2 – Exterior
2.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
CRACKING – MINOR

Siding showed cracking and or damage in one or more places. Recommend monitoring, and if the problem exacerbates, a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2
DAMAGED – SIDING

The siding and/or trim was damaged in areas of the exterior.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

2.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 3
DETERIORATION

The exterior wall covering is beginning to deteriorate or has deteriorated.

Recommend a qualified contractor should evaluate and repair or replace as needed.

2.12.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
Vegetation, Grading & Drainage 2
ERODED GRADE

Grade has eroded or was poorly back-filled near the foundation wall, patio, or stairway. This may allow moisture to pool near the structure, and this may allow significant cracking if not corrected.

Recommend a qualified contractor evaluate and repair or replace as necessary.

2.15.1 – Sump Pump Discharge Pipe
Sump Pump Discharge Pipe 1
DISCHARGE TOO CLOSE

The sump pump discharge pipe did not terminate far enough away from the foundation. Erosion can continue or become worse if not corrected possibly leading to water intrusion. This condition may cause problems by introducing excessive amounts of moisture to the soil near the foundation. A qualified contractor should evaluate and install a proper extension, to properly route drainage away from the foundation, usually at least 6 feet.

 4 – Interior, Doors, Windows
4.2.1 – Ceilings & Walls
Ceilings & Walls 1
CRACKING AROUND WINDOW

There was cracking around some windows on the interior (where the window meets the wall).  A qualified contractor should evaluate and repair or replace as necessary.

4.2.2 – Ceilings & Walls
Ceilings & Walls 2
DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

4.2.3 – Ceilings & Walls
Ceilings & Walls 3
SIGNS OF REPAIR-WALLS

The interior walls have signs of repairs. Recommend asking the current homeowner for more information. Recommend further evaluation from a qualified contractor should the repairs be excessive or of visibly poor quality.

4.3.1 – Floors
Floors 1
WEAR AND TEAR

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

4.5.1 – Windows
Windows 1
SCREENS DAMAGED/MISSING

Some windows had damaged or missing screens.  A qualified contractor should evaluate and repair or replace as necessary.

4.8.1 – Stairways & Railings
Stairways & Railings 1
LOOSE – HANDRAIL

At the interior stairs, the handrail was loose.  A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Fireplaces Gas/LP
Fireplaces Gas/LP 1
FIREPLACE – DIRTY

Excessive lint, dust and/or debris was built up in the  pilot ignition compartment. Recommend further evaluation and proper cleaning by a qualified professional.

 5 – Kitchen
5.5.1 – Cabinets & Counters
Cabinets & Counters 1
CHIPPED – TILE COUNTER TOP

Tile in the kitchen counter top was chipped or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

5.5.2 – Cabinets & Counters
Cabinets & Counters 3
POSSIBLE MOLD

Evidence of a possible mold like substance was observed.  We did not inspect, test or determine if this growth is or is not a health hazard. The underlying cause is moisture. It is recommended to consult a mold inspector or mold remediation specialist to determine if further action is needed. Further analysis by a mold remediation specialist is recommended. Axium recommends our premier partner – Mold Removal Express. They can be contacted at 720-464-1555 or online at www.axiuminspections.com/mold-removal-express.

5.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
Drain Waste and Vent System 2
SINK LOOSE
5.13.1 – Dishwasher
Dishwasher 1
Dishwasher 2
LEAKED

The dishwasher leaked while going through a normal cycle.  A qualified contractor should evaluate and repair or replace as necessary.

 6 – Laundry
6.4.1 – Exhaust Fan
FAN NEEDED

There was no ventilation (exhaust fan or openable window) In the laundry area. Normally an exhaust fan or an openable window is needed for proper ventilation.  A qualified contractor should evaluate and repair or replace as necessary.

 7 – Bathroom
7.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACK SPLASH

The counter top needs caulking with silicone along the back splash.  A qualified contractor should evaluate and repair or replace as necessary.

7.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
CLOGGED/SLOW – SINK DRAIN

The sink drain line was clogged or drains slowly. A qualified contractor should evaluate and repair or replace as necessary.

7.13.1 – Toilets
Toilets 1
SEAT LOOSE/DAMAGED

The toilet seat was loose or damaged.  A qualified contractor should evaluate and repair or replace as necessary.

 8 – Bathroom 2
8.6.1 – Windows
Windows 1
CRANK HANDLE DAMAGED/NOT WORKING

The window had a crank handle that was damaged or not working properly.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Plumbing
10.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure  measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances is likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 11 – Electrical
11.2.1 – Distribution Panels
Distribution Panels 1
INADEQUATE WORKSPACE – PANEL

The distribution panel had inadequate clear space that is 3 feet deep, 30 inches wide, and 6′ 6″ in height in front of the equipment. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Water Heating Equipment
12.1.1 – General Information
General Information 1
OLDER THAN 10 YEARS

The water heater was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of the tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

 13 – Heating
13.7.1 – Condensate
Condensate 1
SECONDARY

The secondary drain line was capped, missing or not routed to a drain. If the primary drain line becomes blocked, this condition could cause condensation to not drain properly and possibly damage the unit. The inspector recommends installing a secondary drain or installing an over flow protection device. A qualified contractor should evaluate then repair or replace as advised.

13.9.1 – Air Filter
Air Filter 1
DIRTY

The HVAC system air filter was dirty. Clogged filters can restrict airflow and increase internal temperatures. A clean air filter will help increase the efficiency and prolong the life expectancy of the system. Due to the damage that can be caused by dirty or clogged coils, recommend replacing the filter, as well as cleaning, servicing, and evaluating the HVAC system by a qualified HVAC professional and repair or replace as necessary.

 14 – Cooling
14.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

14.3.1 – AC Compressor
AC Compressor 1
INADEQUATE CLEARANCE – RESTRICTED AIR FLOW

The air conditioner unit did not have proper clearance and the air flow was likely restricted. This may result in inefficient operation.

14.3.2 – AC Compressor
AC Compressor 2
CLEAN/SERVICE

Due to the current conditions at the time of inspection, the air conditioner is recommended to be cleaned, evaluated, and serviced by a qualified contractor. Consult with your real estate agent for your available options prior to closing.