2 – Roof
2.7.1 – Roof Drainage Systems
Roof Drainage Systems 1
DEBRIS IN GUTTERS

Gutters were full of debris or granules in areas and need to be cleaned. The debris in gutters can clog drainage, or be sign gutters are sloped improperly – Either of which may cause problems by overflowing to introduce excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement.

Debris in gutters can also conceal rust, deterioration, or leaks that are not visible until cleaned.

A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 3 – Attic, Insulation, and Ventilation
3.1.1 – Attic Access
NEEDS FRAMING

How to catch is held up by a couple of nails. Trim to support the attic hatch should be installed to keep it in place and make it removal safe. I qualified contractor should be returning to make a recommendation

3.6.1 – Electrical Wiring In Attic
Electrical Wiring In Attic 1
JUNCTION BOX MISSING COVER PLATE

The splice/Junction box was missing a cover plate. A qualified contractor should evaluate and repair or replace as necessary.

 5 – Exterior
5.11.1 – Walkways
Walkways 1
CRACKING – MODERATE

There were signs of moderate cracking on the walkway(s) in areas. Cracks that progress to a separation of 1/4″ and more would be an indication of settlement, heaving, or structural problems. Cracks may present a tripping hazard. A qualified contractor should evaluate and repair as necessary.

5.14.1 – Exterior Faucets (Hose Bibs)
Exterior Faucets (Hose Bibs) 1
COULDN’T REMOVE THE GARDEN HOSE
FRONT

The outside water faucet is connected to a garden hose. The hose could not be removed to inspect the faucet’s current operation. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

5.21.1 – Roof Drainage – Downspouts & Extensions
Roof Drainage - Downspouts & Extensions 1
RECONNECT EXTENSION

The downspout (s) need to have extensions reconnected. This condition may cause problems by introducing excessive amounts of moisture to the soil beneath the foundation. Excessive moisture in the soil supporting the foundation can affect its ability to support the weight of the structure above and may cause foundation damage from soil movement. When moisture is introduced to the foundation it could also cause possible mold growth. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 6 – Attached Garage
6.2.1 – Occupant Door
Occupant Door 1
NOT SELF CLOSING
2ND FLOOR

The door between the garage and the living space failed to close by itself. Modern safety requirements require that the door between the home interior and the garage be self-closing for safety reasons related to fire hazards and toxic fumes. A qualified contractor should evaluate and repair or replace as necessary.

6.13.1 – Stairs & Railings
Stairs & Railings 1
SPINDLE SPACING OVER 4”

Improper spacing was noted between balusters, spindles, and rails. This is a safety hazard, especially for small children.

Guards may not allow the passage of a sphere 4 inches in diameter.

Correction and further evaluation are recommended.

 7 – Interior, Doors, Windows
7.4.1 – Doors
Doors 1
DAMAGED – DOOR
PRIMARY BEDROOM

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

7.8.1 – Stairways & Railings
Stairways & Railings 1
NO RETURN AT ENDS

At the interior stairs, the handrail had a railing end that did not return to the wall or post.  A fall could occur if something (purse, backpack, etc.) caught the end of the railing when descending. A fall or injury could occur if not corrected. A qualified contractor should evaluate and repair or replace as necessary.

7.12.1 – Bar Sink Outlets
Bar Sink Outlets 1
MISSING FACE PLATE

The outlet under the sink in the mother-in-law suite kitchen is missing a face plate. Because this is a high moisture area it is especially important to have one installed.

7.14.1 – Fireplace Wood-Burning
Fireplace Wood-Burning 1
DEFECT AT DAMPER DOOR

The fireplace had a defect at the damper door. A qualified contractor should evaluate and repair or replace as necessary.

 8 – Kitchen
8.5.1 – Cabinets & Counters
Cabinets & Counters 1
GROUT – COUNTERTOP

The countertop tiles had missing or damaged grout.  A qualified contractor should evaluate and repair or replace as necessary.

8.6.1 – Electrical Outlets
Electrical Outlets 1
Electrical Outlets 2
GFCI-NOT ALL PROTECTED

Ground fault circuit interrupter (GFCI) Protection was not provided for all kitchen electrical outlets. Although GFCI protection of kitchen outlets may not have been required at the time in which this property was built, as general knowledge of say fielding practices has improved with the passage of time building standards have changed to reflect current understanding.  A qualified contractor should evaluate and repair or replace as necessary.

8.6.2 – Electrical Outlets
Electrical Outlets 3
FACEPLATE MISSING

An electrical outlet had a missing faceplate. A qualified contractor should evaluate and repair or replace as necessary.

8.13.1 – Dishwasher
Dishwasher 1
NO HIGH LOOP

The dishwasher drain line came out from a low location and did not discharge into a higher drain pipe. Dishwasher drain lines require a “high loop” in the line in order to drain properly. A “high loop” may have been hidden behind the appliance itself. The high loop in the drain hose is to keep water from settling in the hose to prevent any odors from backing up into the dishwasher. Food or debris may become stuck in the line and smell or mold if not corrected. Recommend a qualified contractor to evaluate and repair or replace as needed.

