2 – Roof
2.2.1 – Roof Covering
Roof Covering 1
Roof Covering 2
LEAKING
ROOF

The roof was actively leaking during the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

2.3.1 – Flashing
Flashing 1
WALL FLASHING IMPROPERLY SEALED
ROOF

Wall flashing appears to be improperly sealed in areas. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.

2.5.1 – Plumbing Vent Pipes
Plumbing Vent Pipes 1
PLUMBING VENT DAMAGED
ROOF

A plumbing vent was cracked/damaged in areas. A qualified contractor should evaluate and repair or replace as necessary.

 3 – Exterior
3.2.1 – Walkways & Driveways
Walkways & Driveways 1
MODERATE CRACKING – PARKING LOT
PARKING LOT

There were signs of moderate cracking in the parking lot areas. A qualified contractor should evaluate and repair or replace as necessary.

 

3.2.2 – Walkways & Driveways
Walkways & Driveways 2
MINOR CRACKING – WALKWAYS
FRONT OF THE UNIT

Minor cracking/signs of repair were visible at the walkway at the front of the uit. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary.

3.4.1 – Wall-Covering, Flashing & Trim
Wall-Covering, Flashing & Trim 1
PENETRATIONS
REAR OF THE UNIT

There were penetrations in areas of the siding at the time of inspection. Recommend applying the appropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.

 4 – Interior, Doors, Windows
4.2.1 – Ceilings & Walls
Ceilings & Walls 1
Ceilings & Walls 2
MOISTURE DAMAGE-CEILINGS
INTERIOR

The ceilings showed evidence that moisture was entering from behind including damage and deterioration at the time of inspection.  A qualified contractor should evaluate and repair or replace as necessary.

4.2.2 – Ceilings & Walls
Ceilings & Walls 3
Ceilings & Walls 4
Ceilings & Walls 5
MOISTURE STAINING-CEILINGS
INTERIOR

The ceiling tiles showed some moderate staining indicating moisture intrusion did or does still exist in multiple areas throughout the unit.  A qualified contractor should evaluate and repair or replace as necessary.

4.2.3 – Ceilings & Walls
Ceilings & Walls 6
MISSING – BASEBOARD TRIM
INTERIOR

Baseboard trim was missing in areas of the interior walls at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

4.2.4 – Ceilings & Walls
Ceilings & Walls 7
CRACKED MIRROR
INTERIOR

The mirror was cracked/damaged in areas in the interior. A qualified contractor should evaluate and repair or replace as necessary.

4.3.1 – Floors
Floors 1
Floors 2
CARPET STAINS/DAMAGED
INTERIOR

The carpet was stained and damaged in areas in the interior. A qualified contractor should evaluate and repair or replace as necessary.

4.3.2 – Floors
Floors 3
FLOOR-HUMP
INTERIOR

The floor had a noticeable hump or rise in areas in the interior. A qualified contractor should evaluate and repair or replace as necessary.

4.3.3 – Floors
Floors 4
Floors 5
Floors 6
SEAMS WIDE/INCONSISTENT
INTERIOR

The flooring had seams that were wide or inconsistent possibly indicating of loose flooring or poor installation.  A qualified contractor should evaluate and repair or replace as necessary.

4.3.4 – Floors
Floors 7
FLOOR DAMAGED
INTERIOR

The floor was damaged and or had blemishes at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.

4.4.1 – Doors
Doors 1
DOOR-NOT LOCKING
REAR ENTRANCE DOOR

The rear entrance door did not lock properly at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

4.9.1 – Smoke & CO Detectors
CO DETECTOR MISSING
INTERIOR

Carbon monoxide detectors were not installed within a specified distance of each room lawfully used, The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that have a fuel-burning heater or appliance, a fireplace, or an attached garage.

4.9.2 – Smoke & CO Detectors
SMOKE DETECTOR MISSING
INTERIOR

The smoke detectors were missing at the time of inspection. A qualified person should replace them as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.

 5 – Bathroom
5.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH
BATHROOM 1

The countertop needs caulking with silicone along the backsplash.  A qualified contractor should evaluate and repair or replace as necessary.

5.8.1 – Plumbing Fixtures
Plumbing Fixtures 1
NOT WORKING SINK
BATHROOM

The sink was not working/producing water at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

5.9.1 – Toilets
Toilets 1
TOILET RUNS
BATHROOM 1

The toilet continually “runs” after flushing. This generally means the interior tank components are not working properly. A qualified contractor should evaluate and repair or replace as necessary.

