2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
SIGNS OF REPAIR
1ST FLOOR FRONT

The inspector observed signs of repair at the time of inspection. A qualified contractor should evaluate, then repair or replace as advised prior to the inspection objection deadline.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
RUBBER BOOT DAMAGED

One or more plumbing vents had a rubber boot flange that was damaged. This condition could allow moisture to penetrate the roof component.  A qualified contractor should evaluate,  then repair or replace as advised prior to the inspection objection deadline.

 3 – Attic, Insulation, and Ventilation
3.1.1 – Attic Access

Attic Access 1

DAMAGED HATCH

The attic access hatch was damaged. A qualified contractor should evaluate and repair or replace as necessary.

3.4.1 – Insulation in Attic
Insulation in Attic 1
NOT UNIFORM

The insulation is not uniform: thicker in areas, thinner in areas, or possibly missing in some areas.

Recommend a qualified contractor to evaluate and repair or replace as needed.

3.4.2 – Insulation in Attic
Insulation in Attic 2
TOO THIN

The insulation is thinner than current thermal resistance (R-value) standards.

Recommend a qualified contractor to evaluate and repair or replace as needed.

 4 – Exterior
4.2.1 – Driveways
Driveways 1
HEAVING AND/OR SETTLING

The driveway showed signs of heaving and/or settling in areas. Heaving is often caused by soil that has expanded in volume due to increased moisture content, or by wet soil which has expanded as it became frozen. Settlement is when the soil below a concrete slab is loose, or it can no longer support the weight causing it to sink or crack. This condition could potentially cause a trip hazard.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.2.2 – Driveways
Driveways 2
PITTED

The driveway surface was pitted in areas. A qualified contractor should evaluate and repair or replace as necessary.

4.3.1 – Garage Door Exterior
Garage Door Exterior 1
DAMAGED – WEATHER STRIPPING

The exterior of the garage door has damaged weather stripping. A qualified contractor should inspect and repair as necessary and according to current standards.

4.3.2 – Garage Door Exterior
Garage Door Exterior 2
Garage Door Exterior 2
PEELING PAINT

The exterior of the garage door has peeling paint in some areas. Caulking and painting is needed to seal the door from moisture intrusion. A qualified contractor should inspect and repair as necessary and according to current standards.

4.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
PENETRATIONS

There were penetrations in areas of the siding at the time of inspection. Recommend applying athe ppropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.

4.4.2 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 2

Wall-Covering, Flashing & Trim 3

Wall-Covering, Flashing & Trim 4
PEELING PAINT

Peeling paint was present in areas.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.4.3 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 5
Wall-Covering, Flashing & Trim 6
SEAL GAPS AT INTERSECTIONS
MULTIPLE AREAS

Gaps at intersections of the siding, trim, and door and window openings, as well as any other holes in the siding, should be sealed with an appropriate sealant to prevent water penetration into the wall system. A qualified contractor should evaluate and repair or replace as necessary.

4.4.4 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 7
Wall-Covering, Flashing & Trim 8
SWOLLEN – MOISTURE INTRUSION

The siding/trim had a swollen appearance due to moisture intrusion.

Recommend a qualified contractor should evaluate and repair or replace as needed.

4.5.1 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 1
GAPS AT INTERSECTIONS

The eaves had gaps at the edges between soffit panels or roof sheathing which allows insects to enter the attic.

Recommend a qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.5.2 – Eaves, Soffits & Fascia
Eaves, Soffits & Fascia 2
MOISTURE DAMAGE

Components of the eaves, facia, and/or soffit were warped, swollen, or had peeling paint which are signs of water damage. The materials will eventually begin to rot if left untreated or cause has not been corrected.

A qualified contractor should evaluate and repair or replace as necessary.

4.6.1 – Exterior Doors

Exterior Doors 1

DAMAGE – SCREEN DOOR

The screen door was damaged or deteriorated at the time of inspection.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.6.2 – Exterior Doors

Exterior Doors 2

BROKEN SEALS
4.8.1 – Windows
Windows 1
MISSING/DAMAGED – PAINT

A window frame, still, shutter, and/or trim had missing or damaged paint. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.8.2 – Windows
Windows 2
MISSING TOP FLASHING
ALL

The top window flashing was missing around the subject property. Recommend a qualified contractor to evaluate and repair or replace as needed.