 10 – Bathroom
10.2.1 – Doors
Doors 1
DAMAGED – DOOR
2ND FLOOR BATHROOM

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.1 – Drain Waste and Vent System
Drain Waste and Vent System 1
NOT WORKING – SINK STOPPER
2ND FLOOR BATHROOM RIGHT SINK

The drain stop did not work or did not hold water in the sink.  A qualified contractor should evaluate and repair or replace as necessary.

10.10.2 – Drain Waste and Vent System
Drain Waste and Vent System 2
NOT WORKING – TUB STOPPER
2ND FLOOR BATHROOM

The drain stop did not work or did not hold water in the tub.  A qualified contractor should evaluate and repair or replace as necessary.

 11 – Bathroom 2
11.2.1 – Doors
Doors 1
DAMAGED – DOOR

The door surface was damaged.  A qualified contractor should evaluate and repair or replace as necessary.

11.7.1 – Electrical Outlets
Electrical Outlets 1
OUTLET HOT AND NEUTRAL REVERSED
PRIMARY BATHROOM

One or more electrical outlet(s) were wired incorrectly with the hot and neutral wires being reversed. While the outlet still provides power to electronic equipment, a shock hazard has been created as there is still electricity running through the hot wire when the switch is off. A qualified contractor should evaluate and repair or replace as necessary according to current standards.

11.9.1 – Cabinets & Counters

Cabinets & Counters 1

Cabinets & Counters 2

CAULKING – SINK
PRIMARY BATHROOM

The countertop needs caulking with silicone around the sink.  A qualified contractor should evaluate and repair or replace as necessary.

11.16.1 – Water Supply Functional Flow
Water Supply Functional Flow 1
Water Supply Functional Flow 2
PRESSURE DROP
PRIMARY BATHROOM

With at least 2 plumbing fixtures running water, there was a noticeable drop in the water flow after the toilet was flushed. A qualified contractor should evaluate and repair or replace as necessary.

 12 – Bathroom 3
12.4.1 – Ceilings & Walls
Ceilings & Walls 1
MOISTURE STAINING-CEILINGS
1ST FLOOR HALL BATHROOM

The ceiling showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

 13 – Bathroom 4
13.4.1 – Ceilings & Walls
Ceilings & Walls 2
Ceilings & Walls 3
MOISTURE STAINING-WALLS
1ST FLOOR BATHROOM EN SUITE

The wall showed wet staining indicating moisture intrusion did or does still exist.  A qualified contractor should evaluate and repair or replace as necessary.

 14 – Plumbing
14.1.1 – Main Water Shut-Off Valve
CORRODED – VALVE

The main water shutoff valve was corroded.

The valve is not and was not operated during the scope of a home inspection.

Recommend a qualified contractor should evaluate and repair or replace as necessary.

 15 – Electrical
15.2.1 – Distribution Panels
Distribution Panels 1
MISSING – CIRCUIT LABELS

The circuit labels were missing, partial, or illegible at the electrical distribution panel. The circuit labels provide information describing the locations each individual circuit breaker provides power to.

Recommend a qualified contractor to verify the breakers and accuracy of any existing labeling as necessary.

 16 – Indirect Fired Water Heater
16.3.1 – Expansion Tank / Valve
Expansion Tank / Valve 1
NOT SECURED

The expansion tank was not properly secured. A qualified contractor should evaluate and repair or replace as necessary.

16.4.1 – Water Temperature
Water Temperature 1
WATER TEMPERATURE LOW

The water temperature was below the suggested range of 120-130 degrees. Recommend adjusting the water heater thermostat first. If water does not reach the acceptable range then a qualified contractor should evaluate and repair or replace it as necessary.

 17 – Heating – Furnace
17.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

17.10.1 – Blower
Blower 1
BLOWER WHEEL DIRTY

The blower motor and/or wheel appeared to be dirty at the time of inspection. Blower fan motors and fan wheels are subjected to constant dirt, dust, and lint and can become overly dirty when not cleaned on a regular basis and even faster if the air filters are not changed regularly.

A qualified contractor should evaluate, clean, and service as necessary, and certify the unit is in good working order.

 18 – Heating – Boiler
18.1.1 – Heating System Information
SERVICING RECOMMENDED

Based on the age of the heating system it is recommended that it be cleaned and serviced and certified (if possible) by an HVAC professional.

 19 – Cooling
19.2.1 – AC Refrigerant Lines
AC Refrigerant Lines 1
AC Refrigerant Lines 2
MISSING INSULATION

The air-conditioner refrigerant suction line (large, insulated) has damaged or missing insulation in areas. A qualified contractor should evaluate and repair/replace as necessary.

19.3.1 – AC Compressor
AC Compressor 1
AC Compressor 2
UNIT IS NOT LEVEL

The exterior compressor unit was not level. Over time, this may result in noisy fan operation, damage to the fan bearings, and a shortened fan lifespan, or it may result in movement of the compressor housing which can cause leaks in refrigerant lines resulting in expensive service. A qualified contractor should evaluate and repair or replace as necessary and according to current standards.

 20 – Well Water
20.3.1 – Well Components Inspected
Well Components Inspected 1
Well Components Inspected 2
WELL COMPONENT DEFECT

The following defects were noted with the good system or component(s):

Corrosion at Valves

Excessive condensation on the tank.

A qualified well technician should evaluate and repair or replace as necessary and according to current standards.