4 – Attic, Insulation and Ventilation 2
4.1.1 – Attic Access
Attic Access 1
HATCH NOT INSULATED

The attic access hatch was not properly insulated. A qualified contractor should evaluate and repair or replace as necessary.

4.2.1 – Attic Structural Components
Attic Structural Components 1
ROOF DECKING SPLIT

The roof decking was split.  A qualified contractor should evaluate and repair or replace as necessary.

4.3.1 – Attic Moisture Intrusion
Attic Moisture Intrusion 1
RUSTY NAILS

Rusty nails often signal excess condensation build-up due to poor ventilation. Recommend a qualified contractor evaluate further to repair or replace as needed.

4.4.1 – Insulation in Attic
Insulation in Attic 1
COMPRESSED – INSULATION

The insulation had been walked on or had stored items compressing it, which reduces the R-value.

Recommend a qualified contractor evaluate and repair or replace as needed.

 5 – Exterior
5.2.1 – Driveways
Driveways 1
Driveways 2
CRACKING – MODERATE

The concrete driveway was moderately cracked. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

5.2.2 – Driveways
Driveways 3
SPALLING

The driveway surface was spalling in areas. This condition will continue to degrade if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

5.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
DAMAGED – SIDING
FRONT

The siding and/or trim was damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.10.1 – Window Wells
Window Wells 1
Window Wells 2
WINDOW WELLS MISSING COVERS

Window Well(s) lacked covers and may represent a danger to small children and may trap pests. A qualified contractor should evaluate and repair or replace as necessary.

5.11.1 – Walkways
Walkways 1
Walkways 2
CRACKING – SIGNIFICANT

There were signs of significant cracking on the walkway(s) in areas. Cracks that with a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. These cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

5.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
COULDN’T REMOVE GARDEN HOSE
BACK

The outside water faucet is connected to a garden hose. The hose could not be removed to inspect the faucet’s current operation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.16.1 – Gas Meter, Gas Shut-Off
Gas Meter, Gas Shut-Off 1
GAS METER TILTED

The gas meter is tilted as if the ground at the meter had settled.  A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.17.1 – Exterior Foundation Wall
Exterior Foundation Wall 1
CRACKS – AT CORNER(S)
FRONT LEFT

The exterior foundation wall had cracks at the corner. A qualified contractor should evaluate and repair or replace as necessary.  Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

5.17.2 – Exterior Foundation Wall
Exterior Foundation Wall 2
CRACK – VERTICAL
LEFT SIDE

The foundation had vertical cracks in areas. A qualified contractor should evaluate and repair as necessary before your inspection objection deadline.

5.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
EXTENSIONS NOT POSITIONED PROPERLY

One or more downspout extensions were not properly positioned. Extensions should be properly attached with a proper slope to guide run-off 5 feet away from the foundation structure.

Recommend a qualified contractor evaluate and repair or replace as necessary.

 6 – Attached Garage
6.2.1 – Occupant Door
Occupant Door 1
GAP AROUND DOOR
GARAGE

Daylight or blank space was visible between door and frame/jamb at an exterior entry door in the garage. Door may be missing weatherstripping or door is not installed properly. Recommend a qualified contractor evaluate and repair or replace as necessary.

6.2.2 – Occupant Door
Occupant Door 2
NOT FIRE RATED

The inspector was unable to verify that the door was fire rated . This may be considered a fire safety hazard. The door between the garage and the house should be a solid wood door at least 1-3/8 inches thick, a solid or honeycomb-core steel door at least 1-3/8 inches thick, or a 20-minute fire-rated door. This means that should a fire occur in garage, the occupant door does not afford protection until firemen arrive. A qualified contractor should evaluate and repair or replace as necessary.

6.2.3 – Occupant Door
Occupant Door3
Occupant Door 4
OPENS OVER STEP

The door swings over the top step of the stairway when opened.  This can lead to a fall and is considered a safety hazard.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.1 – Ceiling, Walls & Firewalls
Ceiling, Walls & Firewalls 1
DAMAGE – WALL

An interior wall in the garage was damaged.