4.10.1 – Walkways

Windows 1

CRACK AT STEP(S)

Cracking or separation was present at the concrete step(s) in areas. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.10.2 – Walkways

Windows 2

CRACKING – MINOR

Minor cracking was visible on the walkway(s) in areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

4.10.3 – Walkways

Windows 3

SPALLING

The walkway(s) had surface spalling in areas. This condition will continue to degrade if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

4.11.1 – Vegetation, Grading & Drainage
Vegetation, Grading & Drainage 1
DENSE VEGETATION

Dense vegetation was present around the house in areas.  This condition limited and restricted my visual inspection.  Dense vegetation and landscaping up against or near the house foundation and exterior walls may be prone to water penetration and insect infestation. Trimming, pruning ,and some landscaping are recommended by a qualified contractor

4.16.1 – Exterior Foundation Wall

Exterior Foundation Wall 1

CRACK – SETTLEMENT

The exterior foundation wall had settlement crack(s.) A qualified contractor should evaluate and repair or replace as necessary. Axium recommends our premier partner – Level Engineering. They can be contacted at 720-706-8540 or online at www.axiuminspections.com/structural-engineer.

4.18.1 – Decks & Balconies
Decks & Balconies 1
BOWED – STRUCTURE

A support post or floor joist was bowed at the deck. A qualified contractor should evaluate and repair or replace as necessary.

4.18.2 – Decks & Balconies
Decks & Balconies 2
CONTACT WITH GROUND

A wood support post or wood portion of the deck was in direct contact with the ground/dirt. The wood should be pressure treated and ideally be: placed in a metal bracket and/or cement casing, and have clearance from the ground level. Wood in direct contact with dirt will wick up ground moisture and deteriorate at an accelerated rate if routine maintenance is not kept.

Recommend a qualified contractor to evaluate and repair or replace as needed.

4.18.3 – Decks & Balconies
Decks & Balconies 3
DAMAGE AT STEP

A step was damaged at the deck. This condition may be a safety hazard.

Correction and further evaluation are recommended.

4.18.4 – Decks & Balconies
Decks & Balconies 4
CRACKED, SPLIT WOOD – DECK

Cracked or split boards were present on the deck.  This condition is a structural defect and potential safety hazard.

A qualified contractor should evaluate and repair or replace as necessary.

4.18.5 – Decks & Balconies
Decks & Balconies 5
IMPROPER FOOTING – SUPPORT POST

A support post was not properly rested on a concrete footer or missing metal connection hardware. This may put the wood in direct contact with the moisture on the ground and accelerate any potential deterioration.

A qualified contractor should evaluate and repair or replace as necessary.

4.20.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
EXTENSIONS TOO SHORT

One or more downspout extensions were too short. Recommend installing 6-8ft long (or greater as needed) extensions to divert rainwater runoff away from the property.

 5 – Attached Garage
5.5.1 – Vehicle Door
Vehicle Door 1
WEAK SPRINGS

The garage door was hard to lift or the spring(s) did not support the weight of the door when tested.

Recommend a qualified contractor to evaluate and repair or replace as necessary.

5.6.1 – Door Opener
Door Opener 1
MISSING – LIGHT COVER

The garage door operator unit was missing light bulb covers. Recommend a qualified contractor eto valuate and repair or replace as needed.

5.6.2 – Door Opener
Door Opener 2
REVERSE SENSORS TOO HIGH

The photo-electric reverse sensors are installed too high from the garage floor surface.

The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

 6 – Interior, Doors, Windows
6.3.1 – Floors

Floors 1

Floors 2

CARPET LOOSE

The carpet was loose or baggy and may need to be restretched.  A qualified contractor should evaluate and repair or replace as necessary.

6.3.2 – Floors
Floors 3
WEAR AND TEAR
THROUGHOUT PROPERTY

The floors showed signs of minor damage and wear, particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

6.6.1 – Electrical Outlets

Electrical Outlets 1

OUTLET HOT AND NEUTRAL REVERSED

One or more electrical outlet(s) were wired incorrectly with the hot and neutral wires being reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created as there is still electricity running through the hot wire when the switch is off. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

6.7.1 – Electrical Fixtures & Switches
FLICKERING LIGHT

The light fixture flickered possibly indicating a loose connection at the switch or fixture.  A qualified contractor should evaluate and repair or replace as necessary.

6.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
1ST FLOOR KITCHEN $ 2ND FLOOR

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used for sleeping purposes. The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that have a fuel-burning heater or appliance, a fireplace, or an attached garage.

