trap. This condition allows conditioned air to escape through the condensation line. A qualified contractor should evaluate then repair or replace as advised.

 15 – Cooling
15.1.1 – Cooling System Information
Cooling System Information 1
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition is recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

15.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

15.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

15.3.2 – AC Compressor
AC Compressor 2
AC Compressor 3
COIL FINS DAMAGED

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

  15.3.3 – AC Compressor

AC Compressor 4
CLEAN/SERVICE

Due to the current conditions at the time of inspection, the air conditioner is recommended to be cleaned, evaluated, and serviced by a qualified contractor. Consult with your real estate agent for your available options prior to closing.

15.4.1 – AC Service Disconnect
AC Service Disconnect 1
BOLTED SHUT