 6 – Bathroom 2
6.5.1 – Cabinets & Counters
Cabinets & Counters 1
CAULKING – BACKSPLASH
BATHROOM 2

The counter top needs caulking with silicone along the backsplash.  A qualified contractor should evaluate and repair or replace as necessary.

6.8.1 – Plumbing Fixtures
Plumbing Fixtures 1
LEAK – SINK CONTROL VALVE
BATHROOM 2

A control valve at the sink was leaking during operation at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

6.11.1 – Fixture Valve Installation And Temperature
Fixture Valve Installation And Temperature 1
WATER NOT HOT
BATHROOM 2

The hot water at the sink did not get over 100 degrees whereas the nearby faucets did. A qualified contractor should evaluate and repair or replace as necessary.

 7 – HVAC Packaged Unit
7.1.1 – System Information
System Information 1
BEYOND TYPICAL LIFE EXPECTANCY
RTU #1

Due to the year of manufacture (1984), the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate and repair or replace as necessary.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

7.6.1 – Cabinet
Cabinet 1
CORRODED, RUSTED
RTU #1

The heating system cabinet was corroded, rusted, or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

7.7.1 – Condensate
Condensate 1
DISCHARGE TOO SHORT
RTU #1

The condensate discharge pipe should be extended so that the water is diverted to a proper drain or to a proper distance away from the building and foundation. A qualified contractor should evaluate and repair or replace as necessary.

7.8.1 – AC Compressor
AC Compressor 1
COIL FINS DAMAGED
RTU #1

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

7.8.2 – AC Compressor
AC Compressor 2
RUSTED COMPONENTS
RTU #1

Interior components showed rust in areas. A qualified contractor should evaluate and repair or replace as necessary.

7.15.1 – Cooling System Operation
THE COOLING SYSTEM DID NOT OPERATE
RTU #1

The cooling system did not operate at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.

7.16.1 – Heating System Ignition & Operation
SHORT CYCLING
RTU #1

The heating system was short-cycling (repeated start-up and shut-down) at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.

 8 – HVAC Packaged Unit 2
8.1.1 – System Information
System Information 1
BEYOND TYPICAL LIFE EXPECTANCY
RTU #2

Due to the year of manufacture (1984), the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate and repair or replace as necessary.  InterNACHI’s Standard Estimate Life Expectancy Chart for Homes

8.6.1 – Cabinet
Cabinet 1
CORRODED, RUSTED
RTU #2

The heating system cabinet was corroded, rusted, or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.

8.7.1 – Condensate
Condensate 1
DISCHARGE TOO SHORT
RTU #2

The condensate discharge pipe should be extended so that the water is diverted to a proper drain or to a proper distance away from the building and foundation. A qualified contractor should evaluate and repair or replace as necessary.

8.8.1 – AC Compressor
AC Compressor 1
COIL FINS DAMAGED
RTU #2

There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

8.8.2 – AC Compressor
AC Compressor 2
RUSTED COMPONENTS
RTU #2

Interior components showed rust in areas. A qualified contractor should evaluate and repair or replace as necessary.

8.15.1 – Cooling System Operation
THE COOLING SYSTEM DID NOT OPERATE
RTU #2

The cooling system did not operate at the time of inspection. A qualified contractor should evaluate and repair/replace as necessary.

8.16.1 – Heating System Ignition & Operation
HEATING SYSTEM IS NOT OPERATIONAL
RTU #2

The heating system did not respond to the demand heat or did not function properly at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.

 10 – Electrical
10.2.1 – Distribution Panels
Distribution Panels1
SCREWS MISSING – PANEL COVER
ELECTRICAL PANEL

Screws/fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Water Heating Equipment
12.1.1 – General Information
General Information 1
OLDER THAN 10 YEARS
WATER HEATER

The water heater (1985) was at or beyond its warranty and/or expected life expectancy.

The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.

12.2.1 – Water Shut-Off & Pipe Connections
Water Shut-Off & Pipe Connections 1
CORRODED – PIPE FITTINGS
WATER HEATER

Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

12.12.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE HIGH
WATER HEATER

The water temperature was higher than the acceptable range of 120-130 degrees. Recommend adjusting the water heater thermostat. A qualified contractor should evaluate and repair or replace as necessary