There are no carbon monoxide detectors on the lower or upper levels.

6.9.2 – Smoke & CO Detectors

Smoke & CO Detectors 1

SMOKE DETECTOR NOT WORKING

The smoke detector did not work when tested. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

6.9.3 – Smoke & CO Detectors
Smoke & CO Detectors 2
SMOKE DETECTOR MISSING
1ST FLOOR KITCHEN

The smoke detector was missing. A qualified person should replace them as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

6.9.4 – Smoke & CO Detectors
Smoke & CO Detectors 3

Smoke & CO Detectors 4

SMOKE DETECTOR OLD

Some of the smoke detectors appeared to be old and beyond their expected life. A qualified person should repair or replace as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

 7 – Kitchen
7.3.1 – Ceilings & Walls

Ceilings & Walls 1

DAMAGED – WALLS

The walls showed signs of minor damage and wear.  A qualified contractor should evaluate and repair or replace as necessary.

7.3.2 – Ceilings & Walls
Ceilings & Walls 2
TAPE AND BED
KITCHEN

The drywall in some areas revealed the tape and nail bed. A qualified contractor should evaluate and repair or replace as necessary.

7.5.1 – Cabinets & Counters
Ceilings & Walls 1
WORN FINISH

Counters or cabinetry had a finish that was worn or peeling. Recommend a qualified contractor eto valuate and repair or replace as needed.

7.7.1 – Windows
Windows 1
BROKEN SEALS
KITCHEN

The window appeared to have a broken seal that has been compromised.  Condensation and/or cloudiness between the two panes of glass were observed.  This will have a negative impact on energy efficiency.  Also, because there is moisture between the panes with no ventilation, mold can eventually develop.  A qualified contractor should evaluate and repair or replace as necessary.

7.7.2 – Windows
Windows 2
STUCK SHUT
KITCHEN

The window had a sash that was unable to be opened without excessive force, possibly from being painted or nailed shut.  A qualified contractor should evaluate and repair or replace as necessary.

7.9.1 – Faucets Fixtures
Faucets Fixtures 1
HOT AND COLD REVERSED
KITCHEN

Hot and cold controls appeared to be reversed at the time of inspection. Recommend a qualified contractor eto valuate and repair or replace supply lines as needed.

 8 – Laundry
8.8.1 – Floors
Floors 1
WEAR AND TEAR

The floors showed signs of minor damage and wear – particularly in high-traffic areas.  A qualified contractor should evaluate and repair or replace as necessary.

 9 – Bathroom
9.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE DAMAGE-WALLS

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

9.5.1 – Floors
Floors 1
Floors 2
FLOOR NOT SEALED AT EDGE
PRIMARY BATHROOM

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

9.8.1 – Electrical Fixtures & Switches
Electrical Fixtures & Switches 1
NOT WORKING – BULB
PRIMARY BATHROOM

One or more bulbs were not working in the bathroom at the time of inspection.

Recommend a qualified contractor to evaluate and repair or replace as needed.

9.9.1 – Cabinets & Counters
Cabinets & Counters 1
WORN FINISH

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor to evaluate and repair or replace as needed.

9.14.1 – Tub, Shower Area
Tub, Shower Area 1
CAULK – CORNERS AND FLOOR

The tub/shower area had deteriorated or missing sealant (caulking or grout) at the corners and/or floor. Sealant is needed at wall corners inside the shower, corners from tub to wall, and along the floor perimeter.  A qualified contractor should evaluate and repair or replace as necessary.

 10 – Bathroom 2
10.4.1 – Ceilings & Walls
Ceilings & Walls 1
Ceilings & Walls 2
MOISTURE DAMAGE-WALLS
2ND FLOOR BATHROOM

The interior walls showed evidence that moisture was entering from behind possibly including damage and deterioration.  A qualified contractor should evaluate and repair or replace as necessary.

10.5.1 – Floors
Floors 1
FLOOR NOT SEALED AT EDGE
2ND FLOOR BATHROOM

The floor covering was not sealed at the edges and may allow moisture intrusion.  A qualified contractor should evaluate and repair or replace as necessary.

10.9.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH

The countertop needs caulking with silicone along the backsplash.  A qualified contractor should evaluate and repair or replace as necessary.

10.9.2 – Cabinets & Counters
Cabinets & Counters 2
WORN FINISH

Wood cabinetry had a finish that was worn or peeling. Recommend a qualified contractor eto valuate and repair or replace as needed.