Recommend a qualified contractor evaluate and repair or replace as needed.

6.3.2 – Ceiling, Walls & Firewalls
Ceiling, Walls & Firewalls 2
FIREWALL BREAK – ATTIC ACCESS

An attic access panel in the ceiling of the garage was not properly trimmed or sealed and is considered a break in the firewall between the garage and habitable areas.

Should the interior attic span across the entire structure, the attic access should be installed according to current fire rating standards. Alternatively, there may be a wall to separate the garage and the house or attic space. This wall must be covered with at least 1/2-inch thick (and preferably 5/8-inch thick Type X) gypsum board or equivalent applied to the garage side.

Recommend a qualified contractor evaluate and repair or replace as needed.

6.5.1 – Vehicle Door
Vehicle Door 1
NOT SEALED AT FLOOR

The garage door was missing weather stripping or did not evenly seal at the floor or sides of the door. A qualified contractor should evaluate and make adjustments, repair, or replace as necessary.

6.6.1 – Door Opener
Door Opener 1
MISSING – REVERSE SENSORS

The automatic reverse sensors are missing.

These are a safety feature to prevent injury, and should be installed no more than 6 inches away from the floor.

6.6.2 – Door Opener
NOT PRESENT – OPENER, BUTTON

A push-button opener on the wall was missing at the time of the inspection.  Recommend a qualified contractor evaluate further and repair or replace as needed.

6.7.1 – Electrical Outlets & Fixtures
Electrical Outlets & Fixtures 1
NO GFCI PROTECTION
GARAGE

The garage had one or more outlets without GFCI (or ground fault circuit interrupter) protection.

GFCI protection is required for all 15- and 20-amp receptacles, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage. A qualified contractor should evaluate and repair or replace as necessary.

 7 – Interior, Doors, Windows
7.2.1 – Ceilings & Walls
Ceilings & Walls 1
BULGE
BASEMENT BEDROOM

The wall was bowed or bulges in areas.  A qualified contractor should evaluate and repair or replace as necessary.

7.2.2 – Ceilings & Walls
Ceilings & Walls 2
MISSING – BASEBOARD TRIM
STAIRWAY

Baseboard trim was missing in areas of the interior walls at the time of inspection. A qualified contractor should evaluate and repair or replace as needed.

7.3.1 – Floors
Floors 1
CARPET DAMAGED
STAIRWAY

The carpet was damaged in areas. A qualified contractor should evaluate and repair or replace as necessary.

7.3.2 – Floors

Floors 2

Floors 3

SLOPED
BASEMENT

Floor has a dip or is sloped in areas.

Recommend a qualified contractor evaluate and repair or replace as needed.

7.4.1 – Doors
Doors 1
OFF TRACK
BASEMENT MECHANICAL ROOM

The sliding/folding door would fall off the track when operated.  A qualified contractor should evaluate and repair or replace as necessary.

7.7.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
FAN NOT WORKING
PRIMARY BEDROOM

The ceiling fan did not work. A qualified contractor should evaluate and repair or replace as necessary.

7.8.1 – Stairways & Railings
Stairways & Railings 1
NO RETURN AT ENDS

At the interior stairs, the handrail had a railing end that did not return to the wall or post.  A fall could occur if something (purse, backpack etc.) caught the end of the railing when descending. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

7.10.1 – Installed Heat Source
Installed Heat Source 1
Installed Heat Source 2
NO HEAT SOURCE
BASEMENT LIVING ROOM

There was no heat source installed in the basement living area.  A qualified contractor should evaluate and repair or replace as necessary.

