5 – Exterior


Minor cracking was visible on the driveway in some areas. Monitoring is the minimum recommendation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
Recommend a qualified contractor should evaluate and repair or replace as needed.





The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazards and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.




The vertical distance between the photo-eye beam and the floor should be no more than 6 inches.

Although GFCI protection of garage circuits may not have been required at the time in which this property was built, GFCI protection is now required for all 15- and 20-amp receptacles in a garage, including outlets for refrigerators, sprinkler systems, garage door openers, and washing machines – some items may not be protected on purpose due to the potential for them to go unnoticed and cause damage.
NAIL POPS-CEILINGS




The window appeared to have a broken seal that has been compromised. Condensation and/or cloudiness between the two panes of glass were observed. This will have a negative impact on energy efficiency. Also, because there is moisture between the panes with no ventilation, mold can eventually develop. A qualified contractor should evaluate and repair or replace as necessary.

The window had a cracked or broken glass pane. A qualified contractor should evaluate and repair or replace as necessary.





An interior door did not latch properly. This may be that it was not shimmed properly at the jamb (too wide) or the strike plate was not in the correct position.
A qualified contractor should evaluate and repair or replace as necessary.
Carpeting was used as a floor covering material in the tub, shower, and/or toilet areas. The carpet is bound to get wet from steam/vapor from the shower, splashing, and water dripping off a body. Carpet tends to act as a sponge and soak up the moisture, which gives mildew and molds an opportunity to grow and spread. Recommend a qualified contractor to evaluate and replace the floor covering materials as needed.

The tile floor had missing or damaged grout. A qualified contractor should evaluate and repair or replace as necessary.
There was a leak at the shower head connection at the time of inspection. Recommend a qualified contractor to evaluate and repair or replace as necessary.
A control valve at the sink was leaking during operation at the time of inspection.
A qualified contractor should evaluate and repair or replace as necessary.

The property contained a pit for a sump pump, but no pump was installed. The water level in the sump pit at the time of the inspection was higher than what is considered acceptable. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.
A sump pump system protects the property from water intrusion by discharging rising groundwater or by routing surface drainage via the property perimeter drain to the pit, from where it is discharged by the pump to the exterior of the property or to a waste pipe or storm drain. Sump pumps require periodic maintenance to ensure that they work when they’re needed and should be tested on an annual basis to ensure they are in working order. The pumps can be tested by lifting the float, but to avoid potential shock/electrocution hazards testing should be performed using a tool that will not conduct electricity. Pumps have a filter that should be cleaned during routine maintenance.


Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.