10.14.1 – Tub, Shower Area
Tub, Shower Area 1
SEALANT – MULTIPLE AREAS

Some caulking and/or grout in the tub & shower area was missing, loose, old, or poorly done.  Recommend a qualified contractor evaluate and re-seal as needed.

 11 – Bathroom 3
11.5.1 – Floors
Floors 1
MISSING TRANSITION PIECE
1ST FLOOR BATHROOM

A transition piece was missing between two sections of flooring.  A qualified contractor should evaluate and repair or replace as necessary.

 13 – Plumbing
13.4.1 – Water Pressure
Water Pressure 1
HIGH WATER PRESSURE

The property water supply pressure is measured at the exterior faucet or laundry appliance hose bib. Property water supply pressure exceeded the 80 pounds per square inch (PSI) limit considered the maximum allowable by generally accepted current standards. Excessively high water pressure can stress connections in the plumbing system and appliances are likely to cause leaks.

A qualified contractor should install a pressure regulator or evaluate and repair or replace one as necessary.

 14 – Water Heating Equipment
14.9.1 – Exterior Condition/Leakage
Exterior Condition/Leakage 1
Exterior Condition/Leakage 2
NOT SUPPORTED/LEVEL

The water heating equipment was not properly supported/level. A qualified contractor should evaluate and repair or replace as necessary.

14.12.1 – Operation & Response to Controls
Operation & Response to Controls 1
FLAMES

Flames were not entirely burning a blue color. Orange and yellow flames may be an indicator that the fuel-air mixture is not right and gas may not be burning as efficiently as possible. Recommend a qualified contractor evaluate to adjust, repair, or replace fuel-burning components as necessary.

14.13.1 – Water Temperature
Water Temperature 1
Water Temperature 2
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace it as necessary.

 15 – Cooling
15.1.1 – Cooling System Information
Cooling System Information 1
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the cooling system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimated Life Expectancy Chart for Homes

15.1.2 – Cooling System Information
SERVICING RECOMMENDED

Based on the age of the cooling system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

15.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
DAMAGED INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

15.2.2 – AC Refrigerant Lines
AC Refrigerant Lines 2
GAP AROUND LINE AT WALL

The air-conditioner refrigerant suction line (large, insulated) exterior wall penetration should be sealed to prevent moisture and insect intrusion. A qualified contractor should evaluate and repair/replace as necessary.

15.3.1 – AC Compressor
AC Compressor 1
COIL FINS DAMAGED

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 

15.3.2 – AC Compressor
CLEAN/SERVICE

Due to the current conditions at the time of inspection, the air conditioner is recommended to be cleaned, evaluated, and serviced by a qualified contractor. Consult with your real estate agent for your available options prior to closing.

15.3.3 – AC Compressor
AC Compressor 2
RUSTED COMPONENTS

Surface and/or interior components of the AC condenser showed rust in areas. Recommend a qualified contractor to evaluate, service, and repair or replace as necessary.

 16 – Heating
16.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

16.1.2 – Heating System Information
Heating System Information 1
BEYOND TYPICAL LIFE EXPECTANCY

Due to the year of manufacture, the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate to clean, service/repair/replace as necessary, and certify the unit if possible.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

16.8.1 – Ductwork
Ductwork 1
Ductwork 2
DUCTS NOT SEALED

Air supply ducts were not sealed. Ideally, all ducts are sealed with mastic in order to be more energy-efficient. A qualified contractor should evaluate and repair as necessary.

16.12.1 – Heating System Ignition & Operation
Heating System Ignition & Operation 1
DIRTY

The heating system did fire and appeared to be in a serviceable condition at the time of the inspection. However, the interior of the cabinet was dirty. Cleaning, servicing, and/or certification of the HVAC system by a qualified contractor is recommended and repaired or replaced as necessary.

 18 – Structural Crawlspace
18.6.1 – Insulation
Insulation 1
PAPER FACING THE WRONG WAY

Insulation installed in the crawlspace had paper or foil backing facing the wrong direction. Thermal insulation should always be installed with paper or foil backing toward the source of heat. Reversal (backing on the cold side) may result in problems from the formation of excessive condensation. Excessive condensation may cause damage to property materials from decay or result in the development of microbial growth which can cause health problems in some people. A qualified contractor should evaluate and repair or replace as necessary.