 9 – Laundry
9.9.1 – Electrical Outlets
Electrical Outlets 1
GFCI PROTECTION NOT PRESENT
LAUNDRY AREA

An outlet did not provide Ground Fault Circuit Interrupter (GFCI) protection. Although GFCI protection of circuits may not have been required at the time in which this home was built, safe building practices have improved with the passage of time and building standards have changed to reflect current understanding. The inspector recommends updating the existing electrical circuits to include GFCI protection. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom
10.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE STAINING-CEILINGS
UPSTAIRS BATHROOM

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

10.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.1 – Plumbing Fixtures
Plumbing Fixtures 1
CHIPPED – TUB
UPSTAIRS BATHROOM

The bathtub finish was chipped or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

10.12.2 – Plumbing Fixtures
Plumbing Fixtures 2
LEAK – SHOWER HEAD
UPSTAIRS BATHROOM

There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – CORNERS AND FLOOR

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

 11 – Bathroom 2
11.2.1 – Doors
Doors 1
OFF TRACK
BASEMENT BATHROOM

The sliding/folding door would fall off the track when operated.  A qualified contractor should evaluate and repair or replace as necessary.

11.4.1 – Ceilings & Walls
Ceilings & Walls 1
TAPE PULLING
BASEMENT BATHROOM

The drywall showed pulling or wrinkling of the drywall tape at the corner which may reflect structural movement in that area.  A qualified contractor should evaluate and repair or replace as necessary.

11.7.1 – Electrical Outlets
Electrical Outlets 1
NO GFCI PROTECTION
BASEMENT BATHROOM

No ground fault circuit interrupter (GFCI) protection was provided for the bathroom electrical outlets. Although GFCI protection of bathroom circuits may not have been required at the time of in which this property was built, as general knowledge of safe building practices has improved with the passage of time building standards have changed to reflect current understanding. The inspector recommends updating the existing bathroom electrical circuits to provide GFCI protection. This can be achieved by:

1. Replacing the current standard outlets with GFCI outlets.

2.  Replacing the first circuit outlet located closest to the main electrical service panel with the GFCI outlet

3.  Replacing the breaker currently protecting the electrical circuit that contains these outlets with the GFCI breaker.

A qualified contractor should evaluate and repair or replace as necessary.

11.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
NOT WORKING – SINK STOPPER

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

11.13.1 – Toilets
Toilets 1
LOOSE AT THE FLOOR
BASEMENT BATHROOM

The toilet was loose at the floor. This condition typically is caused by loose bolts or nuts and/or missing floor seals. Loose toilet can result in leaks, water damage, and mold, as well as damage to the toilet, water supply lines, bolts, and drainage pipes. A qualified contractor should evaluate and repair or replace as necessary.

11.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – SPOUT/LEVER

The tub spout and or control lever cover plate was missing silicone caulking.  A qualified contractor should evaluate and repair or replace as necessary.

11.14.2 – Tub, Shower Area
Tub, Shower Area 2
DETERIORATED – CAULKING/GROUT

Caulking in the shower/tub area was deteriorated at the time of inspection. Recommend a qualified contractor evaluate and repair or replace as necessary.

 12 – Plumbing
12.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 13 – Electrical
13.1.1 – Electric Meter & Base
Electric Meter & Base 1
METER BASE NOT SECURE

The electric meter base was loose at time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

13.1.2 – Electric Meter & Base
Electric Meter & Base 2
OPEN KNOCK OUT

There is an open knock out in the bottom of the electric meter. A qualified electrician or public utility service should investigate and repair or replace as necessary.

13.6.1 – Electrical Wiring
Electrical Wiring 1
Electrical Wiring 2
Electrical Wiring 3
SOLID ALUMINUM BRANCH-CIRCUIT WIRING

Solid conductor aluminum branch-circuit wiring was present. This is an electrical hazard. A qualified contractor should evaluate the electrical system and repair or replace as necessary.

Aluminum wire appears to be installed on branch electrical circuits in the subject premises. These single strand, branch circuit aluminum wires were used widely in houses during the mid 1960s and 1970s. According to the U.S. Consumer Product Safety Commission, problems due to expansion can cause overheating at connections between the wire and devices (switches and outlets) or at splices, which has resulted in fires. For further information on aluminum wiring contact the U.S. Consumer Product Safety Commission via the Internet at http://www.cpsc.gov.

