The roof was actively leaking during the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
Wall flashing appears to be improperly sealed in areas. This may allow moisture intrusion of the exterior walls. A qualified contractor should evaluate and repair or replace as necessary.
A plumbing vent was cracked/damaged in areas. A qualified contractor should evaluate and repair or replace as necessary.
There were signs of moderate cracking in the parking lot areas. A qualified contractor should evaluate and repair or replace as necessary.
Minor cracking/signs of repair were visible at the walkway at the front of the uit. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary.
There were penetrations in areas of the siding at the time of inspection. Recommend applying the appropriate sealant to these areas to prevent potential moisture or pest intrusion. A qualified contractor should further evaluate and repair or replace as necessary.
The ceilings showed evidence that moisture was entering from behind including damage and deterioration at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The ceiling tiles showed some moderate staining indicating moisture intrusion did or does still exist in multiple areas throughout the unit. A qualified contractor should evaluate and repair or replace as necessary.
Baseboard trim was missing in areas of the interior walls at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The mirror was cracked/damaged in areas in the interior. A qualified contractor should evaluate and repair or replace as necessary.
The carpet was stained and damaged in areas in the interior. A qualified contractor should evaluate and repair or replace as necessary.
The floor had a noticeable hump or rise in areas in the interior. A qualified contractor should evaluate and repair or replace as necessary.
The flooring had seams that were wide or inconsistent possibly indicating of loose flooring or poor installation. A qualified contractor should evaluate and repair or replace as necessary.
The floor was damaged and or had blemishes at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.
The rear entrance door did not lock properly at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
Carbon monoxide detectors were not installed within a specified distance of each room lawfully used, The inspector recommends the installation of carbon monoxide detectors in appropriate locations. Colorado House bill 1091 became effective on July 1, 2009, which requires Carbon Monoxide detectors to be installed in most properties that have a fuel-burning heater or appliance, a fireplace, or an attached garage.
The smoke detectors were missing at the time of inspection. A qualified person should replace them as needed. The existing smoke detectors were tested if present, but they are only noted as to presence and operation as of the date of inspection. Smoke detectors may work today but not work when you need them to work. This is why it is important for you to test them on a regular basis, monthly at least. Smoke detectors are recommended by the U.S. Product Safety Commission to be installed inside each bedroom and adjoining hallway and on each living level of the property and basement level.
The countertop needs caulking with silicone along the backsplash. A qualified contractor should evaluate and repair or replace as necessary.
The sink was not working/producing water at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The toilet continually “runs” after flushing. This generally means the interior tank components are not working properly. A qualified contractor should evaluate and repair or replace as necessary.
The counter top needs caulking with silicone along the backsplash. A qualified contractor should evaluate and repair or replace as necessary.
A control valve at the sink was leaking during operation at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The hot water at the sink did not get over 100 degrees whereas the nearby faucets did. A qualified contractor should evaluate and repair or replace as necessary.
Due to the year of manufacture (1984), the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate and repair or replace as necessary. InterNACHI’s Standard Estimate Life Expectancy Chart for Homes
The heating system cabinet was corroded, rusted, or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.
The condensate discharge pipe should be extended so that the water is diverted to a proper drain or to a proper distance away from the building and foundation. A qualified contractor should evaluate and repair or replace as necessary.
There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
Interior components showed rust in areas. A qualified contractor should evaluate and repair or replace as necessary.
The cooling system did not operate at the time of inspection. A qualified contractor should evaluate and repair or replace as necessary.
The heating system was short-cycling (repeated start-up and shut-down) at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.
Due to the year of manufacture (1984), the heating system is assumed to be near the end of its expected service life. Regular maintenance and monitoring of its condition are recommended. Budgeting for repairs and future replacement is recommended. A qualified contractor should evaluate and repair or replace as necessary. InterNACHI’s Standard Estimate Life Expectancy Chart for Homes
The heating system cabinet was corroded, rusted, or damaged in some areas. A qualified contractor should evaluate and repair or replace as necessary.
The condensate discharge pipe should be extended so that the water is diverted to a proper drain or to a proper distance away from the building and foundation. A qualified contractor should evaluate and repair or replace as necessary.
There was damage to the air-conditioner condenser coil fins. This limits the ability to dissipate heat. Further damage to the coil fins should be avoided in order to maintain cooling system efficiency and avoid problems from overheating of the compressor. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
Interior components showed rust in areas. A qualified contractor should evaluate and repair or replace as necessary.
The cooling system did not operate at the time of inspection. A qualified contractor should evaluate and repair/replace as necessary.
The heating system did not respond to the demand heat or did not function properly at the time of the inspection. A qualified contractor should evaluate and repair or replace as necessary.
Screws/fasteners were missing at the electrical panel cover. A qualified contractor should evaluate and repair or replace as necessary.
The water heater (1985) was at or beyond its warranty and/or expected life expectancy.
The water heater age was determined by the photo included in this report. According to the U.S. Department of energy, these major appliances are intended to run for between 8 and 12 years. Be advised that every water heater will age differently relative to the following life span factors: water quality, mineral buildup, frequency of flushing, the volume of water utilized, size of tank, brand, and quality of water heater. Although it was operating at the time of the inspection, the inspector can not determine the remaining life of the water heater.
Pipe fittings at the water heating equipment were corroded. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
The water temperature was higher than the acceptable range of 120-130 degrees. Recommend adjusting the water heater thermostat. A qualified contractor should evaluate and repair or replace as necessary