For more details, visit InterNACHI’s Free Inspection Library.

13.8.1 – Sub-Panel
Sub-Panel 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power too.

Recommend a qualified contractor verify the breakers and accuracy of any existing labeling as necessary.

13.8.2 – Sub-Panel
Sub-Panel 2
MISSING – MANUFACTURERS LABEL

The manufacturer’s label was missing, partial, or illegible at the  electrical service panel. The manufacturer’s label typically provides information describing the main panel such as the name of the panel manufacturer, the panel model number, the panel amperage rating, limitations related to the environment in which the panel was designed to be installed and grounding/bonding information for that particular model. The Inspector was unable to confirm the existence of proper conditions when confirmation would require information taken from this missing label.

 14 – Water Heating Equipment
14.8.1 – Temperature & Pressure Relief Valve
Temperature & Pressure Relief Valve 1
MISSING – PIPE

The temperature pressure relief valve was missing a pipe at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

14.13.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace as necessary.

 15 – Heating
15.10.1 – Blower
Blower 1
BLOWER WHEEL DIRTY

The blower motor and/or wheel appeared to be dirty at the time of inspection. Blower fan motors and fan wheels are subjected to constant dirt, dust, and lint and can become overly dirty when not cleaned on a regular basis and even faster if the air filters are not changed regularly.

A qualified contractor should evaluate, clean, and service as necessary, and certify the unit is in good working order.

15.12.1 – Heating System Ignition & Operation
SHORT CYCLING

The furnace was short-cycling (repeated start-up and shut-down within minutes of each other) at the time of the inspection. Most systems should run about 2-3 cycles per hour. A qualified contractor should evaluate and repair or replace as necessary.

 16 – Cooling
16.3.1 – AC Compressor
AC Compressor 1
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

16.6.1 – Cooling System Operation
Cooling System Operation 1
Cooling System Operation 2
Cooling System Operation 3
DID NOT PRODUCE COOLED AIR

The cooling system turned on but did not operate as expected by producing adequate conditioned cooled air. An ambient air test was performed to determine if the difference in temperatures of the supply and return air was between 14 degrees and 22 degrees. A qualified contractor should evaluate and repair/replace as necessary.

 17 – Structural Basement
17.2.1 – Basement Floor
Basement Floor 1
Basement Floor 2
CRACKED – COMMON

The concrete floor in the basement was cracked in areas. These cracks appear to be common cracks indicating regular settlement or heaving, but not necessarily structural problems. Recommend a qualified contractor to evaluate to make further recommendations and repair as necessary.

Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

17.4.1 – Basement Interior Wall Structure
Basement Interior Wall Structure 1
Basement Interior Wall Structure 2
BASEMENT WALLS NOT FLOATING

Basement walls were not constructed using a method which will allow for soil movement. This method is usually termed “floating” the walls and involves leaving a gap at the bottom of the wall so that vertical movement (heaving) of the concrete slab basement floor will not be transmitted to the rest of the property structure. Colorado has areas with expansive soils. Expansive soils are soils which increase to many times their original volume in response to increases in soil moisture content, creating forces which can easily damage property structural components such as foundations, floor slabs, flat work and interior and exterior wall coverings. Consider consulting with a qualified contractor before the expiration of your Inspection Objection Deadline to discuss options and costs for correction an/ or stabilization.

17.5.1 – Moisture Intrusion
Moisture Intrusion 1
MOISTURE INTRUSION

The visible areas of the basement showed signs of possible previous moisture intrusion and/or deterioration. A qualified contractor should evaluate and repair or replace as necessary.

17.8.1 – Vapor Barriers
VAPOR BARRIER NOT INSTALLED

A vapor barrier was not installed in the basement at the time of the inspection. A qualified contractor should evaluate and install as necessary.